Contacts, documents and full notice history are available with a subscription.
Special Notice Expired 1 notice 1 document

J045--HVAC Refurbishment and Restoration (21 units) at Captain James Lovell FHCC Intent to Sole Source 36C25225Q0453

Solicitation 36C25225Q0453 Copied Notice ID c75370aba09a407d9c28d9231f5fb4d6 Copied VETERANS AFFAIRS, DEPARTMENT OF — 252-NETWORK CONTRACT OFFICE 12 (36C252)
SAM.gov
Posted
Jun 06, 2025
Deadline
Jun 11, 2025
Set-aside
None
NAICS
238220
PSC
J045

Summary

AI-generated · Aug 24, 2025

A sole-source, firm-fixed-price contract is sought for refurbish and maintenance of 21 HVAC air handler units at Captain James Lovell FHCC in North Chicago, IL. The selected vendor must perform ATP testing to verify cleanliness and compliance with NFPA 90A, OSHA, TJC, and VA standards, with AHRI guidance for ATP testing. Work includes de-energizing and isolating AHUs, sealing adjacent ductwork, and using air scrubbers, followed by surface cleaning, removal of non-compliant coatings/foams, reinforcing damaged areas with steel, and applying a sequence of coatings (epoxy, fire barrier, antimicrobial topcoat, and MVS) to restore integrity and prevent leaks, corrosion, and microbial growth. Coil restoration and pre- and post-restoration ATP testing must be conducted, and proper operation of drains/traps confirmed prior to re-commissioning. A detailed installation report including differential pressure readings and ATP results must be generated.

This notice is not a request for competitive quotes; no solicitation documents are available and phone requests will not be honored. Firms that believe they can meet the requirements should submit information about their products and services, plus references from other customers, to the Contracting Officer by the stated deadline.

Under Statutory Authority 41 U.S.C. 1901 the VA Great Lakes Acquisition Center (GLAC) intends to negotiate a sole source contract AIR QUALITY INNOVATIVE SOLUTIONS LLC for Refurbish and Maintenance Services on HVAC Air Handler Units (21 units) at the Captain James Lovell FHCC located in North Chicago, IL. This acquisition is conducted under the authority of FAR 8.405-6(a)(1)(b), Only one source is capable of providing the supplies or services required at the level of quality required because the supplies or services are unique or highly specialized. This will be a firm fixed price contract (one-time purchase) under NAICS 238220. The FHCC is looking for vendors who are capable of providing services that use ATP Testing to facilitate equipment to function in conformance with the latest published edition of National Fire Protection Association Code 90A (NFPA 90A), Occupational Safety and Health Administration (OSHA), Joint Commission (TJC), and Veterans Administration (VA) standards. ATP Testing in HVAC air handlers refers to the process of measuring the presence of adenosine triphosphate (ATP), which is an indicator of biological activity. This testing helps evaluate the cleanliness of air conditioning systems by detecting the presence of active organic matter, such as bacteria and viruses, which can indicate potential contamination. ATP testing is crucial for ensuring the sanitation of HVAC systems, particularly in environments where hygiene is critical, such as hospitals and food facilities. Standards for ATP testing is set by the Air Conditioning, Heating and Refrigeration Institute (AHRI). FHCC is looking for vendors to: Coordinate with the facility to de-energize AHUs. Isolate air handling unit by sealing off adjacent ductwork and using air scrubbing machines. Clean and prepare all surfaces that will be addressed by the contractor including the removal of non-compliant coatings and foams. Reinforce compromised surfaces with steel as needed to restore structure. Apply CPR-SL Epoxy (self-leveling) at 3/16 nominal thickness and 6 up walls throughout all chamber floors & condensate pans to stop leaks and halt corrosion. Apply Fire Barrier over all epoxy for compliance with NFPA 90A fire code. Apply Antimicrobial Topcoat over all fire barrier to ensure watertight surface and provide an active antimicrobial surface. Apply MVS (Multi-acrylic, corrosion resistant, antimicrobial coating) on walls, ceiling, fan housing & structural steel. Conduct Coil Restoration on all coils for the removal of biofilm and debris Once coil restoration is complete, Contractor must perform pre & post restoration ATP Testing to measure microbial activity on the cooling coil both before and after and coil restoration. Confirm proper operation of existing drains and traps prior to re-commissioning. Generate a detailed Installation Report which includes results from differential pressure readings and ATP Testing This Notice of Intent is not a request for competitive quotes. No solicitation documents are available and telephone requests will not be honored. However, if a firm believes it can meet the requirements it must furnish information about its products and services, as well as references from other customers who are using these products and service to the Contracting Officer by Wednesday 06/11/2025 at 10:00am. Supporting evidence must be furnished in sufficient detail to demonstrate the ability to comply with the above requirements.

From Special Notice posted on Jun 06, 2025

Notice history

1
  1. Special Notice LATEST Posted Jun 06, 2025 View

Details

Solicitation number 36C25225Q0453
Notice ID c75370aba09a407d9c28d9231f5fb4d6
Notice type Special Notice
Product / Service (PSC) J045
NAICS 238220
Archive date Aug 10, 2025

Award Information

Awardees
0

Documents

1
View on SAM.gov

Contacts

primary
Lemke, Justin

Contract Specialist

Email

Phone

Agency

VETERANS AFFAIRS, DEPARTMENT OF
VETERANS AFFAIRS, DEPARTMENT OF
252-NETWORK CONTRACT OFFICE 12 (36C252)

Place of Performance

Dates

Posted Jun 06, 2025 1 year ago
Last Updated Aug 06, 2026 2 days ago
Due Jun 11, 2025 1 year ago