AI-generated · Apr 16, 2026

Cryogen-free dilution refrigerator system (UTQMD) designed as a cryostat with an integrated high-field magnet to reach ultralow base temperatures below 10 mK. Precool to 4 K with a helium-4 pulse tube and reach sub-10 mK using a He-3/He-4 dilution stage, enabling electronic transport and optical spectroscopy of two-dimensional heterostructure devices and RF dielectric-loss characterization with high-Q microwave resonators for superconducting qubit materials, at temperatures under 10 mK. Target cooling power is typically about 14 μW on the experimental flange at 20 mK.

The instrument must be cryogen-free (dry) and include two separate vacuum and radiation shield sets to support the two measurement modalities. It should be engineered for safe, user-friendly operation (hardware and control software) and demonstrate a proven track record of low-maintenance, low-downtime operation, with access for general users in a NSRC.

This is a pre-solicitation notice for Dilution Rerigerator an ultralow temperature quantum materials/devices measurement system (UTQMD) for the Center for Functional Nanomaterials (CFN) & the Codesign Center for Quantum Advantage (C2QA) at Brookhaven National Laboratory. The UTQMD instrument, hereafter referred to as Instrument shall be designed as a cryostat with an integrated high-field magnet, providing an ultralow base temperature. The system uses a helium-4 pulse tube to precool to 4K and a helium-3/helium-4 mixture to reach <10 mK temperature. The low temperature helps to minimize thermal fluctuations and thus improve the quantum coherence of the qubits/enable to observe quantum phenomena such as superconductor, exciton condensate physics. It shall support (1) electronic transport and optical spectroscopy of two-dimensional heterostructure devices and (2) RF dielectric-loss characterization using high-Q microwave resonators for superconducting qubit materials both at temperatures < 10 mK, with expected cooling power of (typical 14 ?W) on the experimental flange at 20 mK. The UTQMD should be a cryogen-free ( dry ) dilution refrigerator system and should include two separate vacuum and radiation shield set to support these two measurements. As an instrument offered to general users in a NSRC, the Instrument shall be engineered for safe, user-friendly operation (hardware and control software) and demonstrate a proven track record of low-maintenance, low-downtime operation.

From Presolicitation posted on Apr 15, 2026

This is a pre-solicitation notice for Dilution Rerigerator an ultralow temperature quantum materials/devices measurement system (UTQMD) for the Center for Functional Nanomaterials (CFN) & the Codesign Center for Quantum Advantage (C2QA) at Brookhaven National Laboratory. The UTQMD instrument, hereafter referred to as Instrument shall be designed as a cryostat with an integrated high-field magnet, providing an ultralow base temperature. The system uses a helium-4 pulse tube to precool to 4K and a helium-3/helium-4 mixture to reach <10 mK temperature. The low temperature helps to minimize thermal fluctuations and thus improve the quantum coherence of the qubits/enable to observe quantum phenomena such as superconductor, exciton condensate physics. It shall support (1) electronic transport and optical spectroscopy of two-dimensional heterostructure devices and (2) RF dielectric-loss characterization using high-Q microwave resonators for superconducting qubit materials both at temperatures < 10 mK, with expected cooling power of (typical 14 ?W) on the experimental flange at 20 mK. The UTQMD should be a cryogen-free ( dry ) dilution refrigerator system and should include two separate vacuum and radiation shield set to support these two measurements. As an instrument offered to general users in a NSRC, the Instrument shall be engineered for safe, user-friendly operation (hardware and control software) and demonstrate a proven track record of low-maintenance, low-downtime operation.

From Presolicitation posted on May 01, 2026

Notice history

2
  1. Presolicitation Posted Apr 15, 2026
  2. Presolicitation LATEST Posted May 01, 2026
    • Response Deadline: May 01, 2026Jun 01, 2026

Details

Solicitation number BSA476517
Notice ID 438cb35310d548539edd4090700381a3
Notice type Presolicitation
Product / Service (PSC) 6640
NAICS 334516
Set-aside No Set aside used
Place of performance Upton, New York
Archive date May 16, 2026

Award Information

Not yet awarded

Documents

No files available

View on SAM.gov

Contacts

primary
Mark Brock

Email

Phone

Agency

ENERGY, DEPARTMENT OF
ENERGY, DEPARTMENT OF
BROOKHAVEN NATL LAB -DOE CONTRACTOR

Place of Performance

Upton, New York 11973
USA

Dates

Posted Apr 15, 2026 3 months ago
Last Updated Aug 06, 2026 1 day ago
Due May 01, 2026 3 months ago