H159--VANIHCS 3 Year Electrical Testing Marion and Fort Wayne 36C25026Q0067

Solicitation 36C25026Q0067 Copied Notice ID 1762a6968e5541c59f3d0bfdff2e856e Copied VETERANS AFFAIRS, DEPARTMENT OF — 250-NETWORK CONTRACT OFFICE 10 (36C250)
SAM.gov
Posted
Dec 17, 2025
Deadline
No deadline
Set-aside
SDVOSBC
NAICS
811210
PSC
H159

Summary

AI-generated · Oct 21, 2025

Perform cleaning, testing, adjusting, calibration, inspection, and retorque of electrical distribution equipment, including power transformers, switchgear, motor control centers, distribution centers, panel boards, air circuit breakers, vacuum circuit breakers, and loop switches listed in Attachment I SOW Attachments. Over-current testing is limited to over-current relays for each 15 kV and 5 kV circuit breaker.

Megger test voltages must not exceed IEEE standards, and no high-potential voltage may be applied to feeder wires. All equipment must be isolated from panels and feeders during testing to ensure accurate data readings, with no variance allowed. The contractor must reinstall equipment to its original condition, verify voltage, phasing, and rotation. Any damage due to contractor neglect is the contractor’s financial responsibility, and repairs outside this scope will incur additional charges and require prior approval from the COR and Contracting Officer before work begins.

Clean, test, adjust, calibrate, inspect and retorque all the below mentioned electrical distribution apparatus. This shall include, but not be limited to, power transformers, switchgear, motor control centers, distribution centers, panel boards, air circuit breaker, vacuum circuit breakers, and loop switches listed in Attachment I SOW Attachments. Over-current testing apparatus shall be limited to over-current relays for each 15 KV and 5 KV circuit breaker. Megger voltage shall not exceed IEEE standards. No high pot voltage to be applied to feeder wires. All equipment will be isolated from panel and feeders during testing for proper data reading. No variance. Contractor is responsible to reinstall equipment to original condition, verifying voltage, phasing and rotation. Any damage to equipment due to contractor neglect is the contractor s financial responsibility. Repairs outside this SOW will be at an additional charge to the VA and require prior approval from the COR and Contracting Officer before repairs are started.

From Presolicitation posted on Oct 20, 2025

N/A

From Solicitation posted on Oct 23, 2025

Post RFI responses, site visit sign in sheet and extend date/time quotes are due.

From Solicitation posted on Nov 07, 2025

The purpose of this amendment is to provide clarification to the set-aside requirement. This requirement is 100% Set-Aside for SDVOSB. This amendment also extends the quote due date from November 17, 2025, to November 21, 2025. All other terms and conditions remain unchanged.

From Solicitation posted on Nov 13, 2025

The purpose of this amendment is to provide additional RFI's and the VA's responses. This amendment also changes the response due date from November 21, 2025, to January 15, 2026.

From Solicitation posted on Nov 17, 2025

The purpose of this amendment is to changes the response due date from January 15, 2026, to December 5, 2025. This amendment also provides clarification to the period of performance stated on page 13 of the original solicitation. All other terms and conditions remain unchanged.

From Solicitation posted on Nov 19, 2025

Notice history

7
  1. Presolicitation Posted Oct 20, 2025 View
  2. Solicitation Posted Oct 23, 2025
    • Description: Description was updated
    • Notice Type: PresolicitationSolicitation
    • Set-Aside: Service-Disabled Veteran-Owned Small Business Set AsideNone
  3. Solicitation Posted Nov 07, 2025
    • Description: Description was updated
    • Response Deadline: Nov 14, 2025Nov 17, 2025
    • Set-Aside: NoneService-Disabled Veteran-Owned Small Business Set Aside
  4. Solicitation Posted Nov 13, 2025
    • Description: Description was updated
    • Response Deadline: Nov 17, 2025Nov 21, 2025
  5. Solicitation Posted Nov 17, 2025
    • Description: Description was updated
    • Response Deadline: Nov 21, 2025Jan 15, 2026
  6. Solicitation Posted Nov 19, 2025
    • Description: Description was updated
    • Response Deadline: Jan 15, 2026Dec 05, 2025
  7. Award Notice LATEST Posted Dec 17, 2025

Details

Solicitation number 36C25026Q0067
Notice ID 1762a6968e5541c59f3d0bfdff2e856e
Award number 36C25026P0229
Notice type Award Notice
Product / Service (PSC) H159
NAICS 811210
Archive date Feb 15, 2026

Award Information

Awardee
1
Total Awarded
$378,520.00
Award Date
Dec 17, 2025

Awardees

Company Name UEI CAGE Code Location
ANDY RAMOS ELECTRIC LLC DKAHJWDMD2F7 58GU1 HOLYOKE

Documents

1
View on SAM.gov

Contacts

primary
Tiffany Rausch

Contract Specialist

Email

Agency

VETERANS AFFAIRS, DEPARTMENT OF
VETERANS AFFAIRS, DEPARTMENT OF
250-NETWORK CONTRACT OFFICE 10 (36C250)

Place of Performance

Dates

Posted Dec 17, 2025 7 months ago
Last Updated Aug 06, 2026 1 day ago
Awarded Dec 17, 2025 7 months ago