Contacts, documents and full notice history are available with a subscription.
Award Notice SDVOSBC 5 notices 1 document

H146--Critical SPS Water Testing Milwaukee VAMC and Green Bay CBOC 695C60326 36C25226Q0092

Solicitation 36C25226Q0092 Copied Notice ID fb6c877778344ef394e845abe34ad7bf Copied VETERANS AFFAIRS, DEPARTMENT OF — 252-NETWORK CONTRACT OFFICE 12 (36C252)
SAM.gov
Posted
Apr 02, 2026
Deadline
No deadline
Set-aside
SDVOSBC
NAICS
541380
PSC
H146

Summary

AI-generated · Jan 21, 2026

Critical water testing for Sterile Processing Service at the Clement J. Zablocki VA Medical Center in Milwaukee and the Milo C. Huempfner Health Care Center in Green Bay, WI, to ANSI/AAMI ST108 standards. The work involves testing the water used in SPS processes at both facilities to ensure it meets the required quality and safety specifications.

The notice has progressed from presolicitation to solicitation, indicating the procurement is moving toward award, but no contract has been posted yet (award amounts shown as $0.00). The description does not specify brand-name requirements, site visits, or additional certifications.

SPS Critical Water Testing to ANSI/AAMI ST108 Standards. The Clement J. Zablocki VA Medical Center (ZVAMC) in Milwaukee, WI Sterile Processing Service (SPS) and Milo C. Huempfner Health Care Center (HCC) (GB HCC) in Green Bay, WI

From Presolicitation posted on Jan 20, 2026

SPS Critical Water Testing to ANSI/AAMI ST108 Standards. The Clement J. Zablocki VA Medical Center (ZVAMC) in Milwaukee, WI Sterile Processing Service (SPS) and Milo C. Huempfner Health Care Center (HCC) (GB HCC) in Green Bay, WI

From Solicitation posted on Jan 20, 2026

SPS Critical Water Testing to ANSI/AAMI ST108 Standards. The Clement J. Zablocki VA Medical Center (ZVAMC) in Milwaukee, WI Sterile Processing Service (SPS) and Milo C. Huempfner Health Care Center (HCC) (GB HCC) in Green Bay, WI

From Solicitation posted on Jan 29, 2026

Who will provide the bottles for specimen testing? The vendor will supply all bottles, tubes, cold packs, packaging and any other material supplies needed to perform and ship the specimens to maintain sample viability. Regarding the Perry Johnson Laboratory Accreditation (PJLA)Testing Accreditation and International Organization for Standardization (ISO) and International Electrotechnical Commission (IEC) 17025:2017 certifications, We have the A2LA Laboratory Certification, Elite Laboratory and the ASSE International Certification. Our questions is: Do we have to have the PJLA or is the Certifications that we have for testing sufficient? We will let the verbiage in the original documents stand. PJLA certification is required. Would the VA like us to incorporate an SOP for the SPS?. This would not be a need as part of the contract. 4. To make sure hold times are not exceeded in the event of shipping samples, will sampling in the afternoon be acceptable? Sampling in the afternoon is acceptable provided it does not delay delivery to the lab or interfere with maintaining appropriate chain of custody. 5. Can you please confirm the parameters needed to be tested monthly for the first point of generation critical water chemistry panel with micro. ST108 outlines all of the testing parameters. If the vendor is not aware of these testing parameters, the vendor likely lacks the knowledge or experience to adequately perform critical water testing. Please see attached document for the ST108 standard. 6. are field tests acceptable for pH, Alkalinity, conductivity, and hardness or will these need to be done by a Lab? Final results need to be conducted through lab analysis. 7. Does the Lab have to have PJLA certification or is another ANSI recognized auditing body such as ANAB acceptable for ISO certification? PJLA certification is required. 8. The solicitation states results must be password protected, does this apply only to the database where results are stored, or do emails need to be encrypted? Emails do not need to be encrypted. The web-based reporting structure should be password protected. 9. Clarification on how many of the tests are being run prior to the UV? UV treatment is continual in our critical water loops, with the exception of the cart washer loop at the Green Bay facility, where there is no UV treatment.

From Solicitation posted on Feb 04, 2026

Notice history

5
  1. Presolicitation Posted Jan 20, 2026 View
  2. Solicitation Posted Jan 20, 2026
    • Notice Type: PresolicitationSolicitation
    • Response Deadline: Feb 02, 2026Dec 05, 2025
    • Set-Aside: Service-Disabled Veteran-Owned Small Business Set AsideNone
  3. Solicitation Posted Jan 29, 2026
    • Response Deadline: Dec 05, 2025Feb 09, 2026
  4. Solicitation Posted Feb 04, 2026
    • Description: Description was updated
  5. Award Notice LATEST Posted Apr 02, 2026

Details

Solicitation number 36C25226Q0092
Notice ID fb6c877778344ef394e845abe34ad7bf
Award number 36C25226P0231
Notice type Award Notice
Product / Service (PSC) H146
NAICS 541380
Archive date May 02, 2026

Award Information

Awardee
1
Total Awarded
$474,246.28
Award Date
Apr 01, 2026

Awardees

Company Name UEI CAGE Code Location
I-2-I Solutions, Inc. KBLVEEKP3DN5 9MBK2 RICHMOND

Documents

1
View on SAM.gov

Contacts

primary
Debbie Bruening

Contract Specialist

Email

Phone

Agency

VETERANS AFFAIRS, DEPARTMENT OF
VETERANS AFFAIRS, DEPARTMENT OF
252-NETWORK CONTRACT OFFICE 12 (36C252)

Place of Performance

Dates

Posted Apr 02, 2026 4 months ago
Last Updated Aug 06, 2026 2 days ago
Awarded Apr 01, 2026 4 months ago