J045--Boiler Plant Services for the Greater Los Angeles VA Healthcare System 36C26226Q0383
Summary
AI-generated · Feb 27, 2026Contractor will perform boiler plant tuning, testing, and preventative maintenance services for the Greater Los Angeles VA Healthcare System. Work includes tuning and testing of boiler/CEM control systems and routine preventative maintenance to keep the plant reliable and compliant. The contract will be firm-fixed-price, a site visit is authorized with details posted in the solicitation, and bidders must be SDVOSB-certified; responses to the solicitation are required and telephone responses are not accepted.
Since the presolicitation, a formal solicitation has been issued outlining the same service scope. A site visit remains available, and the solicitation will specify the SDVOSB certification requirement. The awards section shows no contracts issued yet (two placeholders with zero amounts), indicating no awards have been made to date.
This is not a solicitation announcement. This is a pre-solicitation notice only. The purpose of this notice is to announce that the Department of Veterans Affairs, Veterans Integrated Service Network (VISN 22), Network Contracting Office (NCO) 22 is seeking contractors interested in providing a quote for the Boiler/CEM Testing, Tuning and Preventative Maintenance Services at the Greater Los Angeles VA Healthcare System, 11301 Wilshire Blvd., Los Angeles CA, 90073. Solicitation shall be issued on or about February 26, 2026. The following NAICS code: 238220 and PSC code: J045 apply to this requirement. This is a 100% Service-Disabled Veteran Owned Small Business (SDVOSB) set-aside. This will be a firm-fixed price contract. A site visit will be authorized for this requirement; details will be posted in the solicitation. ALL SDVOSB s MUST BE CERTIFIED WITH THE GOVERNMENT. All interested parties must respond to the solicitation announcement. A response to this notice is not a request to be added to a prospective bidders list or to receive a copy of the solicitation. Telephone responses will not be accepted. Point of Contact for this announcement is Jennell Christofaro at jennell.christofaro@va.gov.
From Presolicitation posted on Feb 26, 2026This requirement is for the boiler plant tuning, testing, and preventative maintenance services for the Greater Los Angeles VA Healthcare System.
From Solicitation posted on Feb 26, 2026Contractor Inquiries Boiler Plant Services Solicitation Are new gaskets for manways, handholes, and doors provided by the VA or contractor for the annual internal inspections on the boilers and DA Tank & Condensate tank? All Gaskets are to be provided by the contractor If the inspector identifies deficiencies during the internal or external inspections, is the contractor responsible for repairing them under this contract or will the VA want a quote submitted to them for deficiencies and approval? The VA will want a quote to repair. Are confined space ventilation systems provided by the VA for internal inspections? No. Contractors must provide all equipment necessary for confined space entry. Are replacement parts beyond consumables covered under this contract or funded separately? Any parts not specifically stated in the SOW would be funded separately. For repairs, if a major component fails (valve actuator, analyzer, PLC module), will the government issue a separate repair order? The VA will want a quote to repair. May boilers be tested back to back for safety device testing in a week, while still maintaining the N+1. For example, Boiler 1 is tested Monday, then Boiler 2 Tuesday, Boiler 3 Wednesday, etc? Yes. If the boilers are allowed to be tested in a single week, can the plant warm up all the boilers prior to a scheduled site visit, if 2 weeks of advance notice is given? If boilers are operational, they can be warmed up, etc. at any time. Are weekends and nights permitted for work with prior approval? Maybe. Times of day and day of week are flexible depending upon operational requirements. This would be determined by the COR or designee on a case-by-case basis. Does the site have passwords and codes for HMI access on the boilers for combustion tuning and adjustments? Yes. During the site visit the Deaerator Tank was noted as having current leaks and needs parts of the shell replaced. Is the VA having a separate contract to repair this or is this part of this solicitation? There is nothing wrong with the deaerator tank. The leaking tank is the condensate tank. The repair of the condensate tank is not part of this solicitation.
From Solicitation posted on Mar 10, 2026Notice history
4-
-
Solicitation Posted Feb 26, 2026View changes (4)
- Description: Description was updated
- Notice Type: Presolicitation → Solicitation
- Response Deadline: Feb 26, 2026 → Mar 24, 2026
- Set-Aside: Service-Disabled Veteran-Owned Small Business Set Aside → None
-
Award Notice LATEST Posted Apr 20, 2026
Details
Award Information
Awardees
| Company Name | UEI | CAGE Code | Location |
|---|---|---|---|
| KSC FEDERAL CONTRACTORS LLC | VRTRAALH2RX6 | 7XQ51 | WILDWOOD |
Contacts
Contracting Specialist
Agency
Place of Performance
NCO 22 - Network Contracting 3601 S. 6th Avenue
Tucson, AZ 85723