C1DA--AE Upgrade Fire Alarm Systems 538-26-200 36C25026R0028
Summary
AI-generated · Nov 08, 2025Upgrade Fire Alarm Systems at Chillicothe VA Medical Center requires Architect-Engineer design services for Project 538-26-200. The work is a design contract with a 300-day performance window from notice to proceed, and the total construction value is anticipated between $500,000 and $1,000,000 under a firm-fixed-price arrangement. The procurement is restricted to eligible SDVOSB firms and will select the most qualified firm through a formal A/E evaluation process; an RFP will be issued directly to the top candidate, with negotiations conducted under applicable FAR/VA regulations.
Key requirements include submitting a complete SF330 (Parts I and II) with an organizational chart and a Design Quality Management Plan, not to exceed 35 pages, plus resumes for specified key personnel and an organizational chart. The project team must include: one Professional Engineer or Licensed Architect with healthcare facility design and government project management QA/QC; one Electrical Engineer with Simplex fire alarm experience; one Fire Protection Engineer; one Certified Cost Engineer/Estimator; and one Certified Industrial Hygienist, all licensed and qualified. The evaluation emphasizes professional qualifications, specialized team experience (including five healthcare-design projects with at least three in Construction Period Services), firm capacity, past performance, knowledge of the project locality, Construction Period Services capability, and a commitment to using SDVOSB/VOSB and other small businesses as subcontractors. Additional requirements include SAM registration, EPLS verification, and E-Verify enrollment within 30 days of award. Submissions must address all factors and provide complete information to support the evaluation.
REQUEST FOR SF330 SUBMISSIONS 1. INTRODUCTION This procurement is a 100% Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside, in accordance with Public Law 109-461. The Department of Veterans Affairs is seeking Architect-Engineer (A/E) Design Services for: Project 538-26-200: AE Upgrade Fire Alarm Location: Chillicothe VA Medical Center, State Route 104, Chillicothe, Ohio 45601 Note: This announcement is not a Request for Proposal (RFP). A solicitation package will not be issued via Contracting Opportunities. Instead, an RFP will be issued directly to the most highly qualified firm, with negotiations conducted in accordance with Federal Acquisition Regulation (FAR) Subpart 36.2. The anticipated A/E design services will be procured in accordance with the Selection of Architects and Engineers Act (Public Law 92-582), FAR Subpart 36.2, and VA Acquisition Regulation (VAAR) Subpart 836.6. 2. PROJECT DESCRIPTION The objective is to provide A/E services in support of Project 538-26-200: AE Upgrade Fire Alarm at the Chillicothe VA Medical Center. Period of Performance: 300 calendar days from Notice to Proceed Estimated Construction Magnitude: Between $500,000 and $1,000,000 Contract Type: Firm-Fixed-Price NAICS Code: 541310 - Architectural Services Business Size Standard: $12.5 million 3. ELIGIBILITY REQUIREMENTS In accordance with VAAR 819.7003 (Deviation), at the time of SF330 submission and at the time of contract award, offerors must certify to the Contracting Officer that they are: A Service-Disabled Veteran-Owned Small Business (SDVOSB) eligible firm; A small business concern under the NAICS code assigned to this acquisition; Certified and listed in the SBA Small Business Search (SBS) database at https://search.certifications.sba.gov, in accordance with 13 CFR 128. If registration is required, firms must visit https://certifications.sba.gov to complete the process. Additionally, all eligible firms must be registered and active in the System for Award Management (SAM) at https://sam.gov to be considered for evaluation and award. Excluded Parties List System (EPLS): Contractors must verify that all individuals proposed under this contract are not listed in the EPLS at www.sam.gov, in accordance with Sections 1128 and 1128A of the Social Security Act. Certification of EPLS compliance is required. E-Verify Requirement: In accordance with FAR 52.222-54, firms awarded a federal contract must enroll in E-Verify within 30 days of award and use the system to confirm employment eligibility of all new hires and employees assigned to the contract 4. EVALUATION FACTORS The Government intends to award a contract to the responsible offeror whose submission is determined to be most advantageous, based on the evaluation criteria outlined below. Evaluation Factor Weight Professional Qualifications necessary for satisfactory performance of required services. 15% Specific Experience and Qualifications of personnel proposed for assignment to the contract and their record of working together as a team. 20% Firm s Capacity. 15% Past Performance. 15% Location in the general geographical area of the project and knowledge of the locality of the project. 10% Construction Period Services. 15% The extent to which potential contractors identify and commit to the use of service-disabled Veteran-owned small businesses, Veteran-owned small businesses, and other types of small businesses as subcontractors. 10% Professional qualifications necessary for satisfactory performance of required services (weighting 15%) All key personnel listed below for whom resumes shall be provided are the minimum required and shall be shown on an organizational chart. Personnel may fill multiple roles if qualified. All architects and engineers performing work on this project are required to be licensed, registered or certified by a US State, the District of Columbia or a US territory. Personnel shall provide professional license jurisdiction of issue and license numbers and/or proof of licensure. Any additional staff beyond the below minimum key personnel being made available for work shall also be indicated on the chart. Proposed team member experience shall be relevant within the last three (5) years. Personnel Qualifications and Experience as required by this criterion shall be located in Section E Resumes of Key Personnel. Organizational Chart shall be located in Section D Organizational Chart. One (1) Professional Engineer or Licensed Architect with experience in: Healthcare Facility Design and Construction U.S. Government Project Management Quality Assurance and Quality Control (QA/QC) One (1) Electrical Engineer with experience in: Simplex Fire Alarms Healthcare Facility Design and Construction Proven experience with all related NFPA codes and standards One (1) Fire Protection Engineer Proven experience with all related NFPA codes and standards One (1) Certified Cost Engineer/Estimator with experience in: Healthcare Facility Design and Construction U.S. Government Projects One (1) Certified Industrial Hygienist Specific experience and qualifications of personnel proposed for assignment to the contract and their record of working together as a team (weighting 20%) Include specialized experience and technical competence with healthcare related designs. Demonstrate successful completion of five (5) separate designs, three (3) of which have entered Construction Period Services. List completion dates for professional services and/or construction for all projects. If completion dates are not available, provide a status update that includes a brief description of the project, including scope, size, cost, principal elements, special features, and relevance of the example project to this contract. Firm Experience as required by this criterion shall be located in Section F Example Projects. Federal Government CPARS may also be considered, in conjunction. Include specialized experience and technical competence with residential healthcare-related designs, including electrical distributions systems and fire alarm systems. All projects provided in the SF-330 must involve some effort or contribution from the prime firm (or former firm names as listed in Part II General Qualifications). Include no more than five (5) Government and/or private experience projects completed within the past eight (8) years that best illustrate specialized experience as listed above, with at least 95% of the design completed. Include at least three (3) of these projects having entered Construction Period Services. Firm s capacity (weighting 15%) Describe the firm s ability to accomplish the work in the required time, including existing workload from all private and public clients and awards with similar scope requirements that may limit capacity to perform project work expeditiously. Provide a list of current contractual obligations from all public and private clients of the firm and/or key personnel with periods of performance extending up to one (1) calendar year from SF330 submission. Provide project title, estimated construction costs (if applicable), and period of performance dates for the contractual obligations. Provide evidence supporting the firm s ability to perform work in the required time, such as execution of simultaneous task orders with construction costs equal to or greater than this solicitation. Past performance (weighting 15%) Past performance on contracts with Government agencies and private industry in terms of cost control, quality of work, and compliance with schedules. Offerors will be evaluated on past performance with Government agencies and private industry in terms of work quality, compliance with schedules, cost control, and stakeholder/customer satisfaction. Evaluating past performance and experience will include information provided via the Contractor Performance Assessment Reports System (CPARS) for projects listed in Section F of the SF-330 as well as any other projects contained in the database and may include review of information obtained via customer inquiries, other Government databases, and any other relevant other information available to the Government. Preferred to have past performance with Federal Government agencies. Location in the general geographical area of the project and knowledge of the locality of the project (weighting 10%) Project designated staff shall provide travel times from primary place of work to the Chillicothe VAMC. Project designated staff shall be assigned a score based on the criteria below. SF-330 shall achieve a score based on the average score of project designated staff. Examples of knowledge of the locality of the project include: knowledge of geographical features, climatic conditions, unusual or unique local construction methods, or previous work on the station. Greatest preference will be for locations within 1.5-hour travel time of the Chillicothe VA Medical Center. Preferred to have a physical presence within 3-hour travel time. Construction Period Services (weighting 15%) Experience in Construction Period Services to: Professional Field Inspections Review of Construction Submittals RFI Support Support Construction Contract Changes to include Drafting Statements of Work and Cost Estimates The extent to which potential contractors identify and commit to the use of service-disabled Veteran-owned small businesses, Veteran-owned small businesses, and other types of small businesses as subcontractors (weighting 10%). Firms (Prime and Subcontractor(s)) shall be SBA Certified (aka VetCert) if SDVOSB or VOSB. To be considered, SDVOSB/VOSB firms must be listed in the SBA Certification database at https://search.certifications.sba.gov (see 13 CFR 128). All other small business firms shall be certified by SAM.gov or Fed Data Check. Estimated percent of project overall workload shall be designated for each firm (prime and sub). SDVOSB shall be given greatest preference. VOSB shall be given great preference. All other small businesses to be preferred. Important: To ensure a fair and comprehensive evaluation, the AE Evaluation Board requires complete and accurate information for all evaluation factors listed in this announcement. AE firms are strongly encouraged to elaborate on any evaluation factor that may not be fully addressed in Part I - Section A through Section G and Part II of the SF330. Firms should utilize Part I - Section H and/or attach additional sheets as necessary to clearly demonstrate their qualifications for each evaluation factor. Please also be mindful of the submission requirements outlined in Paragraph 7 below when preparing your responses. 5. SELECTION PROCESS In accordance with FAR subpart 36.6, submitted SF330s will be evaluated by the AE Evaluation Board based on the evaluation factors identified in this announcement. Following the initial evaluation, if the Board elects to conduct discussions or interviews, at least three of the most highly qualified firms will be selected for further consideration. Upon conclusion of discussions, the Board will reassess the qualifications of these firms using the same evaluation factors, taking into account both the original SF330 submission and any additional information provided during discussions. The Board will then recommend the firm determined to be the most highly qualified. 6. LIMITATIONS ON SUBCONTRACTING Per VAAR 852.219-75, VA Notice of Limitations on Subcontracting - Certificate of Compliance for Services and Construction (Deviation): The prime contractor may not pay more than 50% of the total contract amount to firms that are not certified SDVOSBs or VOSBs. Work subcontracted to similarly situated SDVOSB/VOSB firms counts toward the 50% requirement. Other Direct Costs (ODCs) may be excluded if not central to the acquisition. 7. SUBMISSION INSTRUCTIONS Interested and eligible firms must submit their SF330 packages as follows: Submission Deadline: December 9, 2025, by 10:00 AM (Local Time) Submission Method: Email only Recipient: Matthew Curtis, Contract Specialist Email: matthew.curtis1@va.gov Late submissions will not be accepted. A submission is considered late if received after the specified date and time. Each submission must include: One (1) original SF330, Parts I and II, including all consultants Part I, Section H must include: An organizational chart of the prime firm (excluding consultants) A Design Quality Management Plan Page Limitation: SF330 submissions must not exceed 35 total pages (8.5 x 11 ), excluding SF330 Part II and Past Performance documentation (e.g., CPARS reports). Note: Information incorporated by reference is not permitted. The SF330 form is available at: https://www.gsa.gov/forms-library/architect-engineer-qualifications 8. ADDITIONAL INFORMATION Faxed or telephone responses will not be accepted. No additional solicitation documents or project scope information are available. All inquiries must be submitted via email to matthew.curtis1@va.gov. Telephone inquiries will not be entertained. 9. POINT OF CONTACT Name: Matthew Curtis Title: Contract Specialist Email: matthew.curtis1@va.gov
From Presolicitation posted on Nov 07, 2025Updated as of: 11/25/2025 11:56 AM Solicitation: 36C25026R0028 Project: 538-26-200 AE Upgrade Fire Alarm Systems - Dayton VAMC Request for Information (RFI) Tracker with VA Responses KEY: Submitted RFI = Black VA RFI Response = Blue Regarding the subject solicitation, can you please confirm the estimated cost of construction is $500,000-$1,000,000 Confirmed. The estimated construction cost range is $500,000 to $1,000,000. Per the Presolicitation Notice on page 4, "Proposed team member experience shall be relevant within the last three (5) years." Please clarify which amount is correct- three years or five years? The correct timeframe is five (5) years. Page 4 of the Presolicitation Notice states that an "Organizational Chart shall be located in Section D- Organizational Chart", while page 7 states that "An organizational chart of the prime firm (excluding consultants)" should be provided with Section H. Please clarify if two (2) organizational charts should be provided, and please clarify what information each chart should contain. Only one organizational chart is required. It shall be included in Section D Organizational Chart, and should reflect the structure of the prime firm, excluding consultants, as stated on page 7. Please confirm that Part II forms should be included for all consultants in addition to the Prime. Confirmed. SF 330 Part II forms must be submitted for the prime firm and all proposed consultants. Which Contracting Office address is the correct one to list? The Presolicitation Notice on page 1 reads, "Department of Veterans Affairs, Network Contracting Office 10, 3140 Governor s Place Blvd. Suite 210, Kettering, OH 45409-1337 ". The SAM.gov Contracting Office Address lists, "VISN 10 CONSOLIDATED CONTRACTING, 4100 WEST 3RD STREET, DAYTON, OH 45428." Please use the following address as listed in the Presolicitation Notice: Department of Veterans Affairs Network Contracting Office 10 3140 Governor s Place Blvd., Suite 210 Kettering, OH 45409-1337 Per page 3 of the Presolicitation Notice, "Personnel shall provide professional license jurisdiction of issue and license numbers and/or proof of licensure." Is it enough to list the jurisdiction of issue and license numbers, or do we also have to provide proof of licensure? Listing the jurisdiction of issue and license numbers is sufficient; proof of licensure is not required. Per page 4 of the Presolicitation Notice, "Federal Government CPARS may also be considered, in conjunction." It is understood that attaching CPARS reports will not be counted toward our 35-page limit. What if we do not have CPARS reports to include for all of the projects? CPARS reports are not required for every project. If CPARS evaluations are not available, offerors may provide other relevant documentation or narrative descriptions to demonstrate past performance. The absence of CPARS will not disqualify a submission. Are we allowed to include a Cover Page, Cover Letter or Table of Contents? Would they be counted against the 35-page limit? Yes, offerors are permitted to include a Cover Page, Cover Letter, and Table of Contents as part of their submission. Please note that each of these elements will count toward the 35-page limitation.
From Presolicitation posted on Nov 25, 2025December 8, 2025 Solicitation: 36C25026R0028 Project: 538-26-200 AE Upgrade Fire Alarm Systems - Dayton VAMC The purpose of this document is to: Adjust the NAICS code from 541310 (Architectural Services) to 541330 (Engineering Services) with a business size standard of $25.5M. Adjust the submission Deadline: from 10:00AM on December 9, 2025 to 10:00AM on December 19, 2025. All other terms and conditions remain the same.
From Presolicitation posted on Dec 08, 2025Notice history
3-
Presolicitation Posted Nov 07, 2025
-
Presolicitation Posted Nov 25, 2025View changes (2)
- Title: C1DA--AE Upgrade Fire Alarm Systems 538-26-200 → C1DA--AE Upgrade Fire Alarm Systems 538-26-200 - VAMC CHILLICOTHE
- Description: Description was updated
-
Presolicitation LATEST Posted Dec 08, 2025View changes (3)
- Description: Description was updated
- Response Deadline: Dec 09, 2025 → Dec 19, 2025
- NAICS Codes: 541310 → 541330
Details
Award Information
Contacts
Contract Specialist
Phone
Agency
Place of Performance
Chillicothe, Ohio 45601