AI-generated · Aug 24, 2025Renovate Building 2 for a Pharmacy at the Northampton Veterans Administration Hospital, with scope focused on interior renovations but allowing exterior work to preserve the historic exterior. Exterior tasks include reviewing and designing egress pathways (doors, ramps, emergency stairs), improving the building envelope, and repairing masonry-related conditions; windows will be replaced as part of the design.
The design team must include a Physical Security and Resiliency component with six required specialists (a certified physical security specialist for risk/vulnerability, CPTED, and ATFP; a control systems cybersecurity specialist knowledgeable in RMF; a certified physical security specialist for electronic security systems; a certified ICT specialist for networking and cabling; a certified systems integrator for HSPD/PPD-21; and a licensed professional structural engineer trained in blast design). These specialists must be part of the design team during the concept phase, and their resumes and the firm qualifications must be submitted to the VA Project Manager for review before concept work begins. The VA provides the Fire Protection Engineer for the Independent Fire Review, and the A/E must address comments from that review. Deliverables include full condition analysis, engineering calculations, design documentation and options, quantity and cost estimates, bid schedule, construction schedule, and a design documentation/report.
631-25-002 Renovate Building 2 for Pharmacy RFIs Received Paragraph A. INTRODUCTION on page 1 indicates that the scope to be performed consists of interior spaces, however the design service list on page 3 indicates that Building 2 is part of the Northampton Veterans Administration Hospital Historic District and therefore care must be made with exterior changes to remain close to historical appearances. Please clarify, does scope include exterior improvements or is all work expected to be interior for the Building 2 renovation? VA Response: Some exterior work expected. SOW has following line items regarding exterior: Review and design of building egress pathways (i.e., entry doors, rear doors, ADA ramps, emergency egress stair towers, etc.) Review of exterior walls to improve envelope performance. Repairing the building envelope will be a part of this design as there are known issues with the masonry, windowsills and lintels, and other infrastructure. Replacement of existing windows. Professional Qualifications listed on page 6 state that the design firm must provide a Physical Security team member and resume as part of the submission. Please advise if this a low-voltage security designer or otherwise. The role of Physical Security is a bit ambiguous. VA Response: Physical Security team member must be familiar with the PSRDM and meet the qualifications in section 1.8 of the manual: In order to meet the physical security and resiliency requirements of this manual, as appropriate to the scope of the project, the design team must include: (1) a certified physical security specialist with an emphasis on risk and vulnerability assessments, physical security design and CPTED, and anti-terrorism force protection; (2) a control systems cybersecurity specialist with in-depth knowledge of the Risk Management Framework; (3) a certified physical security specialist with an emphasis on Electronic Security Systems; (4) certified information and communications technology (ICT) specialist with an emphasis on networking and cabling; (5) a certified systems integrator specialist with an emphasis on HSPD/PPD-21 integrations; and, (6) a licensed professional structural engineer who has specialized training in blast design and analysis (structural blast specialist). These specialists must be part of the design team during the concept phase of any project. The rsum of the specialist must be submitted to the VA Project Manager (PM), local facility equivalent, or Contracting Officer Representative for review and approval prior to the concept phase of the project. The qualifications of the firm for whom the specialist works must also be submitted with the rsum. The professional qualifications that all specialists must comply with PHYSICAL SECURITY & RESILIENCY DESIGN MANUAL October 1, 2020 Revised 05-01-2024 INTRODUCTION 1-23 are found where their respective disciplines are addressed in Chapters 2, 6, 7, and 10 of this manual. Does the VA hire the Fire Protection engineer for the independent fire review or is that a consultant that should be included? VA Response: The VA provides the Fire Protection Engineer for the Independent Fire Review. See section 2.2 which states, [a] complete design including but not limited to determination and evaluation of existing conditions, necessary engineering calculation, necessary design work, independent fire safety/life safety review (Independent Fire Safety Review provided by VA. A/E is required to address comments from this review), IH Services, quantity and cost estimates, bid schedule, construction cost estimates, a proposed construction schedule, design analyses and calculations, a design documentation report, engineering considerations and options report shall be developed for this project.
From Special Notice posted on Jun 04, 2025Notice history
2-
Special Notice Posted Jun 04, 2025
-
Award Notice LATEST Posted Sep 16, 2025
Details
Award Information
Awardees
| Company Name | UEI | CAGE Code | Location |
|---|---|---|---|
| WBRC INC. | K8RHGGF73FH1 | 9EZ85 | PORTLAND |
Documents
8Contacts
Contract Specialist
Phone
Agency
Place of Performance