AI-generated · May 27, 2026Design-Build project to remove the existing built-up roof from Building 10571, a historic, single-story facility, down to the structural decking. The building includes a main open area about 200 ft by 229 ft with a barrel roof of approximately 50,000 SF and three low-slope lean-to sections (North 36 ft by 268 ft; South 36 ft by 229 ft; West 36 ft by 180 ft). Replace the barrel center section with a 3-ply SBS-Modified BUR roof assembly containing a granular cap sheet, and replace the three lean-to sections with new 90-mil EPDM roof assemblies, both fully adhered. Replace all associated components, including roof drains, flashings (roof and vent), cover board, insulation, vapor barrier, cant strips, metal copings, and trim.
Site visit is scheduled for 8 June at 1:00 PM local time.
Site Visit is scheduled for 8 June at 1:00PM (Local Time). Building 10571 is a one-story, 68986 square feet (SF) building framed from steel and cast concrete (beams and columns with CMU infill). The building was originally constructed in the early 1940s and is a historic property. The main open space is 200-ft by 229 ft with a high barrel roof section that?s approximately 50,000 SF. Additionally, there are three (3) low slope roof lean-to sections. The North lean-to section is approximately 36-ft by 268-ft, with the South lean-to section at approximately 36-ft by 229-ft. The West lean-to section is approximately 36-ft by 180-ft. This Design-Build project will remove the existing built-up roof (BUR) from both barrel center section and the three (3) lower roof lean-to sections down to the existing structural decking. New 3-ply SBS-Modified BUR roof assembly with granular cap sheet on the barrel roof section shall be installed and the three (3) lower roof lean-to sections shall be replaced with new 90-mil Ethylene Propylene Diene Monomer (EPDM) roof assemblies. All roofing assemblies shall be fully adhered. Replace existing roof drains, flashings, vent pipe flashing, cover board, insulation, vapor barrier, cant strips, metal copings and trim with new.
From Combined Synopsis/Solicitation posted on May 26, 2026Site Visit is scheduled for 8 June at 1:00PM (Local Time). Building 10571 is a one-story, 68986 square feet (SF) building framed from steel and cast concrete (beams and columns with CMU infill). The building was originally constructed in the early 1940s and is a historic property. The main open space is 200-ft by 229 ft with a high barrel roof section that?s approximately 50,000 SF. Additionally, there are three (3) low slope roof lean-to sections. The North lean-to section is approximately 36-ft by 268-ft, with the South lean-to section at approximately 36-ft by 229-ft. The West lean-to section is approximately 36-ft by 180-ft. This Design-Build project will remove the existing built-up roof (BUR) from both barrel center section and the three (3) lower roof lean-to sections down to the existing structural decking. New 3-ply SBS-Modified BUR roof assembly with granular cap sheet on the barrel roof section shall be installed and the three (3) lower roof lean-to sections shall be replaced with new 90-mil Ethylene Propylene Diene Monomer (EPDM) roof assemblies. All roofing assemblies shall be fully adhered. Replace existing roof drains, flashings, vent pipe flashing, cover board, insulation, vapor barrier, cant strips, metal copings and trim with new.
From Combined Synopsis/Solicitation posted on Jun 23, 2026Notice history
2-
Combined Synopsis/Solicitation Posted May 26, 2026
-
Combined Synopsis/Solicitation LATEST Posted Jun 23, 2026View changes (1)
- Response Deadline: Jun 26, 2026 → Jul 02, 2026