Contacts, documents and full notice history are available with a subscription.
Combined Synopsis/Solicitation NONE Expired 1 notice 3 documents

Fire Suppression Monitoring and Pump Inspections 75H70926BAO-012-RFQ

Solicitation 75H70926BAO-012-RFQ Copied Notice ID 8abadf6b748540c59270c89ffcfe8845 Copied HEALTH AND HUMAN SERVICES, DEPARTMENT OF — BILLINGS AREA INDIAN HEALTH SVC
SAM.gov
Posted
Jan 16, 2026
Deadline
Jan 23, 2026
Set-aside
NONE
NAICS
922160
PSC
H312

Summary

AI-generated · Jan 17, 2026

Perform annual inspections of all fire sprinkler and fire alarm systems and jockey pumps at the Crow Service Unit, covering Crow/Northern Cheyenne Hospital, Pryor Health Clinic, and Lodge Grass Health Clinic. The work includes one annual inspection and fire pump test (including antifreeze solution and valves), three quarterly inspections of supervisory switches and alarms at each location, and one complete annual fire alarm system inspection per NFPA 72 with testing of initiating devices, notification devices, fire alarm control panel functions, and related auxiliary functions, with written documentation provided to the owner. Ancillary devices to test include remote annunciator, kitchen hood (Ansul units), and digital dialer.

Also required are annual fire extinguisher inspections and certification, sixty-seven semi-annual inspections and certifications of the kitchen hood fire suppression system, one hands-on live fire training for 354 individuals, fire sprinkler inspections and sprinkler pump tests for Pryor Clinic, Lodge Grass Clinic, and Crow/Northern Cheyenne Hospital, annual backflow testing at each location, and fire alarm monitoring services for three locations.

PROJECT TITLE: CSU Annual Fire Sprinkler, Fire Alarm, Monitoring and Pump Inspection BACKGROUND/PURPOSE: The contractor shall perform annual inspection on all fire sprinkler, fire alarm systems and jockey pumps at the Crow Service Unit. Sites will include Crow/Northern Cheyenne Hospital, Pryor Health Clinic and Lodge Grass Health Clinic. SCOPE: Inspection for the Automatic Fire Protection System at the Crow Hospital, Pryor Health Clinic and Lodge Grass Health Clinic. The survey will include: One Annual Inspection-Survey and Fire Pump Test to include testing the antifreeze solution and appropriate valves. Three (3) Quarterly Inspection Testing the Supervisory Switches and Alarms at each location. One complete Annual inspection of the Fire Alarm System as outlined in NFPA-72. Testing shall include fire alarm initiating devices, notification devises, fire alarm control panel functions, and any auxiliary functions that may be connected to the FACP Written documentation of the testing. Documentation shall be provided to owner. Ancillary Devices to be tested: Remote Annunciator, Kitchen Hood (Ansul Units), Digital Dialer (check out). Annual Fire Extinguisher Inspections and certification, sixty-seven (67) Semi-Annual Inspection and Certification of Kitchen Hood Fire Suppression System (1) Hand on live fire training for 354 individuals. Fire Sprinkler Inspection and Fire Sprinkler Pump Test for Pryor Clinic, Lodge Grass Clinic and Crow Northern Cheyenne Hospital. Annual back flow testing for each location (3) Fire Alarm Monitoring Services for 3 locations

From Combined Synopsis/Solicitation posted on Jan 16, 2026

Notice history

1
  1. Combined Synopsis/Solicitation LATEST Posted Jan 16, 2026

Details

Solicitation number 75H70926BAO-012-RFQ
Notice ID 8abadf6b748540c59270c89ffcfe8845
Notice type Combined Synopsis/Solicitation
Product / Service (PSC) H312
NAICS 922160
Set-aside No Set aside used
Place of performance Crow Agency, Montana
Archive date Feb 07, 2026

Award Information

Not yet awarded

Contacts

primary
KATRINA EAGLEFEATHERS

Email

Phone

Agency

HEALTH AND HUMAN SERVICES, DEPARTMENT OF
INDIAN HEALTH SERVICE
BILLINGS AREA INDIAN HEALTH SVC

Place of Performance

Crow Agency, Montana 59022
USA

Dates

Posted Jan 16, 2026 6 months ago
Last Updated Aug 06, 2026 2 days ago