IDIQ for UPLC Columns and Quechers Kits for all FSIS labs 123A9425Q0052
Summary
AI-generated · Sep 27, 2025A 1-year IDIQ is being solicited to supply three analytical UPLC columns (two C18 variants and one C8 variant) and one type of QUECHERS sorbent kit for FSIS laboratories. The three analytical columns include: (1) a 50 mm x 3 mm C18 column with TMS endcapping, 1.7 μm particles, and a 100 ? pore size; (2) a 150 mm x 2.1 mm C18 column with iso-butyl side chains and TMS endcapping, 1.7 μm particles, and a 100 ? pore size; and (3) a 50 mm x 2 mm C8 column with TMS endcapping, 3 μm particles, and a 100 ? pore size. The QUECHERS kit is a pre-weighed WCX sorbent kit, 500 mg per tube in a 50 mL tube, with 55 μm particles and 70 ? pore size. Please refer to attached documents for additional specifications.
Q&A clarifies this is not a brand-new contract—there was a previous incumbent performing these services, though the government will not disclose the vendor. The government indicates no separate solicitation will be issued beyond this combined synopsis/solicitation, and interested bidders may use FOIA requests if they need the prior contract information.
This is a combined synopsis/solicitation for commercial supplies and services prepared in accordance with the format in FAR 12.6 as supplemented with FAR 13 and additional information included in this notice. The incorporated provisions and clauses are those in effect through Federal Acquisition Circular (FAC) 2025-5. THIS ANNOUNCEMENT CONSTITUTES THE ONLY SOLICITATION AND A SEPARATE SOLICITATION WILL NOT BE ISSUED. -------------------------------------------- This is for a 1-year IDIQ. Specifications are below: The Contractor shall provide all three types of Analytical UPLC columns and one type of QUECHERS sorbent kits based on the specifications listed below: Analytical UPLC Columns: Product Type: Analytical UPLC column Stationary phase: C18 with TMS endcapping Length: 50 millimeters Internal Diameter: 3 millimeters Particle size: 1.7 m Pore Size: 100 ? 2. Product Type: Analytical UPLC column Stationary phase: C18 with iso-butyl side chains and TMS endcapping Length: 150 millimeters Internal Diameter: 2.1 millimeters Particle size: 1.7 m Pore Size: 100 ? 3. Product Type: Analytical HPLC column Stationary phase: C8 with TMS endcapping Length: 50 millimeters Internal Diameter: 2 millimeters Particle size: 3 m Pore Size: 100 ? QUECHERS Sorbent Kits: Product Type: Pre-weighed QUECHERS kit Stationary phase: Weak Cation Exchange (WCX) Weight: 500 milligrams/tube Tube Volume: 50 milliliters Particle size: 55 micrometers Pore Size: 70 ? Please see attached documents for more information.
From Combined Synopsis/Solicitation posted on Sep 23, 2025Below is the Q&A Q1. We would like to know if this is a brand new contract OR if there is (was) an incumbent performing these services. If not brand new, could you please provide the current / previous contract number? A. There was a previous incumbent performing these services. The Government will not disclose the previous vendor or related information. You are encouraged to submit a FOIA request if you require this information. -------------------------------------------- This is a combined synopsis/solicitation for commercial supplies and services prepared in accordance with the format in FAR 12.6 as supplemented with FAR 13 and additional information included in this notice. The incorporated provisions and clauses are those in effect through Federal Acquisition Circular (FAC) 2025-5. THIS ANNOUNCEMENT CONSTITUTES THE ONLY SOLICITATION AND A SEPARATE SOLICITATION WILL NOT BE ISSUED. -------------------------------------------- This is for a 1-year IDIQ. Specifications are below: The Contractor shall provide all three types of Analytical UPLC columns and one type of QUECHERS sorbent kits based on the specifications listed below: Analytical UPLC Columns: Product Type: Analytical UPLC column Stationary phase: C18 with TMS endcapping Length: 50 millimeters Internal Diameter: 3 millimeters Particle size: 1.7 m Pore Size: 100 ? 2. Product Type: Analytical UPLC column Stationary phase: C18 with iso-butyl side chains and TMS endcapping Length: 150 millimeters Internal Diameter: 2.1 millimeters Particle size: 1.7 m Pore Size: 100 ? 3. Product Type: Analytical HPLC column Stationary phase: C8 with TMS endcapping Length: 50 millimeters Internal Diameter: 2 millimeters Particle size: 3 m Pore Size: 100 ? QUECHERS Sorbent Kits: Product Type: Pre-weighed QUECHERS kit Stationary phase: Weak Cation Exchange (WCX) Weight: 500 milligrams/tube Tube Volume: 50 milliliters Particle size: 55 micrometers Pore Size: 70 ? Please see attached documents for more information.
From Combined Synopsis/Solicitation posted on Sep 25, 2025Notice history
2-
Combined Synopsis/Solicitation Posted Sep 23, 2025
-
Combined Synopsis/Solicitation LATEST Posted Sep 25, 2025View changes (1)
- Description: Description was updated
Details
Award Information
Not yet awarded
Contacts
Agency
Place of Performance
USA