Fire Alarm and Suppression System Maintenance FA568226QA001

Solicitation FA568226QA001 Copied Notice ID 467a6203c46b4623a238e358b08a4bd8 Copied DEPT OF DEFENSE — FA5682 31 CONS (UNIT 6102)
SAM.gov
Posted
Mar 25, 2026
Deadline
Apr 01, 2026
Set-aside
NONE
NAICS
N/A
PSC
N/A

Summary

AI-generated · Mar 26, 2026

Provide all personnel, equipment, tools, materials, supervision, and other non-personnel services necessary to perform comprehensive inspection, testing, and maintenance (ITM) of the existing fire alarm and water-based suppression systems at the VM Hangar and SOF facilities. The system is an Olympia Electronics analogue addressable BSR-1004 panel with four loops, with all suppression equipment downstream of the Main Control Valve. Tasks include semi-annual 100% functional and visual inspections of all components, testing every detector and notification appliance, cleaning addressable smoke detectors with 49% or higher analog level (with pre- and post-cleaning status reports from the fire alarm control panel), preventive maintenance, and on-call emergency repairs with onsite response within four hours; deficiencies must be corrected, with major issues requiring a written repair quote within five business days. Deliverables include an ITM schedule within 10 days of award, ITM reports within two working days after each inspection, a Certificate of Compliance annually and after the first semi-annual inspection, an emergency/extraordinary service report within two working days after repairs, and a weekly service submittal.

Contractor qualifications include a minimum of five years of continuous experience in inspecting, testing, maintaining, and repairing analogue addressable fire alarm systems; certified technicians; designated key personnel; language proficiency in the local language and English for interactions with the COR; appropriate licenses and insurance; and demonstrated emergency response capability to meet the four-hour on-site requirement. The contractor must ensure all work and replacements meet OEM specifications and comply with EN 54-2 and EN 54-4, CE marking and CPR requirements, and verify site conditions prior to starting. The work covers the fire alarm system and downstream water-based suppression equipment, including associated components such as tamper and pressure switches, flow switches, pumps, reservoirs, liners, bladders, and air compressors.

1.0 General Information 1.1 Description of Services & Introduction This Performance Work Statement (PWS) requires a contractor to provide all personnel, equipment, tools, materials, supervision, and other non-personnel services necessary to perform comprehensive inspection, testing, and maintenance (ITM) for the existing fire alarm and suppression systems installed at the VM Hangar and SOF facilities, as defined in this PWS. The contractor shall perform all services to the standards specified in this contract. 1.2 Background The facilities are equipped with an Olympia Electronics analogue addressable fire alarm system and associated water-based suppression systems. Proper maintenance and inspection are critical to ensure the safety of all personnel and the protection of government property. 1.3 Objectives The primary objective of this contract is to ensure the fire alarm and suppression systems are maintained in a constant state of readiness and full operational capability, compliant with all applicable standards and manufacturer requirements. 1.4 Scope The contractor shall provide all necessary management, supervision, labor, materials, tools, and equipment to perform comprehensive ITM, smoke detector cleaning, repair services, and technical assistance for the fire alarm and water-based suppression systems. This scope covers the Olympia Electronics BSR-1004 Analogue Addressable Fire Alarm Panel, all connected peripheral devices, and all water-based suppression systems and associated equipment as detailed in Section 2.0. 2.0 Equipment to be Serviced This PWS requires a contractor to provide services for the existing fire alarm and suppression systems installed at the facility. The contractor shall be responsible for all labor, tools, materials, and supervision necessary to perform maintenance, inspection, and potential repair or replacement services on the equipment detailed below. 2.1 Fire Alarm Control Panel Specifications The fire alarm system is controlled by an Olympia Electronics analogue addressable panel. All work must be compatible with this specific model and its associated components. Specification Details Equipment Type Analogue Addressable Fire Alarm Panel Manufacturer Olympia Electronics Model BSR-1004 Serial Number (S/N) 2938 System Type Analogue Addressable System Capacity 4 Loops Repeater Panel Compatible with BSR-1000 Repeater Panel Power Supply 220-240V AC, 50-60Hz, 130VA Max Enclosure Rating IP30 Country of Origin Greece 2.2 WATER BASED SUPPRESSION SYSTEMS These systems include but, are not limited to all associated equipment such as: tamper switches, pressure switches, flow switches, fire pumps, water reservoir tanks, liners, bladders, and air compressors. The Contractor s area of service responsibility starts at Main Control Valve (MCV) (e.g., Post Indicator valve) with its tamper switch (if provided) and applies to all water suppression systems downstream of MCV. 2.3 Compliance and Standards The contractor must ensure that all work performed, and any parts or components replaced, meet or exceed the original equipment manufacturer (OEM) specifications and comply with the following European standards to which the panel is certified, as well as all applicable local and national standards, regulations, and laws for the installation location. EN 54-2:1997+A1:2006 (Control and indicating equipment) EN 54-4:1997+A1:2002+A2:2006 (Power supply equipment) CE Mark (Notified Body: 1293) Construction Products Regulation (CPR) No: 1293 - CPR - 0658 Rev.1 Declaration of Performance (DoP) No: 921100400_59_001 The contractor is responsible for verifying all site conditions and equipment details prior to commencing work. 3.0 Scope of Work 3.1 Required Tasks Task Description 3.1.1 Semi-Annual System Inspection & Testing Conduct a complete functional and visual inspection of 100% of the fire alarm system components on a semi-annual basis. This includes testing every smoke detector, manual call point, and audible/visual notification appliance to ensure proper operation and communication with the main control panel, in line with UNI 11224 requirements for addressable systems. 3.1.2 Smoke Detector Cleaning As part of the ITM service, clean all addressable smoke detectors that indicate a 49% or higher analog level at the FACP. The contractor must download and provide a status report from the FACP before and after cleaning. 3.1.3 Preventive Maintenance Clean all system components as needed, check for environmental changes affecting device performance, and perform all manufacturer-recommended preventive maintenance actions during scheduled visits. 3.1.4 Emergency and Extraordinary Maintenance Provide emergency, on-call repair services to correct any system deficiencies or malfunctions. The contractor must respond and be onsite within 4 normal working hours after receipt of a service call. 3.1.5 Deficiency Correction Correct all deficiencies identified during inspection or testing. Minor deficiencies shall be corrected during the inspection visit. For major deficiencies requiring parts or extended labor, the contractor shall provide a written quote for repair within 5 business days of discovery. 3.2 Deliverables and Reporting Deliverable Description 3.2.1 ITM Service Schedule No later than ten (10) working days after award of the contract, the contractor shall submit a detailed schedule for all mandatory ITM services for approval. This schedule must be adhered to and updated as necessary. 3.2.2 ITM Service Report Within two (2) working days of completing any inspection, the contractor shall submit a detailed dual-language report. The report must include a list of all devices tested, their status (pass/fail), a description of any deficiencies found, and the corrective actions taken or recommended. 3.2.3 Certificate of Compliance Upon completion of the first semi-annual inspection and annually thereafter, the contractor shall provide a formal Certificate of Compliance stating that the fire alarm system is fully operational and meets all relevant EN 54 and local fire code standards. 3.2.4 Emergency / Extraordinary Service Report A service report shall be provided by the second working day following the completion of any emergency or extraordinary repair, detailing the nature of the fault, cause, description of work completed, hours expended, and materials used. 3.2.5 Weekly Service Submittals The contractor shall provide a weekly summary including a parts history summary, a work order tracker, and performance metrics. 4.0 Period of Performance The period of performance for this contract will be for one (1) Base Year of twelve (12) months, with the possibility of four (4) additional one-year Option Periods. The exercise of any Option Period will be at the sole discretion of the Government. Period Duration Start Date End Date Base Year 12 Months [Insert Start Date] [Insert End Date] Option Year 1 12 Months [Insert Date] [Insert Date] Option Year 2 12 Months [Insert Date] [Insert Date] Option Year 3 12 Months [Insert Date] [Insert Date] Option Year 4 12 Months [Insert Date] [Insert Date] 5.0 Contractor Qualifications The Contractor must meet the following minimum qualifications to be considered technically acceptable for this contract. 5.1 Corporate Experience The Contractor shall have a minimum of five (5) years of continuous corporate experience in the inspection, testing, maintenance, and repair of commercial-grade, analogue addressable fire alarm systems. 5.2 Technician Certification and Training All technicians must be fully trained and certified to work on analogue addressable fire alarm systems. 5.3 Key Personnel The Contractor shall appoint key personnel, including a primary and alternate point of contact, who are responsible for the performance of the work. 5.4 Language Proficiency All contractor personnel must be proficient in the local language. Key personnel who interact with the Contracting Officer's Representative (COR) must also be proficient in English. 5.5 Licensing and Insurance The Contractor must possess and maintain all required local, state, and national licenses and permits necessary to legally perform fire alarm system services. 5.6 Emergency Response Capability The Contractor must demonstrate the capability to meet the emergency response time requirements as specified in Section 3.1.4.

From Sources Sought posted on Mar 25, 2026

Notice history

1
  1. Sources Sought LATEST Posted Mar 25, 2026 View

Details

Solicitation number FA568226QA001
Notice ID 467a6203c46b4623a238e358b08a4bd8
Notice type Sources Sought
Set-aside No Set aside used
Place of performance CAMPIA TURZII
Archive date Apr 16, 2026

Award Information

Not yet awarded

Documents

1
View on SAM.gov

Contacts

primary
Delvin Talton

Email

secondary
Ali Elyousfi

Email

Agency

DEPT OF DEFENSE
DEPT OF THE AIR FORCE
U
S
AIR FORCES IN EUROPE
FA5682 31 CONS (UNIT 6102)

Place of Performance

CAMPIA TURZII 405100
ROU

Dates

Posted Mar 25, 2026 4 months ago
Last Updated Aug 06, 2026 1 day ago
Due Apr 01, 2026 4 months ago