Bldg. 175 Replace Fuel Underground Storage Tank, NAS Lemoore, CA N62473-25-R-J514
Summary
AI-generated · Feb 04, 2026Replace the underground jet fuel storage tank at the B-175 Jet Engine Test Cell with a new 20,000-gallon, factory-fabricated, double-wall above-ground tank, including a platform and stairs, plus all related site work and utility modifications. Install a new concrete pad, tank footings, containment curb, a concrete fuel pipe trench with traffic-rated grating, electrical pull boxes, ductbank and conduits, and two new fuel pumps. Relocate indicated devices and piping (with new cathodic protection for underground piping), relocate the emergency stop panel and add a readout for the automatic tank gauge, and install stainless steel piping and valves to reestablish connections to the new tank. Add bollards around the tank/pad, install a light post, a fire hydrant, and an eyewash station, and perform all required testing and verification per the specification.
Demolition scope includes removing concrete above the underground tank to access excavation, removing and relocating existing devices, piping, and the emergency stop panel, and removing cathodic protection test wells, fiberglass sump, and the concrete collar. Remove the existing fuel pumps, associated equipment, and electrical boxes/conduits; excavate and fully remove the underground 20,000-gallon tank and its base; complete environmental cleanup and testing per requirements; remove the fire hydrant, valve assemblies, bollards, ductbank, conduits, and double-wall supply/return piping back to the building. Liquidated damages may apply for the underground-tank removal if not completed as required.
The intent of this project is to replace the underground jet fuel storage tank at the B-175 Jet Engine Test Cell with a new, double-wall, aboveground storage tank. Specific methods shall be as described below. Work Requirements: a. Construction: 1. Install new concrete pad, tank footings, and containment curb in accordance with the drawing requirements including piping and conduit penetrations. 2. Install a new 20,000 gallon factory fabricated, double wall, protected, above-ground jet fuel storage tank including platform and stairway as indicated on the drawing. 3. Install new concrete fuel pipe trench with traffic rated grating as indicated on the drawing. 4. Install new electrical pull boxes, concrete ductbank, and conduits as indicated on the drawing. 5. Install new two new fuel pumps in accordance with the pump schedule. 6. Relocate indicated devices and piping including new cathodic protection for underground piping. 7. Relocate existing emergency stop panel as indicated and add a new readout for the automatic tank gauge system. 8. Install new stainless steel piping and valves as indicated to re-establish all connections with the new above-ground tank. 9. Install bollards all the way around the new tank and pad area as indicated on the drawing. 10. Install new light post where indicated on the drawing, including switch near the stairwell. 11. Install new fire hydrant where indicated on the drawing. 12. Install a new eyewash station as indicated. 13. Perform all requisite equipment testing and verifications in accordance with specification requirements. b. Demolition: 1. Demolish and remove all concrete as indicated above the underground tank to provide access for excavation of the tank. 2. Remove existing devices and piping to be relocated as indicated on the drawing. 3. Remove existing emergency stop panel and associated conduit to be relocated as indicated on the drawing. 4. Remove existing cathodic protection test wells and associated cabling and anodes where indicated. 5. Remove existing fiberglass transition sump and concrete collar as indicated. 6. Remove the existing fuel pumps, associated devices, and electrical boxes and conduits as indicated. 7. Excavate and completely remove the 20,000 gallon underground jet fuel storage tank. This tank removal must be completed (out of the ground) by December 31st 2025. Liquidated damages may be assessed as detailed in Section 1.7 for this activity. 8. Remove the concrete base beneath the existing underground tank. 9. Perform all requisite clean-up and testing associated with the removal in accordance with all of the federal, state, and local environmental requirements. 10. Remove existing fire hydrant and associated piping as indicated. 10. Remove existing valve, valve box, pedestal type hose bib, and associated piping as indicated. 11. Remove existing bollards where indicated. 12. Remove existing concrete ductbank and conduits back to the building as indicated. 13. Remove existing double wall fuel supply and return pipes back to the building as indicated.
From Award Notice posted on Feb 03, 2026Notice history
1Details
Award Information
Award Notices
Posted: Feb 03, 2026
The intent of this project is to replace the underground jet fuel storage tank at the B-175 Jet Engine Test Cell with a new, double-wall, aboveground storage tank. Specific methods shall be as described below. Work Requirements: a. Construction: 1. Install new concrete pad, tank footings, and contai...
Awardees
| Company Name | UEI | CAGE Code | Location |
|---|---|---|---|
| WU & ASSOCIATES INC | MLSMLM5BFMW5 | 0P2R2 | Mount Laurel, NJ |
Contacts
Phone
Phone
Agency
Place of Performance
USA