BD Accuri C6 Plus System Flow Cytometer 36C24W25Q0258
Summary
AI-generated · Aug 24, 2025Provide a brand-name BD Accuri C6 Plus Flow Cytometer with blue and red lasers, two light-scatter detectors, and four fluorescence detectors with filters optimized for detecting FITC, PE, PerCP-Cy5.5, and APC. It must have 488 nm (blue) and 640 nm (red) laser excitation, a 10 x 75 m laser profile, forward and side scatter detection at the specified angles, four user-changeable optical filters (FL1 533/30 nm, FL2 585/40 nm, FL3 >670 nm, FL4 675/25 nm), fixed optical alignment, a 200-µm ID quartz flow cell, and the ability to detect particles down to 0.5 µm in size with a minimum 50 µL sample volume. Also include the BD CSampler Plus Software CD with the appropriate PMTs and filters for the BD Accuri C6, the standard filters for FL1–FL4, and related consumables such as waste and sheath bottles, a FACS CleanBottle, detergent bottle, peristaltic pump tubing, sheath and detergent, bottle filters, and the In-Line Sheath Filter.
Includes the BD Accuri C6 Plus System (660517) and a 3-year service Cont C6 Plus (Depot Repair) (661498), plus BD FACS Clean Solution 5 L, BD Sheath Additive, BD Detergent Solution Concentrate, BD Extended Flow Cell Clean Solution, CS&T RUO Beads 50 Test, Assy Tubing Pump Peristaltic, and a computer bundle HP Z2 Mini G5 C6 Plus (665008) with BD CSampler Plus (660519). Also provides service Cont CSampler Plus (Depot Repair) for 3 years (661499) and other CSampler Plus service coverage. The package is described as compact, portable, with pre-optimized detector settings to simplify operation for flow cytometry experiments.
This is a brand name purchase description. Items will be acceptable if they meet the below salient characteristics. Must have blue and red laser, two light scatter detectors, and four fluorescence detectorswith optical filters optimized for the detection of many popular fluorochromes, includingFITC, PE, PerCP-Cy5.5, and APC Must have 488 nm, 640 nm laser excitation optics Must have 10 x 75 m laser profile Must have light scatter detection 0, 13 (Forward) and 90, 13 (Side) Must have four colors, user-changeable optical filters: FL1 533/30 nm, FL2 585/40 nm,FL3 >670 nm and FL4 675/25 nm Must have fixed optical alignment Must have flow cell 200-m ID quartz capillary Must operate with 0.5 m minimum detectable particle size Must operate with 50 L minimum sample volume Must have BD CSampler Plus Software CD, 488 nM Laser (Blue), 640 nM Laser (Red),FL1 PMT, FL2 PMT, FL3 PMT, FL4 PMT, Standard Optical Filter 533/30 nm (FL1) forthe BD Accuri C6, Standard Optical Filter 585/40 nm (FL2) for the BD Accuri C6,Standard Optical Filter 670 nm LP (FL3) for the BD Accuri C6, Standard Optical Filter675/25 nm (FL4) for the BD Accuri C6, 2L Waste Bottle, 2L Sheath Bottle, FACS CleanBottle, Detergent Bottle, Peristaltic Pump Tubing, Sheath, Detergent, FACS clean SolutionBottle Filters (1 each), In-Line Sheath Filter (Accuri C6 Plus) Must have BD Accuri C6 Plus System (660517) Must have service Cont C6 Plus (Depot Repair) 3 Years (661498) Must have BD FACS Clean Solution 5L (340345) Must have BD Sheath Additive (660584) Must have BD Detergent Solution Concentrate (660585) Must have BD Extended Flow Cell Clean Solution (660586) Must have CS&T RUO Beads 50 Test (661414) Must have Assy Tubing Pump Peristaltic (659522) Must have Computer Bundle HP Z2 Mini G5 C6 plus (665008) Must have BD CSampler Plus (660519) Must have Service Cont C6 Plus (661498) Must have Service Cont CSampler Plus (Depot Repair) 3 Years (661499) Must have Service Cont CSampler Plus (661499) The BD Accuri C6 Plus flow cytometer is a compact, versatile, and highly portable system designed for ease of use. It features both blue and red lasers, along with two scatter detectors and four fluorescence detectors with interference filters optimized for FITC, PE, PerCP-Cy5.5, and APC detection. Its compact optical design, fixed alignment, and pre-optimized detector settings simplify operation. The low-pressure pumping system controls the fluidics, and the sheath-focused core enables event rates of up to 10,000 events per second, with sample concentrations exceeding 5 x 10^6 cells per mL. The BD CSampler Plus accessory further streamlines sample processing, making this instrument ideal for our experiments.
From Combined Synopsis/Solicitation posted on Jul 02, 2025Notice history
1-
Combined Synopsis/Solicitation LATEST Posted Jul 02, 2025
Details
Award Information
Not yet awarded
Contacts
Agency
Place of Performance
USA