H312--Annual Fire Door Inspection POP: 07/31/2025 - 09/30/2025 36C26225Q1058
Summary
AI-generated · Aug 25, 2025Annual Fire & Smoke Door Inspection is required to meet VHA requirements and The Joint Commission LS.02.01.10, using NFPA 80, 101, and 105 standards. Inspect 130 doors in Buildings 1 & 11 interstitial spaces; 366 doors in Buildings 1 & 11 non-interstitial spaces; and 4 roll-up Fire & Smoke Doors in non-interstitial spaces. There is known asbestos located within the interstitial spaces of Building 1, which will affect access and safety planning.
Presolicitation information adds the exact door counts and confirms asbestos in interstitial spaces, informing bidders to plan for specialized safety procedures, access requirements for interstitial areas, and coordination with facility personnel to ensure compliance with the referenced NFPA standards and regulatory safety requirements.
The Department of Veterans Affairs, San Diego VA Healthcare System, located at 3350 La Jolla Village Drive, San Diego, CA 92161; has a requirement to conduct Fire & Smoke Door Inspection annually to meet VHA Requirements and adherence to The Joint Commission LS.02.01.10 to utilize the NFPA 80, 101, and 105 standards. There is known Asbestos located within the interstitial spaces of building 1. Below are the number of doors located throughout the hospital that will be required to be inspected: Inspect 130 Doors within Buildings 1 & 11 Interstitial spaces Inspect 366 Doors throughout Buildings 1 & 11, non-Interstitial spaces. Inspect 4 Roll-up Fire & Smoke Doors, non-Interstitial spaces.
From Presolicitation posted on Jun 23, 2025Requirement to conduct Fire & Smoke Door Inspection annually to meet VHA Requirements and adherence to The Joint Commission LS.02.01.10 to utilize the NFPA 80, 101, and 105 standards.
From Solicitation posted on Jun 25, 2025Presolicitation Notice Presolicitation Notice Page 3 of 3 Presolicitation Notice *=Required Field Presolicitation Notice Page 1 of 3 The Department of Veterans Affairs, San Diego VA Healthcare System, located at 3350 La Jolla Village Drive, San Diego, CA 92161; has a requirement to conduct Fire & Smoke Door Inspection annually to meet VHA Requirements and adherence to The Joint Commission LS.02.01.10 to utilize the NFPA 80, 101, and 105 standards. There is known Asbestos located within the interstitial spaces of building 1. Below are the number of doors located throughout the hospital that will be required to be inspected: Inspect 130 Doors within Buildings 1 & 11 Interstitial spaces Inspect 366 Doors throughout Buildings 1 & 11, non-Interstitial spaces. Inspect 4 Roll-up Fire & Smoke Doors, non-Interstitial spaces.
From Solicitation posted on Jul 07, 2025Notice history
3-
Presolicitation Posted Jun 23, 2025
-
Solicitation Posted Jun 25, 2025View changes (3)
- Description: Description was updated
- Notice Type: Presolicitation → Solicitation
- Set-Aside: Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14) → None