CCD camera for time-resolved spectroscopy N00173-25-Q-1301258002
Summary
AI-generated · Aug 25, 2025A sole-source purchase is planned for an intensified CCD camera tailored for time-resolved spectroscopy to support nanosecond-dynamics research across programs such as matrix-embedded nanoparticle catalysts and underwater plasma studies. The camera must meet strict specs: a quartz window, spectral response from 180 to 920 nm, peak quantum efficiency over 10% at room temperature, gate width under 50 ns, at least a 1024×255 pixel array with pixel size under 30 µm, frame rate below 20 fps, gain above 500, and repetition rate under 3 µs. The award will be made to Andor Technology Inc. without a formal competitive solicitation.
Interested parties may submit capability statements demonstrating their ability to meet these requirements; however, responses are intended only to assess whether competition would be advantageous. Information provided will be used to determine whether to conduct a competitive procurement, and no reimbursement will be provided for submission costs. The procurement will be conducted using Simplified Acquisition Procedures (FAR 13.106-1(b)) for purchases not exceeding $250,000.
NRL NOTICE OF INTENT TO AWARD A SOLE SOURCE This Notice of Intent is not a request for competitive proposals. This is not a solicitation or request for offers. No solicitation package is available and email requests will not be honored. Only one responsible source and no other supplies or services will satisfy agency requirements. The Naval Research Laboratory (NRL) intends to award a sole source Purchase Order to Andor Technology Inc. This requirement is for the purchase of an intensified CCD camera for time-resolved spectroscopy. The instrument will support ongoing efforts in matrix embedded nanoparticle catalysts, underwater plasma research, and many other existing programs providing nanosecond dynamics of solvated electrons, small molecules, biological and biomimetic species, polymers, materials and biomaterials for sensing, energy storage and conversion, and photonic applications. The spectrometer must be equipped with a quartz window, have a spectral range 180-920nm, peak quantum efficiency > 10% at room temperature, minimum gate width of < 50ns, minimum 1024x255 pixel array, < 30 micron pixel size, < 20 fps frame rate, gain of > 500, and < 3 microsecond repetition rate. The North American Industry Classification System Code (NAICS) for this requirement is 334516 with size standard of up to 1000 employees, Small The Federal Supply Code (FSC) / Product Service Code (PSC) procurement is 6640. This purchase will be made utilizing Simplified Acquisition Procedures in accordance with: Federal Acquisition Regulation (FAR) Part 13.106-1(b) for purchases not exceeding the simplified acquisition threshold of $250,000. Interested parties may identify their interests and capability to respond to this requirement in accordance with the posted opening and closing dates. Any response to this notice must show clear and convincing evidence that competition would be advantageous to the Government. Information received will be considered solely for the purpose of determining whether or not to conduct a competitive procurement. A determination by the Government not to compete this proposed purchase order based upon response to this notice is solely within the discretion of the Government. No reimbursement for any cost connected with providing capability information will be provided. Please reference this Notice of Intent number, N00173-25-Q-1301258002 on your correspondence and in the Subject line of your email. Closes 8/26/25 4pm ET
From Special Notice posted on Aug 19, 2025Notice history
1-
Special Notice LATEST Posted Aug 19, 2025
Details
Award Information
Not yet awarded
Contacts
Agency
Place of Performance
USA