Contacts, documents and full notice history are available with a subscription.
Sources Sought NONE Expired 1 notice

Gas Chromatograph with Dual Electron Capture Detector (GS-Dual ECD) PANHCA-25-P-0000-025637

Solicitation PANHCA-25-P-0000-025637 Copied Notice ID 73114fdc98b142efbb8939f5409d7506 Copied DEPT OF DEFENSE — W40M MRCO EUROPE
SAM.gov
Posted
Jul 23, 2025
Deadline
Jul 29, 2025
Set-aside
NONE
NAICS
339112
PSC
6630

Summary

AI-generated · Aug 24, 2025

Market research to identify parties capable of supplying a Gas Chromatograph with Dual Electron Capture Detectors (GC with two ECDs) and two liquid autosamplers, to screen drinking water and food samples for a wide array of organic pollutants. The system must include an operation workstation and data acquisition/processing software compatible with Windows 11; two split/splitless injection ports; two EPCs with independent detection capability; 230V/50 Hz operation; two autosamplers with at least a 150-sample tray and cooling to -6°C; and the ability to perform simultaneous dual-column injections onto two inlets. It should feature an integrated two-column compartment with quick-connect fittings, include all necessary EPA method consumables for EPA 505, 504.1, 515.4, and 553.2 (e.g., splitless liners, dissimilar pesticide columns, ferrules, seals), and come with a minimum one-year warranty, operation/troubleshooting manuals, and installation by a qualified service representative with system verification. This is market research, not a solicitation, and information provided will help determine procurement approach.

To participate, provide: name and address of your firm; primary point of contact (name, phone, email); company website; Unique Entity Identifier (UEI); Commercial and Government Entity (CAGE) code; and a capability statement.

THIS IS A SOURCES SOUGHT/REQUEST FOR INFORMATION ONLY. This is not a Solicitation Announcement, nor is it a Request for Proposal. This request does not obligate the Government in any contract award. The USAHCA Medical Readiness Contracting Office Europe-USAHCA-MRCO-EUR is issuing the sources sought synopsis as a means of conducting market research to identify parties having an interest in and the resources to support the requirement for Gas Chromatograph with Dual Electron Capture Detector. The result of this market research will contribute to determining the method of procurement. The applicable North American Industry Classification System (NAICS) code assigned to this procurement is 339112 (Surgical and Medical Instrument Manufacturing) with business size standard 1,000 Employees. PSC code is 6630 Chemical Analysis Instruments. The anticipated delivery 45 days after contract award. The delivery address: Regional Landstuhl Medical Center Landstuhl, Germany S ALIENT CHARACTERISTICS Brand Name or Equal Gas Chromatograph with dual Electron Capture Detector (GC-?ECD) and dual liquid autosamplers with the ability to screen drinking water and food samples for a wide array of prominent and emergent organic pollutants simultaneously. o Operation Workstation must be included with the equipment. o Data acquisition and processing software to control instrument and process data must be included. o System must run all software on Windows 11. o System must have two split/split less injection ports. o System must have two Electron Capture Detectors with EPCs. o The instrument must have capability for simultaneous and independent detection of each ECD. o Equipment must be able to operate on 230V/50 Hz. Two liquid autosamplers must be included with the equipment, including a tray for samples. o Auto-sampler tray with capacity of at least 150 samples and ability to cool samples ?6C. o Instrument must include two autosamplers with the capability for simultaneous dual column injection onto two inlets. The GC system must have an integrated compartment with capability for at least 2 columns with quick-connect fittings for facile switching between methods. The instrument must have capability for simultaneous and independent detection of each ECD. The system should come equipped with all necessary consumables to run methods EPA 505, 504.1, 515.4 and 553.2 (Split less liners, Dissimilar Pesticide columns, ferrules, seals, etc.) The system must come with a minimum of a one-year warranty. The system must come with operation and troubleshooting manuals. Instrument must be installed by a qualified service representative and properly verified for use. If you are interested in participating in this requirement and/or your organization has the potential capacity to perform these services, please submit the following to the Point of Contacts (POC) information listed below: 1. Name and Address of your Firm 2. Point of Contact (name/phone/email) 3. Company website 4. Unique Entity identifier (UEI) number 5. Commercial and Government Entity (CAGE) code 6. Capability statement -

From Sources Sought posted on Jul 23, 2025

Notice history

1
  1. Sources Sought LATEST Posted Jul 23, 2025 View

Details

Solicitation number PANHCA-25-P-0000-025637
Notice ID 73114fdc98b142efbb8939f5409d7506
Notice type Sources Sought
Product / Service (PSC) 6630
NAICS 339112
Set-aside No Set aside used
Place of performance Rhineland-Palatinate
Archive date Aug 13, 2025

Award Information

Not yet awarded

Documents

No files available

View on SAM.gov

Contacts

primary
Bouaphet Phanvongsa

Email

Phone

secondary
Michael Hughes

Email

Agency

DEPT OF DEFENSE
DEPT OF THE ARMY
US ARMY MEDICAL COMMAND
W40M MRCO EUROPE

Place of Performance

Rhineland-Palatinate 09180
DEU

Dates

Posted Jul 23, 2025 1 year ago
Last Updated Aug 06, 2026 1 day ago
Due Jul 29, 2025 1 year ago