Contacts, documents and full notice history are available with a subscription.
Sources Sought NONE Expired 1 notice 1 document

F-16 Aircraft or larger painter module F16AircraftPaintingModule

Solicitation F16AircraftPaintingModule Copied Notice ID 569d5368ada040129d86d703ac5cf3b9 Copied DEPT OF DEFENSE — W7N2 USPFO ACTIVITY TXANG 149
SAM.gov
Posted
Jul 02, 2025
Deadline
Jul 22, 2025
Set-aside
NONE
NAICS
336413
PSC
1680

Summary

AI-generated · Aug 24, 2025

Corrosion facility insert must comply with all requirements of UFC 4-211-02 Aircraft Hangar Paint requirements (dated 1 December 2012). The hangar will not be used for aircraft washes or media blasting. The insert should be able to fit an F-16 aircraft or larger and must include an air shower for egress. The system must maintain facility temperatures and humidity in accordance with Technical Order 1-1-8, paragraph 5.5.4, and is to be located in the San Antonio climate region. The insert must fit within a hangar bay measuring 73 11 5/8 wide, 73 4 deep and 140 tall; the door is a 3-part sliding door 61 3 wide. The building has nearby natural gas, electrical, and water supplies.

Two informational questions accompany the request: what is the largest aircraft that can be safely maintained in this area, and what are the expected power requirements for this facility?

The requirements for the corrosion facility insert is as follows: The insert must comply with all of the requirements of the Aircraft Hangar Paint requirements of the Unified Facilities Criteria 4-211-02 dated 1 December 2012. The hangar will not be used for aircraft washes or media blasting. The insert should be able to fit an F-16 Aircraft or larger. The facility requires an air shower for egress of the insert. The system should be able to maintain facility temperatures and humidity requirements in accordance with Technical Order 1-1-8 paragraph 5.5.4. The system will be located in the San Antonio Climate. The Insert should fit within a hangar bay that is 73 11 5/8 wide, 73 4 deep and 140 Tall (see attached diagram). The door is a 3 part sliding door that is 61 3 Wide. The building has natural gas, electrical and water supplies available nearby. The questions we have are as follows: What is the largest aircraft that can be safely maintained in this area? What are the expected power requirements for this facility?

From Sources Sought posted on Jul 02, 2025

Notice history

1
  1. Sources Sought LATEST Posted Jul 02, 2025 View

Details

Solicitation number F16AircraftPaintingModule
Notice ID 569d5368ada040129d86d703ac5cf3b9
Notice type Sources Sought
Product / Service (PSC) 1680
NAICS 336413
Set-aside No Set aside used
Place of performance DWG, Texas
Archive date Aug 06, 2025

Award Information

Not yet awarded

Documents

1
View on SAM.gov

Contacts

primary
Capt Derek Guedes

Email

Phone

Agency

DEPT OF DEFENSE
DEPT OF THE ARMY
NATIONAL GUARD BUREAU
W7N2 USPFO ACTIVITY TXANG 149

Place of Performance

DWG, Texas 78236
USA

Dates

Posted Jul 02, 2025 1 year ago
Last Updated Aug 06, 2026 1 day ago
Due Jul 22, 2025 1 year ago