Contacts, documents and full notice history are available with a subscription.
Justification 1 notice 1 document

HOTD Extended Warranty Agreement CO-GEN 47PM0625C0001

Solicitation 47PM0625C0001 Copied Notice ID c2dded995fdb4f8e87f16c0155ff029a Copied GENERAL SERVICES ADMINISTRATION — PBS R11 BUILDING SERVICES DIVISION CENTER 2
SAM.gov
Posted
Sep 16, 2025
Deadline
No deadline
Set-aside
None
NAICS
561210
PSC
J035

Summary

AI-generated · Sep 17, 2025

Provide comprehensive extended warranty and preventive maintenance for HOTD’s two Taurus 60 turbine/generator sets at the Central Heating and Refrigeration Plant. The work includes scheduled turbine overhauls, generator reconditioning, and replacement of components with new or remanufactured OEM parts, plus four maintenance visits per year during which all control-system instrumentation, including fire and gas detection systems, are tested. Field service is performed by a local, highly skilled team supported by OEM design engineers to ensure safety, reliability, and technical accuracy, supporting continuous 24/7 operation of the plant that supplies steam, chilled water, and electricity to multiple federal buildings in the DC area.

This requirement is sole-source and brand-specific: Solar Turbines Incorporated is the proprietary manufacturer, installer, warranty holder, and service provider for the equipment, and the agency states that its minimum needs can only be satisfied by Solar Turbines Incorporated due to its unique capability to perform extended warranty/preventive maintenance on the two Taurus 60 units and related systems.

The General Services Administration Central Heating & Refrigeration Plant (HOTD) currently supplies steam and chilled water service to over 65 federal buildings in the District of Columbia , serving agencies such as the Department of Energy (DOE), Department of Agriculture (DOA), and Smithsonian Institute (SI). These services are a critical part of the customers daily operation. To guarantee that these customers receive steam and chilled water services without interruption, HOTD must continually maintain the plant s critical equipment. HOTD operates 24 hours a day, 365 days a year, and the reliability of the plant is important as it supports an operation of Federal and Quasi-Federal customers. HOTD uses natural gas to produce steam for the space comforts at the customer buildings and it operates two chillers to produce chilled water for the building year around. HOTD uses natural gas in a combine cycle mode, which first operates the gas turbines/electric generators and the turbine waste heat is then used in a boiler to produce steam. This combined cycle or co-generation also produces electricity for HOTD to avoid purchasing high priced electricity from the utility company. Average yearly savings are estimated over $5 million. The waste heat also increases boiler efficiency to result in additional savings. HOTD has invested several million dollars in the co-generation system to realize substantial savings and reduce pollution. The maintenance and operational support to operate this equipment was being performed for several years under the installation contractor, the Washington Gas Company, of which Solar Turbines Incorporated was the subcontractor and system manufacturer. The contractor shall provide comprehensive support for two Taurus 60 turbine/generator sets, encompassing scheduled turbine overhauls, generator reconditioning, and the replacement of components with new or remanufactured Original Equipment Manufacturer (OEM) parts as needed. The contract includes four maintenance visits per year, during which all instrumentation associated with the control system including fire and gas detection systems will be thoroughly tested. All field service work is performed by a highly skilled local team of qualified representatives, supported by OEM design engineers to ensure the highest standards of safety, reliability, and technical accuracy. Solar Turbines is the proprietary manufacturer, installer, warranty holder, and service provider of this equipment. The agency s minimum needs can only be satisfied by Solar Turbines Incorporated which has demonstrated a unique, innovative concept, and capability to perform extended warranty/preventive maintenance to the co-generation system, mainly consisting of two solar Taurus gas turbines, two generators and associated equipment at the Central Heating and Refrigeration Plant (HOTD).

From Justification posted on Sep 16, 2025

Notice history

1
  1. Justification LATEST Posted Sep 16, 2025

Details

Solicitation number 47PM0625C0001
Notice ID c2dded995fdb4f8e87f16c0155ff029a
Award number 47PM0625C0001
Notice type Justification
Product / Service (PSC) J035
NAICS 561210
Place of performance Washington, District of Columbia
Archive date Oct 16, 2025

Award Information

Awardees
0
Award Date
Aug 21, 2025

Documents

1
View on SAM.gov

Contacts

primary
TYLER ANDERSON

Email

secondary
Melvin Sloan

Email

Agency

GENERAL SERVICES ADMINISTRATION
PUBLIC BUILDINGS SERVICE
PBS R11 BUILDING SERVICES DIVISION CENTER 2

Place of Performance

Washington, District of Columbia 20407
USA

Dates

Posted Sep 16, 2025 10 months ago
Last Updated Aug 06, 2026 2 days ago
Awarded Aug 21, 2025 11 months ago