Fort Peck Excitation System Upgrade W9128F27RA001
Summary
AI-generated · Feb 24, 2026Fort Peck Dam’s excitation system modernization involves assessing options to upgrade the two powerhouses (five generating units) on the Missouri River near Glasgow, MT. The aging excitation systems show reliability and supportability concerns due to obsolete front-end components, legacy upgrades, and deteriorating controls. For Powerhouse 1 (Units 1–3), a targeted modernization may replace failing front-end components while reusing the existing digitals regulator hardware and cubicles, with modifications as needed.
For Powerhouse 2 (Units 4–5), a full replacement may be pursued, potentially removing existing equipment and installing new digital static excitation systems. This Sources Sought is for market research to assess industry capability, interest, and potential acquisition strategies, and it does not constitute a solicitation.
Background USACE is seeking information from interested and qualified contractors regarding potential modernization of excitation systems at Fort Peck Dam, a remote hydroelectric facility located on the Missouri River near Glasgow, Montana. The facility consists of two powerhouses with a total of five generating units. Existing excitation systems present reliability and supportability concerns due to aging equipment, partial legacy upgrades, and obsolescence of key control components. Powerhouse 1 Units 1 3 Existing digital excitation regulator hardware remains serviceable. Front-end excitation controls, field breakers, and operator interface components are obsolete and/or experiencing reliability issues. The Government is evaluating a targeted excitation system modernization approach, which may include replacement of failing or obsolete front-end components while reusing existing regulator hardware and cubicles, with modifications as required. Powerhouse 2 Units 4 5 Existing excitation systems include legacy components operating beyond their recommended design life. The Government is evaluating a full excitation system replacement for these units, which may include removal of existing equipment and installation of new digital static excitation systems. This Sources Sought notice is issued solely for market research purposes to assess industry capability, interest, and potential acquisition strategies. It does not constitute a solicitation.
From Sources Sought posted on Feb 23, 2026Notice history
1-
Sources Sought LATEST Posted Feb 23, 2026
Details
Award Information
Not yet awarded
Contacts
Agency
Place of Performance
USA