H335--Underground Storage Tanks Testing and Inspection Services at Edward Hines, Jr. VA Hospital in Hines, IL 36C25226Q0450

Solicitation 36C25226Q0450 Copied Notice ID 446ad7603f0045caa95aa7da22d8094e Copied VETERANS AFFAIRS, DEPARTMENT OF — 252-NETWORK CONTRACT OFFICE 12 (36C252)
SAM.gov
Posted
May 04, 2026
Deadline
May 07, 2026
Set-aside
None
NAICS
541620
PSC
H335

Summary

AI-generated · May 05, 2026

Identify qualified sources capable of performing inspection, maintenance, testing, and limited repair of 19 diesel/unleaded storage tanks (USTs and ASTs) at Edward Hines Jr. VA Hospital, in accordance with federal, state, and local environmental regulations (including 40 CFR Part 280), with required Illinois OSFM certification and Illinois Class A/B/C UST credentials. Work includes reviewing records, maintaining tank documentation, coordinating compliance efforts with OSFM, evaluating maintenance/repair options with engineering staff, conducting on-site inspections, and delivering formal reports with findings and recommendations; ensure permits are current and displayed, and provide certification guidance as needed. The contractor must perform only limited maintenance within the certified scope and comply with applicable laws and programs (Energy Policy Act 2005, 40 CFR 280, VHA GEMS 7700, ISFM, and Illinois air quality regulations).

On-site inspections must be scheduled at least one week in advance and occur during normal work hours (7:00 am–3:30 pm, Monday–Friday). Inspections of all tanks require on-site verification by a certified Level A and B UST/AST Tank System Inspector and an Illinois-certified tank installer, with written and photo documentation if issues are found and a demonstration of real-time monitoring systems. Inspections follow a defined cadence: monthly (3rd–4th week), annual (October), and triennial (October) for USTs; annual (October) for ASTs. A closing meeting will review findings and regulatory deficiencies, and contractors must provide a formal report detailing conditions, recommended fixes, and required documentation (registrations, SPCC plans, inspections, manuals, permits, equipment IDs, and time on-site). Qualifications include five years’ relevant experience, three references (preferably with federal or Illinois government work), proof of Illinois Class A/B/C UST certification, and a prohibition on subcontracting; communications are to be with a self-performing contractor only. This is a sources-sought notice to assess capability and availability.

This is not a solicitation for proposals, proposal abstracts, bids, or quotations. The purpose of this notice is to obtain information regarding the availability and capability of all qualified sources to perform Siemens Uroskop De-Installation Services at Captain James A. Lovell Federal Health Care Center. Responses to the information requested will assist the Government in determining the appropriate acquisition method. It is understood that all firms submitting a response to this Sources Sought will have an established business in the industry of Underground Tank Testing and Inspection Services in accordance with requirements listed below. DESCRIPTION OF SERVICES Edward J. Hines Jr. VA hospital requires the services of a contractor for inspection, maintenance, testing, and repair services for nineteen (19) diesel/unleaded storage tanks located throughout the Hines VA Campus per 40 CFR Part 280. (16) Underground Storage Tanks (UST) (03) Above Ground Storage Tanks (AST) Overview of requirements The bidding contractors shall be certified by Office of the Illinois State Fire Marshall-(OSFM) & Illinois Class ABC certification Review historical records of tank performance Maintain Hines Storage Tank Records Coordinate Storage Tank compliance and permitting efforts with OSFM Work with engineering staff to evaluate maintenance and repair options Inspect tank system for compliance with federal, state, and local environmental regulations Provide formalized report on inspection and recommendations for each tank system Transmit inspection records to OFSM to ensure Hines is compliant Provide certification process guidance and ensure permits are current and displayed Perform limited preventative maintenance repair that can be only accomplished by certified contractor This contractor shall adhere to all regulatory program inspection requirements. These requirements shall include the Energy Policy Act of 2005, 40 CFR 280 under RCRA, VHA Directive GEMS 7700 and Illinois State Fire Marshall (ISFM). In addition, the inspections include adherence to air quality programs as identified by the Illinois Administrative Code Title 35, Part 731. SCOPE Contractor shall contact Hines VA Engineering, Contracting Officer Representative (COR) to request onsite inspections at least, one (1) week prior to the visit. The contractor is required to perform inspections and maintenance during normal work hours 7:00am 3:30pm Monday through Friday. Inspections will not occur on weekends or government holidays. Contractor shall review records to include Spill Prevention, Control, and Countermeasure (SPCC) plans, tank registrations and compliance reports, agency inspections, tank vendor operating manuals, layout drawings, and permits. Contractor shall review the tank information available through Office of the Illinois State Fire Marshal agency databases and shall review state and local UST/AST code requirements with respect to the referenced tanks at the VA. Inspection-On site Contractor shall conduct on-site inspection of all tanks in Attachment 2, with VA personnel to verify the current state and conditions of the UST/AST systems. The site inspection shall be conducted by a certified Level A and B UST/AST Tank System Inspector and Illinois certified tank installer. The inspection shall require both written and photo documentation if emergency or damage is discovered. The inspection shall include demonstration of the operation using real time monitoring systems used by VA personnel. This inspection shall include spill and overfill protection, corrosion protection, leak detection, secondary containment, spill preparedness kits for response, reporting of releases, and applicable compliance requirements. Inspection-On site Time Frame and Delivery Monthly Inspection: 3rd or 4th week of month Annual Inspection: Month of October-No time constraints Triennial Inspection: Month of October-No time constraints AST Inspection Note No monthly inspections needed on AST Only Fuel is tested once a year : Month of October-No time constraints Inspection Close out At the completion of the on-site inspection, the contractor shall conduct an Inspection review meeting with VA representatives to present findings. Meeting Agenda shall include identification of regulatory deficiencies discovered that could result in significant action by US EPA, IEPA, OISFM, state, local agencies or risk to patient health. The contractor shall review Hines VA tank program documentation/records of Inspected elements such as: tank registration forms, financial responsibility, submittals, tank testing, and tank inspections. Contractor to provide formalized report using OSFM Standards REPORTING REQUIREMENTS GEMS Documentation/Reports-Defined The Contractor shall be responsible to provide VA Engineering Service with a typed formal report of services performed. This formal Vendor Engineering Service Report shall include results, details and data for all services performed. Contractor shall provide a report presenting inspection findings and fix recommendations for each tank system. Items to be included & reported during inspections: Tank Conditions Notification (failure to notify) Corrosion protection Tank Corrosion protection Piping Condition on retractors, hoses, breakaways, vapor caps, rubber gaskets, and swivels (dispensing islands only) Condition of all gauges and meters Overfill/Spill Overfill prevention is in place and operational Spill prevention is in place and operational Tank and piping release detection Inspect piping/fitting conditions for failures, potential failures Detection methods and appropriate equipment or procedures are in place: alarms, interstitial piping, sump sensors Inspection, removal and disposal of debris in spill buckets. Secondary containment is present where required Required Documentation Prior to approval of invoices, contractor shall provide documents of: Tank and piping repairs performed by contractor Any notice of Temporary tank closure or Permanent tank decommissioning and removal Documentation on inspecting Operator training Class A, B, and C Time stamps of equipment downtime/uptime and hours on-site for service call Identification of equipment to be serviced Inventory ID number, manufacturer's name, device name, model number, serial number, and any other manufacturer's identification numbers Itemized description of service(s) performed Name of Veteran Administration employee who witnessed service described Name of Field Service Engineer (FSE) who performed services Contractor service number or contractor log number Pass or Fail per tank inspected OSFM Quarterly Equipment Inspection Checklist/Operations & Maintenance Guidelines for UST System Inspections per tank GENERAL REQUIREMENTS Contractor to furnish all labor, materials, and transportation necessary to include: All work under the provisions of this contract shall be performed by properly licensed and certified UST technicians directly employed by the contractor. UST Technicians shall be fully trained and experienced in the servicing of the systems and devices specified. Subject to COR approval. In addition to the conformance section of the specifications all work under the provisions of this contract shall be performed and certified as being in full compliance with all applicable laws, regulations and codes. At all times while performing work under the provisions of this contract the contractor s employees shall strictly observe the requirements of all applicable Occupational Safety and Health Administration, Environmental Protection Agency, Department of Veterans Affairs rules and the Illinois State Fire Marshal, regulations and policies. Existing UST alarms, piping and system components or devices found to be in a state of failure shall be reported to the COR for appropriate corrective action. Contractor shall troubleshoot and diagnosis as necessary to determine the cause of the problem identified. Contractor shall provide a cost proposal to make corrections or repairs to identify deficiencies for consideration by facility personnel. CONTRACTOR QUALIFICATIONS The contractor shall maintain an adequate inventory of parts, materials and supplies as necessary to provide for the timely maintenance, testing and repair of the specified UST/AST systems components and devices. Failure by the contractor to satisfactorily accomplish required inspections by the provisions of this contract in a timely manner because of a lack of parts/equipment availability shall be considered justification to terminate the contract in accordance with the Default Clause. Firms shall have been engaged in business of installing, repairing, testing, maintaining UST systems, and components verifying compliance with the Illinois State Fire Marshall and other regulatory offices for at least the past five (5) consecutive years. Bidders shall provide list of the names, addresses and telephone numbers of three (3) customer references with preference towards experience with the Federal or Illinois State governments. Contractors shall provide proof of Illinois Class A,B, and C UST certification in bid. Due to the dangers with Above and Underground Storage Tanks, there shall be no subcontracting opportunities for potential general contractors. Communications shall be from government to the self-performing contractor and vice versa only.

From Sources Sought posted on May 04, 2026

Notice history

1
  1. Sources Sought LATEST Posted May 04, 2026 View

Details

Solicitation number 36C25226Q0450
Notice ID 446ad7603f0045caa95aa7da22d8094e
Notice type Sources Sought
Product / Service (PSC) H335
NAICS 541620
Place of performance Hines, Illinois
Archive date Jul 06, 2026

Award Information

Awardees
0

Documents

1
View on SAM.gov

Contacts

primary
Lemke, Justin

Contract Specialist

Email

Phone

Agency

VETERANS AFFAIRS, DEPARTMENT OF
VETERANS AFFAIRS, DEPARTMENT OF
252-NETWORK CONTRACT OFFICE 12 (36C252)

Place of Performance

Edward Hines, Jr. VA Hospital
5000 South 5th Avenue
Hines, Illinois 60141-5000
USA

Dates

Posted May 04, 2026 3 months ago
Last Updated Aug 06, 2026 1 day ago
Due May 07, 2026 3 months ago