CGC STURGEON BAY WATER MIST FIRE SUPRESSION TESTING WITH UPDATE SOW 70Z08526Q0000855
Summary
AI-generated · Nov 22, 2025Perform annual testing and maintenance of the Hi-Fog water mist fire suppression system on the CGC Sturgeon Bay OPFAC 17509, located in Bayonne, NJ. Tasks include setting up the water mist system for testing, conducting the full system test, and returning the system to normal operation, ensuring all connections, fittings, and equipment within the system function correctly.
The contractor must be a Hi-FOG certified technician and renew 29 bottles, using MPC guidance (R-A-13380, R-M-13373, R-C-14526) as the basis for testing and documentation. Any discrepancies must be noted, and corrections should be performed only if there is no additional cost to the government; if a discrepancy would incur costs beyond the quote, it must be routed to the customer for approval before proceeding. Proposals are requested via RFQ for a firm-fixed-price award under simplified procedures, with responses due by the stated deadline.
This is a combined synopsis/solicitation This is a combined synopsis/solicitation for commercial items/services prepared in accordance with the format in FAR Subpart 12.6 as supplemented with additional information included in this notice. Request for Quotations number is 70Z08526Q0000855 and is issued as a request for quotations (RFQ). This announcement constitutes the only solicitation; quotations are being requested, and a written solicitation will not be issued. This Request for Quotations incorporates provisions and clauses in effect through Federal Acquisition Circular 2005-65 dated January 29, 2013. The NAICS Code is 336611. The small business size standard is 1250. This is a totally small business set aside. All responsible sources may submit proposals that will be considered by the agency. The contract will be awarded on a firm-fixed-price basis using simplified acquisition procedures in accordance with FAR Part 13.5. All responses from interested vendors must be received on/before 0800 Pacific Time, November 28th, 2025, and will be reviewed by the Government. The United States Coast Guard Surface Force Logistics Center has a requirement for the following: Contractor shall provide parts requested for USCGC STURGEON BAY Fire Suppression System Testing: STATEMENT OF WORK CGC STURGEON BAY OPFAC: 17509 LOCATIONS: Bayonne, NJ EQUIPMENT: Hi-Fog Water Mist Fire Suppression System COMPONENT AFFECTED: ANNUAL INSPECTION OF SYSTEM/ Renewal of 29 Bottles and certified MPC: R-A-13380, R-M-13373, R-C-14526 Contractor must be HI-FOG certified Technician. Contractor must set up water mist system for testing; complete the water mist system test; and place water mist system back in normal operation once test is completed. Contractors must ensure all connections, fittings, and equipment within the water mist system are operating correctly as well. Contractors shall use MPC R-A-13380, R-M-13373, R-C-14526 as guidance. Any discrepancies found shall be noted; and corrected only if no other cost is needed. If any discrepancy causes cost outside the quote, this shall be routed through customer before discrepancy is corrected. POP: 01DEC25-15DEC25 LOCATION/POC: MCKM Thaddeus Brandt Engineer Petty Officer USCGSC Sturgeon Bay 85 PORT TERMINAL BLVD, SLIP 3 BAYONNE, NJ 07002 US (201) 912-7910 (work) (631) 655-4034 (personal)
From Combined Synopsis/Solicitation posted on Nov 21, 2025This is a combined synopsis/solicitation This is a combined synopsis/solicitation for commercial items/services prepared in accordance with the format in FAR Subpart 12.6 as supplemented with additional information included in this notice. Request for Quotations number is 70Z08526Q0000855 and is issued as a request for quotations (RFQ). This announcement constitutes the only solicitation; quotations are being requested, and a written solicitation will not be issued. This Request for Quotations incorporates provisions and clauses in effect through Federal Acquisition Circular 2005-65 dated January 29, 2013. The NAICS Code is 336611. The small business size standard is 1250. This is a totally small business set aside. All responsible sources may submit proposals that will be considered by the agency. The contract will be awarded on a firm-fixed-price basis using simplified acquisition procedures in accordance with FAR Part 13.5. All responses from interested vendors must be received on/before 0800 Pacific Time, December 29th, 2025, and will be reviewed by the Government. The United States Coast Guard Surface Force Logistics Center has a requirement for the following: Contractor shall provide parts requested for USCGC STURGEON BAY Fire Suppression System Testing: STATEMENT OF WORK CGC STURGEON BAY OPFAC: 17509 LOCATION: Bayonne, NJ EQUIPMENT: Hi-Fog Water Mist Fire Suppression System COMPONENT AFFECTED: 5yr and ANNUAL INSPECTION OF SYSTEM/ Renewal of 29 Bottles and certified MPC: R-A-13380, R-M-13373, R-C-14526 Contractor must be HI-FOG certified Technician. Contractor must set up water mist system for testing; complete the water mist system test; and place water mist system back in normal operation once test is completed. Contractor must ensure all connections, fittings, and equipment within the water mist system are operating correctly as well. Contractor shall use MPC R-A-13380, R-M-13373, R-C-14526 as guidance. Replacement Parts to be included in 5-Year Annual Inspection 1 - PNEUMATIC REPAIR KIT WITH SILENCER (G40090) 1 - HYDRAULICREPAIR KIT (G40095) 30 - HOSE 36INCH 8MM FOR GPU (UU1168) 1 - HOSE ASSEMBLY - N2 REGULATOR (A20079.1) 2 - FILTER WATERFILTER R1 1/2, 60-MICROMETER (E31048) 1 - LOW PRESSURE FRESH WATER SAFETY VALVES (M-0010165) 2 - SVM20 DNV VALVEREBUILD KITS (V14020) Any discrepancies found shall be noted; and corrected only if no other cost is needed. If any discrepancy causes cost outside the quote, this shall be routed through customer before discrepancy is corrected. POP: 22DEC2025-29DEC2025 LOCATION/POC: MCKM Thaddeus Brandt Engineer Petty Officer USCGSC Sturgeon Bay 85 PORT TERMINAL BLVD, SLIP 3 BAYONNE, NJ 07002 US (201) 912-7910 (work) (631) 655-4034 (personal)
From Combined Synopsis/Solicitation posted on Dec 11, 2025Notice history
2-
-
Combined Synopsis/Solicitation LATEST Posted Dec 11, 2025View changes (3)
- Title: CGC STURGEON BAY WATER MIST FIRE SUPRESSION TESTING → CGC STURGEON BAY WATER MIST FIRE SUPRESSION TESTING WITH UPDATE SOW
- Description: Description was updated
- Response Deadline: Nov 28, 2025 → Dec 19, 2025