Environmental Particle Counter PANHCA-25-P-0000-009816
Summary
AI-generated · Aug 24, 2025Market research to identify responsible sources capable of providing an Environmental Particle Counter for the Public Health Command at JBSA Fort Sam Houston, Texas, to determine if the effort can be competitively funded or set aside for small businesses. This is not a solicitaiton and does not commit the government to contract; responses are for planning purposes only and do not guarantee any future opportunity or reimbursement for responding.
Required device specifications include: measures particle sizes from 0.1 to 15 micrometers; aerosol concentration range from 0.001 to 150 mg/m³; simultaneously display PM1, PM2.5, respirable, PM10, and total particles; flow rate of 3.0 L/min with flow accuracy within ±5%; operational temperature range of 32 to 120 degrees Fahrenheit and relative humidity from 0 to 95% non-condensing; and conformity to recognized standards (ASTM, ISO, CSA, UL, NFPA, etc.), including MIL-STD requirements if applicable. The notice also specifies opportunities for small-business participation (e.g., 8(a), SDVOSB, HUBZone, WOSB) during market research.
The purpose of this sources sought notice is to conduct market research to determine if responsible sources exist by determining if this effort can be successfully competed and/or set-aside for Small Businesses. The proposed North American Industry Classification System (NAICS) Code is 334519-Other Measuring and Controlling Device Manufacturing the size standard is 600 employees. The Government will use this information to determine the best acquisition strategy for this procurement. The Government is interested in all small businesses to include 8(a), Service-Disabled Veteran- Owned, HubZone, and Women-Owned small business concerns. Medical Readiness Contracting Office - West JBSA Fort Sam Houston, Texas, is seeking potential sources to provide Environmental Particle Counter. The Government s requirement for Environmental Particle Counter for Public Health Command, Brooke Army Medical Center, JBSA Fort Sam Houston, Texas. All listed salient characteristics are applicable to Environmental Particle Counter are listed below: Particle size 0.1 to 15 um Aerosol concentration 0.001 to 150 mg/mc3 Simultaneously Display PM1, PM 2.5, respirable, PM10 and total particles Flow rate of 3.0 L/min Flow accuracy of +/- 5% Operational temperature of 32-to-120-degree F Operational Humidity of 0 to 95% RH, non-condensing Conformance to National/International standards such as ASTM, ISO, CSA, UL, NFPA, etc. Conformance to MIL-STDs if they are required This is not a solicitation. This information is for planning purposes only and is not to be construed as a commitment by the Government, implied or otherwise, to issue a solicitation or award a contract. Contractors responding to this source sought notice are advised their response does not ensure participation in future solicitations or contract awards. The Government will not reimburse any company or individual for any expense associated with preparation or participation in this research. Interested parties should e-mail responses to wayne.v.thompson3.civ@health.mil. All responses must be received by 14 July 2025-10:00AM CST
From Sources Sought posted on Jul 03, 2025Notice history
1-
Sources Sought LATEST Posted Jul 03, 2025
Details
Award Information
Not yet awarded
Contacts
Phone
Agency
Place of Performance
USA