High-Performance Liquid Chromatography System 1164354

Solicitation 1164354 Copied Notice ID 34d7c0b6f2bc47368f5471be8a4fdf5c Copied AGRICULTURE, DEPARTMENT OF — USDA ARS AFM APD
SAM.gov
Posted
Mar 03, 2026
Deadline
Mar 13, 2026
Set-aside
None
NAICS
334516
PSC
6640

Summary

AI-generated · Mar 09, 2026

Seek a complete HPLC system with an electrochemical detector (ECD) including a computer, software, and installation. The package must include autosampler, degasser, multiple pumps or a gradient-capable pump, column oven and columns, detector, controller, and all necessary tubing and accessories with software to operate the system. All major flow-path components should be from the same manufacturer or fully supported by the same, and all flow-path tubing must be non-metal (PEEK preferred) to tolerate wide pH ranges (pH 1.0–14.0) with a minimum pressure tolerance of 20 MPa (2900 psi). The system should support constant flow or constant pressure modes, have pumps with ±2% flow accuracy and 0.06% precision, and include non-metal suction filters (ideally ceramic). The autosampler must control sample temperature 4–40 C, offer injection accuracy ±1% and injection variance <0.3%.

The detector must be an electrochemical detector (preferably with an Au electrode for sugars analysis) and either be from the same manufacturer or otherwise fully supported by them; the system should be modular to accommodate additional detectors in the future. Installation should include technical installation and initial testing, performed by a U.S. citizen. Additional features include remote monitoring, easy purging of mobile phases and baseline checks, auto-diagnostics with auto-recovery, a dual solvent delivery system, a degassing unit supporting up to three solvents, rapid injections for high-throughput analysis, high reproducibility with ultra-low carryover for micro-volume injections, automated sample preparation, automatic column information management (injection count and pressure), and monitoring of column degradation. The system should support advanced detection capabilities for carbohydrates using high-performance anion exchange chromatography with pulsed amperometric detection, and carry a warranty of at least 1 year (preferably 2+ years).

Description of Specifications - HPLC system with ECD, including computer, software, and installation: Minimum requirements for the HPLC system we require: The system should have all essential parts of an HPLC, to include: Autosampler, a degasser module, pumps, a column oven and columns, a detector, a controller, and all of the necessary tubing and accessories required to run the system, including the software necessary to connect to the controller and run the system. All major parts of the system (I.E. the pumps, detector, column oven, controller, etc.) should be from the same manufacturer or at least supported (as in troubleshooting support) by the same manufacturer. The parts of the system which lie within the flow path which carries the various buffers and samples through the system must not contain metal. No part of the flow path should contain stainless steel and all tubing used should consist of PEEK tubing, a hardy, non-reactive plastic tubing commonly used for various HPLC setups where metal is not possible due to the nature of the assayed samples and/or buffers necessary during analysis. PEEK tubing is required . The system and flow path must also be capable of enduring a wide range of pH, from 1.0-14.0, as many buffers used in our assays are at the extreme ends of the pH scale. Minimum pressure tolerance of at least 20 MPa (2900 psi) The system must have multiple pumps (at least 2), or at absolute minimum a single pump capable of generating gradients from multiple inputs. Specific non-detector potions of the system: The solvent delivery system should be able to operate in constant flow or constant pressure modes. The pumps must have a high flow rate accuracy (+ or - 2%) and precision (0.06%) The pumps should come equipped with a suction filter to prevent particulate contamination. As this will be in the flow path, it should be non-metal, ideally ceramic. The autosampler must provide temperature control to the sample compartment (between 4-40C minimum) The autosampler must have a high injection volume accuracy (+ or 1%) and low injection volume variance (<0.3%) The HPLC will require a specific type of detector called an electrochemical detector (ECD). The detector should either be manufactured by the same manufacturer as the other major parts, or at least be supported (as in Troubleshooting support) by the same manufacturer as the other major parts. The detector should also come with an Au (gold) electrode, as this is the electrode type needed for sugars analysis. The system is perferred to be modular and allow the installation of additional detectors in future. Any HPLC option considered should include technical installation and initial testing of the system;. The technician performing the installation is required to be a U.S. Citizen. Additional System Specifications: System Controller Supports remote monitoring Mobile phases can be purged and baselines checked easily via touch panel. Solvent Delivery Pump Auto-diagnostics to detect problems during analysis, and an auto-recovery function Duel solvent delivery system to reduce space Degassing Unit Can handle up to 3 degassed solvents Autosampler/Plate Changer Fast injection speed Continuous analysis of hundreds of samples High-reproducibility and ultra-low carryover for micro-volume injections Automated sample preparation functions Column Oven Automatic management of column information such as number of injections and pressure during analysis Monitoring of column degradation through usage history Electrochemical Detector Ability to detect carbohydrates using high-performance anion exchange chromatography with pulsed amperometric detection. There should be a warrantee of at least 1 year, and preferably 2 years or more, for the system.

From Sources Sought posted on Mar 03, 2026

Notice history

1
  1. Sources Sought LATEST Posted Mar 03, 2026 View

Details

Solicitation number 1164354
Notice ID 34d7c0b6f2bc47368f5471be8a4fdf5c
Notice type Sources Sought
Product / Service (PSC) 6640
NAICS 334516
Place of performance Madison, Wisconsin
Archive date Mar 28, 2026

Award Information

Not yet awarded

Documents

No files available

View on SAM.gov

Contacts

primary
Maria Thomas

Email

Agency

AGRICULTURE, DEPARTMENT OF
AGRICULTURAL RESEARCH SERVICE
USDA ARS AFM APD

Place of Performance

Madison, Wisconsin 53726
USA

Dates

Posted Mar 03, 2026 5 months ago
Last Updated Aug 06, 2026 1 day ago
Due Mar 13, 2026 4 months ago