HASKELL IHS - VESTIBULE DOORS, SIDELIGHTS, AND TRANSOMS REPLACEMENT IHS1512570
Summary
AI-generated · Aug 24, 2025Replace four exterior entry doors, four interior entry doors, and all associated sidelights and transoms for four vestibules. Exterior doors must be 42 inches wide with a full daylight panel (approximately 34x69) of UL 752 Level 5 bullet-resistant glazing or equivalent; all exterior glazing (doors, transoms, sidelights, exterior vestibule) requires UL Level 5, while interior glazing is tempered. Frames shall be black anodized aluminum, with commercial-grade LCN door closers, panic bars, heavy-duty continuous hinges with thresholds, and locks keyed to the facility master key. Exterior doors, sidelights, and transoms shall use mirror tint (minimum 35% shade) visible from the exterior, including the front exterior sliding door entrance; all four exterior doors must have awnings (black anodized aluminum) spanning the width of the exterior frame, not extending more than 36 inches from the building, and equipped with gutters and downspouts.
The northwest corner vestibule requires replacing two exterior glass panes with UL Level 5 bullet-resistant glazing; include a left-hand reverse exterior door (42x84) and a 4x42 transom (1/4 tempered) in the vestibule. The interior vestibule door to the Pediatric/Behavior Health area shall be a left-hand reverse 42x84 with two 8x100 sidelights and a 16x42 transom. Additional specified doors include a left-hand reverse exterior door and associated sidelights/transoms for the far west entry to the Medical Staff corridor, and right- and left-hand reverse exterior doors with corresponding sidelights/transoms for the south/southwest breezeway and the south entry near the kitchen, with exact sizes and configurations as described. Coordinate with the facility’s Secure Access Control provider to relocate wires, card readers, and electronically operated door strikes to their original or near-original locations for all replaced doors; ensure readers/strikes are functional before proceeding to the next exterior door.
1. PURPOSE OF THE PROJECT The Haskell Indian Health Center (HIHC), Indian Health Services (IHS) has a requirement for the replacement of (4) existing exterior entryway doors, (4) interior entryway doors, and the sidelights and transoms for all (4) vestibules. 2. DETAILED DESCRIPTION OF THE TECHNICAL REQUIREMENTS The interior and exterior doors shall be 42 wide to accommodate gurneys used by EMS and wide wheelchairs. All exterior doors shall have a full window/daylight panel measuring approximately 34 x 69 and be UL 752 Level 5 bullet resistant glazing or equivalent. All exterior glazing (door, transom, sidelights, exterior vestibule) shall be UL 752 Level 5 bullet resistant glazing or equivalent, except where noted in the scope of work. Interior glazing (door, transom, sidelights) shall be tempered glass. The northwest corner of the building has an existing metal and glass vestibule protruding from the building measuring approximately 36 out from the building and 64 wide. The (2) panes of glass on the exterior vestibule measure approximately 30 x 90 . These panes of glass shall be replaced with UL Level 5 bullet resistant glazing or equivalent. Within this vestibule there shall be a left hand reverse exterior door measuring 42 x 84 . The transom window shall be 4 x 42 and shall be 1/4 tempered glass. The interior door, leading from the vestibule to the Pediatric/Behavior Health (north) hallway, shall be a left hand reverse door measuring 42 x 84 with (2) sidelights measuring approximately 8 x 100 and a transom measuring approximately 16 x 42 . The far west entryway leading to the Medical Staff hallway shall have a left hand reverse exterior door measuring 42 x 84 with (2) sidelights measuring approximately 14 x 100 and a transom measuring approximately 16 x 42 . The interior door shall be a left hand reverse door measuring 42 x 84 with (2) sidelights measuring approximately 15 x 100 and a transom measuring approximately 16 x 42 . The south/southwest entryway in the breezeway between the Main Building and Wellness Center shall have a right hand reverse exterior door measuring 42 x 84 with (1) sidelight measuring approximately 13 x 101 and a transom measuring approximately 17 x 42 . The interior door shall be a right hand reverse door measuring 42 x 84 with (2) sidelights measuring approximately 5 x 100 and a transom measuring approximately 16 x 42 . The south entryway near the kitchen shall have a left hand reverse exterior door measuring 42 x 84 with (2) sidelights measuring approximately 15 x 100 and a transom measuring approximately 17 x 42 . The interior door shall be a left hand reverse door measuring 42 x 84 with (2) sidelights measuring approximately 15 x 100 and a transom measuring approximately 16 x 42 . Contractor shall coordinate with the facility s existing Secure Access Control provider (Cam-Dex Security Corp.) to remove and replace the wires, card readers, and electronically operated door strikes back to original locations or as close as possible for all replaced doors. Card readers and strikes shall be in good working order before starting on the next exterior door for security purposes and to justify egress. Door and window frames shall be black anodized aluminum and match the fit and finish of the current frames. All doors, interior and exterior, shall be equipped with a commercial grade LCN door closer, panic bar, heavy-duty continuous hinge with threshold, and lock keyed to the facility master key. All exterior doors, sidelights and transoms shall be tinted with a mirror tint that is reflective when viewed from the exterior. In addition, the same tint shall be applied to the front (east), exterior, automatic sliding door entrance. Tinting shall be minimum of 35% shade. All (4) exterior doors shall be equipped with awnings that span the width of the exterior frame to cover persons entering and exiting the building. The awnings shall be black anodized aluminum (or equivalent metal) to match the fit and finish of the exterior frames. The awnings shall not extend more than 36 away from the building. All awnings shall be equipped with gutters and downspouts to divert water away from the building.
From Solicitation posted on Jun 05, 2025Notice history
1-
Solicitation LATEST Posted Jun 05, 2025
Details
Award Information
Not yet awarded
Contacts
Phone
4059513771
Agency
Place of Performance
USA