Gas Chromatograph with a Flame Ionization Detector and Pulsed Discharge Helium Ionization Detector (GC-FID/PDHID) 1333ND25QNB640356
Summary
AI-generated · Aug 25, 2025Procure a gas chromatograph equipped with a flame ionization detector and a pulsed discharge helium ionization detector to support development of NIST Traceable Reference Materials, Reference Materials, and Standard Reference Materials for high-quality, traceable gas measurements used in standards, international comparisons, and certified gas certifications. The instrument should have two channels that can operate simultaneously or in parallel, with a 5 mL sample loop (acceptance testing at NIST with loop ≤1 mL), and routinely use a 12 x 1/8 Hayesep D 80/100 packed column. Include a gas sampling valve to select between samples and a stop-flow valve to equilibrate pressure, chromatography data system software with Agilent GC control, and a control computer if external processing is required. On-site installation and training in Gaithersburg, MD are required, with acceptance testing after install at NIST and a training class for three people.
Amendments add readability to the requirements and provide government responses to industry questions, including clarifications on valve configuration (two channels that can operate in parallel), loop volume (supporting up to 5 mL, tested at ≤1 mL), column type (packed Hayesep D recommended for initial use), the option of capillary columns, data-system/controls, and on-site installation details, and extend the bid due date.
The Gas Sensing Metrology Group (GSMG) of the Chemical Sciences Division is responsible for developing, critically evaluating, and applying techniques for the identification and measurement of gaseous species. The group applies these techniques with the certification of gas standards in support of industries responding to U.S. and state regulations and fairness in trade issues. The primary concern is to provide the infrastructure for high-quality, traceable gas measurements, allowing better decision-making by industry, regulators, government officials, research scientists, and the public. Measurement services are provided through the development of reference materials including NIST Traceable Reference Materials (NTRMs), Reference Materials (RMs), Standard Reference Materials (SRMs). The GSMG needs to purchase a gas chromatograph with a flame ionization detector and pulsed discharge helium ionization detector in order to support the development of SRMs, NTRMs as well as for standards used for international comparisons and other certified compress gases.
From Combined Synopsis/Solicitation posted on Jul 29, 2025Amendment 0001 is being issued to provide a readable verison of the Requirement/Specifications ____________________________________________________________________________ The Gas Sensing Metrology Group (GSMG) of the Chemical Sciences Division is responsible for developing, critically evaluating, and applying techniques for the identification and measurement of gaseous species. The group applies these techniques with the certification of gas standards in support of industries responding to U.S. and state regulations and fairness in trade issues. The primary concern is to provide the infrastructure for high-quality, traceable gas measurements, allowing better decision-making by industry, regulators, government officials, research scientists, and the public. Measurement services are provided through the development of reference materials including NIST Traceable Reference Materials (NTRMs), Reference Materials (RMs), Standard Reference Materials (SRMs). The GSMG needs to purchase a gas chromatograph with a flame ionization detector and pulsed discharge helium ionization detector in order to support the development of SRMs, NTRMs as well as for standards used for international comparisons and other certified compress gases.
From Combined Synopsis/Solicitation posted on Aug 11, 2025The Gas Sensing Metrology Group (GSMG) of the Chemical Sciences Division is responsible for developing, critically evaluating, and applying techniques for the identification and measurement of gaseous species. The group applies these techniques with the certification of gas standards in support of industries responding to U.S. and state regulations and fairness in trade issues. The primary concern is to provide the infrastructure for high-quality, traceable gas measurements, allowing better decision-making by industry, regulators, government officials, research scientists, and the public. Measurement services are provided through the development of reference materials including NIST Traceable Reference Materials (NTRMs), Reference Materials (RMs), Standard Reference Materials (SRMs). The GSMG needs to purchase a gas chromatograph with a flame ionization detector and pulsed discharge helium ionization detector in order to support the development of SRMs, NTRMs as well as for standards used for international comparisons and other certified compress gases. _____________________________________________________________________________________________________ Amendment 0001 is being issued to provide a readable verison of the Requirement/Specifications. Amendment 0002 is being issued to provide government rssponse to additional questions submited from industry and extend the due date for offers. Do you want separate Valco gas sampling valves for the FID and PDHID channels? Or do you want one dual gas sampling valve that will simultaneously inject on both? Government Response: We would like two channels that can operate simultaneously OR in parallel What injection volume do you want, given your column and detection requirements? Government Response: The instrument needs to have sufficient space to allow for a 5 ml sample loop, but acceptance testing at NIST will be performed using a sample loop at or below 1 ml. Do you want to use capillary columns or packed columns? If so, what columns do you want to use, at least initially? Government Response: Routine analyses will be performed using a 12 x 1/8 Hayesep D 80/100 packed column If you want to use capillary columns, do you want us to include at least one split/splitless inlet on the FID channel? Government Response:Not critical We assume you want us to include chromatography data system software with Agilent GC control. What about a control computer? Government Response: If an external computer is required to process the data, please provide one We assume you want on-site installation and training in Gaithersburg, Maryland? Government Response: Correct Do you want any Factory Acceptance Testing (FAT)? Government Response: Acceptance testing will be performed after install at NIST Do you want a GC class at our facility? Government Response: We would like a class/training for 3 people Do you want any automated stream selection, or a stop flow valve to equilibrate sample injection pressure? Government Response: We need both a gas sampling valve (to select between samples) and a stop flow valve to allow pressure equilibration within the sample loop.
From Combined Synopsis/Solicitation posted on Aug 12, 2025The Gas Sensing Metrology Group (GSMG) of the Chemical Sciences Division is responsible for developing, critically evaluating, and applying techniques for the identification and measurement of gaseous species. The group applies these techniques with the certification of gas standards in support of industries responding to U.S. and state regulations and fairness in trade issues. The primary concern is to provide the infrastructure for high-quality, traceable gas measurements, allowing better decision-making by industry, regulators, government officials, research scientists, and the public. Measurement services are provided through the development of reference materials including NIST Traceable Reference Materials (NTRMs), Reference Materials (RMs), Standard Reference Materials (SRMs). The GSMG needs to purchase a gas chromatograph with a flame ionization detector and pulsed discharge helium ionization detector in order to support the development of SRMs, NTRMs as well as for standards used for international comparisons and other certified compress gases. _____________________________________________________________________________________________________ Amendment 0001 is being issued to provide a readable verison of the Requirement/Specifications. Amendment 0002 is being issued to provide government rssponse to additional questions submited from industry and extend the due date for offers. Do you want separate Valco gas sampling valves for the FID and PDHID channels? Or do you want one dual gas sampling valve that will simultaneously inject on both? Government Response: We would like two channels that can operate simultaneously OR in parallel What injection volume do you want, given your column and detection requirements? Government Response: The instrument needs to have sufficient space to allow for a 5 ml sample loop, but acceptance testing at NIST will be performed using a sample loop at or below 1 ml. Do you want to use capillary columns or packed columns? If so, what columns do you want to use, at least initially? Government Response: Routine analyses will be performed using a 12 x 1/8 Hayesep D 80/100 packed column If you want to use capillary columns, do you want us to include at least one split/splitless inlet on the FID channel? Government Response:Not critical We assume you want us to include chromatography data system software with Agilent GC control. What about a control computer? Government Response: If an external computer is required to process the data, please provide one We assume you want on-site installation and training in Gaithersburg, Maryland? Government Response: Correct Do you want any Factory Acceptance Testing (FAT)? Government Response: Acceptance testing will be performed after install at NIST Do you want a GC class at our facility? Government Response: We would like a class/training for 3 people Do you want any automated stream selection, or a stop flow valve to equilibrate sample injection pressure? Government Response: We need both a gas sampling valve (to select between samples) and a stop flow valve to allow pressure equilibration within the sample loop.
From Combined Synopsis/Solicitation posted on Aug 13, 2025Notice history
4-
Combined Synopsis/Solicitation Posted Jul 29, 2025
-
Combined Synopsis/Solicitation Posted Aug 11, 2025View changes (1)
- Description: Description was updated
-
Combined Synopsis/Solicitation Posted Aug 12, 2025View changes (2)
- Description: Description was updated
- Response Deadline: Aug 13, 2025 → Aug 16, 2025
-
Combined Synopsis/Solicitation LATEST Posted Aug 13, 2025No changes from previous notice