Elevator Replacement Bldg. 246 W91QF426_Elevator
Summary
AI-generated · Aug 07, 2026Demolish and replace the existing machine-room-less elevator in Building 246, including all associated equipment and the support structure. Provide the record drawings for the most recent renovation and elevator repairs as part of the bid package.
Install a hydraulic, holeless, roped, single-jack, cantilever, passenger elevator with a 4,500 lb capacity and three front openings, 24 ft 3 in of travel, with doors opening at 100 fpm. The system must be 100% non-proprietary to ensure future maintenance can be performed by any qualified technician, and must comply with ANSI A17.1-2016.
- The building 246 requires a full demolition and replacement of its’ existing MRL elevator and associated equipment and support structure. The record drawings for the most recent renovation and elevator repairs shall be provided in this solicitation. The new elevator shall be installed with a 100% non-proprietary system, being that when future maintenance is required, any elevator repair technician has the capability of performing repairs. The contractor shall provide 3 front openings with 24’3” of travel that opens at 100 FPM. The new elevator shall be hydraulic, holeless, roped, single jack, cantilever, passenger elevator with a 4,500 lb capacity. The contractor shall comply with ANSI A17.1-2016 requirements.
From Solicitation posted on Aug 07, 2026Notice history
1-
Solicitation LATEST Posted Aug 07, 2026
Details
Award Information
Not yet awarded
Contacts
Phone
Phone
Agency
Place of Performance
USA