Contacts, documents and full notice history are available with a subscription.
Solicitation SBA Due Soon 3 notices 2 documents

Bard Air Conditioner Replacement W36HY-B09 1301387097

Solicitation 1301387097 Copied Notice ID ba112fd90299493a9110b06993d698bf Copied DEPT OF DEFENSE — NAVSUP FLT LOG CTR SAN DIEGO
SAM.gov
Posted
Jul 22, 2026
Deadline
Jul 27, 2026
Set-aside
SBA
NAICS
238220
PSC
4130

Summary

AI-generated · Aug 07, 2026

Replace two non-functioning Bard W36HY-B09 3-ton wall-mount heat pump systems at the NPS Camp Roberts remote site (Buildings 1 and 2; Building 2 has three units, and the target is the rightmost unit when viewed from the back). Each 230V single-phase unit uses R-454B refrigerant and includes factory-approved electric backup heat strips. Tasks include removal of old equipment, setting and securing the new Bard units, reconnecting to existing electrical and low-voltage wiring, pressure testing and refrigerant- circuit commissioning, and verifying overall operation. Install the Bard units and compatible programmable thermostats per manufacturer specifications and codes; perform a full system startup and commissioning with airflow/temperature verification and demonstration of heating, cooling, and control functions to the on-site manager.

Initially issued as a sole-source/brand-name intent, the procurement has progressed to a formal competitive solicitation (N00244-26-Q-0070) with attached details and photos. Two of the six total A/C units are slated for replacement to address extreme heat conditions (over 100°F) and prevent heat stress. The close date was updated to Tuesday at 4:00 PM PST, and questions/answers are anticipated to be published the following Monday.

THIS IS A NOTICE OF INTENT TO AWARD A SOLE SOURCE CONTRACT or BRAND NAME AND IS NOT A REQUEST FOR COMPETITIVE QUOTES The Purpose of request is to replace two (2) non-functioning Air Conditioning (A/C) units at the NPS remote site located at Camp Roberts, CA. Tasks: The contractor shall perform the following task(s) as follows: Procurement and installation of two (2) new 3-ton Bard W36HY-B09 Wall-Mount Heat Pump packaged wall-mount heat pump systems, 230V single phase, utilizing R-454B refrigerant. Each system will include factory-approved electric backup heat strips for supplemental heating during colder outdoor conditions. Unit replacements will be performed on Building 1 and Building 2. Building two has three wall-mounted heat pumps. This will be the furthest one to the right when looking at the back of the building. Removal and disposal of existing equipment as needed, setting and securing new Bard units, reconnecting to existing incoming electrical power and existing low-voltage control wiring, pressure testing and commissioning refrigerant circuits, and verifying proper system operation. The contractor shall install the new Bard units and programmable thermostats in accordance with manufacturer specifications and all applicable codes. The contractor shall perform a full system startup and commissioning, including pressure testing, airflow/temperature verification, and demonstrating proper heating, cooling, and control functions to the on-site manager. See Notice of Intent for Additional information

From Special Notice posted on Jul 22, 2026

This solicitation is for Bard Air Conditioner Replacements W36HY-B09 at NPS remote site located at Camp Roberts, CA. See details in attached: 1) Solicitation N00244-26-Q-0070 2) Photos Bard HVAC Systems, Buildings 1 & 2 Field Lab High level background listed here. See Solicitation for full details 1.0 Background/Introduction: The Purpose of request is to for replace two (2) non-functioning Air Conditioning (A/C) units at the NPS remote site located at Camp Roberts, CA. 2.0 Scope: These units are imperative due to excessive temperatures in the Spring, Summer and Fall months exceeding 100F. Thus, preventing heat stress environment. Two of the 6 A/C units need to be replaced. 3.0 Tasks: The contractor shall perform the following task(s) as follows: 3.1 Procurement and installation of two (2) new 3-ton Bard W36HY-B09 Wall-Mount Heat Pump packaged wallmount heat pump systems, 230V single phase, utilizing R-454B refrigerant. Each system will include factory-approved electric backup heat strips for supplemental heating during colder outdoor conditions. Unit replacements will be performed on Building 1 and Building 2. Building two has three wall-mounted heat pumps. This will be the furthest one to the right when looking at the back of the building. 3.2 Removal and disposal of existing equipment as needed, setting and securing new Bard units, reconnecting to existing incoming electrical power and existing low-voltage control wiring, pressure testing and commissioning refrigerant circuits, and verifying proper system operation. 3.3 The contractor shall install the new Bard units and compatible programmable thermostats in accordance with manufacturer specifications and all applicable codes. The contractor shall perform a full system startup and commissioning, including pressure testing, airflow/temperature verification, and demonstrating proper heating, cooling, and control functions to the on-site manager.

From Solicitation posted on Aug 05, 2026

Updated to move close date to Tuesday 400pm PST Questions and Answers anticpated to be published Monday 8/10. This solicitation is for Bard Air Conditioner Replacements W36HY-B09 at NPS remote site located at Camp Roberts, CA. See details in attached: 1) Solicitation N00244-26-Q-0070 2) Photos Bard HVAC Systems, Buildings 1 & 2 Field Lab High level background listed here. See Solicitation for full details 1.0 Background/Introduction: The Purpose of request is to for replace two (2) non-functioning Air Conditioning (A/C) units at the NPS remote site located at Camp Roberts, CA. 2.0 Scope: These units are imperative due to excessive temperatures in the Spring, Summer and Fall months exceeding 100F. Thus, preventing heat stress environment. Two of the 6 A/C units need to be replaced. 3.0 Tasks: The contractor shall perform the following task(s) as follows: 3.1 Procurement and installation of two (2) new 3-ton Bard W36HY-B09 Wall-Mount Heat Pump packaged wallmount heat pump systems, 230V single phase, utilizing R-454B refrigerant. Each system will include factory-approved electric backup heat strips for supplemental heating during colder outdoor conditions. Unit replacements will be performed on Building 1 and Building 2. Building two has three wall-mounted heat pumps. This will be the furthest one to the right when looking at the back of the building. 3.2 Removal and disposal of existing equipment as needed, setting and securing new Bard units, reconnecting to existing incoming electrical power and existing low-voltage control wiring, pressure testing and commissioning refrigerant circuits, and verifying proper system operation. 3.3 The contractor shall install the new Bard units and compatible programmable thermostats in accordance with manufacturer specifications and all applicable codes. The contractor shall perform a full system startup and commissioning, including pressure testing, airflow/temperature verification, and demonstrating proper heating, cooling, and control functions to the on-site manager.

From Solicitation posted on Aug 07, 2026

Notice history

3
  1. Special Notice Posted Jul 22, 2026
  2. Solicitation Posted Aug 05, 2026
    • Title: Bard Air Conditioner Replacement W36HY-B09Bard Air Conditioner Replacements W36HY-B09 for NPS
    • Description: Description was updated
    • Notice Type: Special NoticeSolicitation
    • Response Deadline: Jul 27, 2026Aug 10, 2026
  3. Solicitation LATEST Posted Aug 07, 2026
    • Description: Description was updated
    • Response Deadline: Aug 10, 2026Aug 11, 2026

Details

Solicitation number 1301387097
Notice ID ba112fd90299493a9110b06993d698bf
Notice type Special Notice
Product / Service (PSC) 4130
NAICS 238220
Place of performance California
Archive date Aug 11, 2026

Award Information

Not yet awarded

Contacts

primary
Kyle Westover

Email

Phone

Agency

DEPT OF DEFENSE
DEPT OF THE NAVY
NAVSUP
NAVSUP GLOBAL LOGISTICS SUPPORT
NAVSUP FLC SAN DIEGO
NAVSUP FLT LOG CTR SAN DIEGO

Place of Performance

California 93451
USA

Dates

Posted Jul 22, 2026 2 weeks ago
Last Updated Jul 25, 2026 2 weeks ago
Due Jul 27, 2026 1 week ago