Contacts, documents and full notice history are available with a subscription.
Sources Sought SBA Expired 2 notices 1 document

B533--VANIHCS SPS Water Testing (VA-27-00000760) 36C25026R0060

Solicitation 36C25026R0060 Copied Notice ID e530a2aa684f4c908ccca740126536e0 Copied VETERANS AFFAIRS, DEPARTMENT OF — 250-NETWORK CONTRACT OFFICE 10 (36C250)
SAM.gov
Posted
Apr 07, 2026
Deadline
Apr 07, 2026
Set-aside
SBA
NAICS
541380
PSC
B533

Summary

AI-generated · Apr 08, 2026

Provide ANSI/AAMI ST108:2023–compliant water testing and reagents for the Sterile Processing System at the Marion, Fort Wayne, and Jackie Walorski VA sites. The contractor will collect samples, have them processed at an Indiana-certified laboratory, calibrate the conductivity/resistivity meter monthly, and deliver a formal water analysis report. They will serve as the water testing SME, drive corrective actions for out-of-range results, and perform routine monthly, quarterly, and yearly tests (including performance qualification and follow-up testing) per the ST108:2023 and VA contract/SOW. On-site work includes training VA staff, providing a handheld resistivity meter and pH/hardness dipsticks, and supplying an operations manual and required testing procedures.

Qualifications include at least five years’ experience in water treatment testing for medical centers, ownership or access to a state-certified laboratory supervised by a Professional Chemist, and references from three recent similar customers. Respondents should include three past contracts, a public price list, and indicate any items to be provided open market versus on a contract. The notice seeks information from VA SDVOSB, VOSB, and SB concerns, and requires SAM registration and, for SDVOSB/VOSB, VA certifications. This is an information-gathering Sources Sought; no contract will be awarded from this notice.

THIS IS A SOURCES SOUGHT ANNOUNCEMENT FOR INFORMATION ONLY. THIS IS NOT A SOLICITATION FOR PROPOSALS AND NO CONTRACT WILL BE AWARDED FROM THIS ANNOUNCEMENT. The purpose of this notice is to conduct market research and obtain information from qualified businesses with special interest in seeking: VA certified Service-Disabled Veteran owned Small Business (SDVOSB), VA certified Veteran Owned Small Business (VOSB) and Small Business (SB) concerns. No solicitation is being issued at this time. All information submitted in response to this announcement is voluntary; the Government will not pay for information requested nor will it compensate any respondent for any cost incurred in developing information provided to the Government. The Department of Veteran Affairs, Northern Indiana Health Care System (NIHCS) has a requirement for Water Testing and Reagents for the sterile processing system (SPS) at the Marion, Fort Wayne, and Jackie Walorski VA sites. The appropriate NAICS Code 541380, Testing Laboratories, Size Standard $16.5 Million Responses: Please submit your response in accordance with the following instructions: Responses shall be no more than 10 pages in length. Responses are due by 4/22/2026 at 15:00 PM EST. Responses shall be submitted via email to eric.sweatt@va.gov. Emails cannot exceed 5mb Subject line of the Email shall include this Sources Sought Notice Number Firm Name NIHCS Water Testing and Reagents for the SPS Services. If your response contains proprietary information you will place Proprietary Information in front of the Sources Sought Notice Number. No marketing materials are allowed as part of this Sources Sought Notice. The Government will not review any other information or attachments included in your submission that is not listed herein or exceeds the 10-page limitation. Contractors Federal Supply Schedule Contract that carries the desired services If you do not have a Federal Supply Schedule contract, you shall state open market Provide the Schedule Provide expiration date of your Contract Provide your GSA/FSS/SAC Contract Number Provide the SIN for water testing and reagents for SPS services If any of the items are not on your GSA/FSS contract, you will mark which items are open market. Contractor Point of Contact to include: Name Title Phone Email Company Information to include: Name Address SAM UEI Number Tax ID Number Business Size Provide information as to what water testing services are provided by your company. Provide how your company invoices for services in the commercial marketplace. Business Size/Type: Service-Disabled Veteran Owned Small Business (SDVOSB), Veteran Owned Small Business (VOSB), 8(a), Hub Zone Small Business, Women Owned Small Business (WOSB), Small Disadvantaged Business (SDB), Small Business, or Large Business. All prospective Contractors are reminded that in accordance with FAR 4.11 they shall be registered in the System for Award Management (SAM) database and shall complete annual Representations and Certifications in SAM prior to any offer. SAM is located at http://www.sam.gov and consolidated the capabilities of CCR/FedReg, ORCA, and EPLS. There is no cost to use SAM. FOR SDVOSB/VOSB ONLY: In order to be eligible, interested parties must be registered in the System for Award Management (SAM) data base at https://sam.gov. For firms claiming SDVOSB/VOSB classification status, they must also be registered and certified through the Department of Veterans Affairs Office of Small & Disadvantaged Business Utilization data base, located at https://veterans.certify.sba.gov/. Please include a copy of your certification with your response. Contractor shall include 3 past contracts for the same or similar services. Contractor shall include at minimum: Name of Company Company POC Company POC phone Company POC email Dollar amount of contract Contract number Period of Performance Description of services provided Contractor shall include any relevant comments about the attachments, if applicable. Contractor shall provide a public price list/contract price list for the services described herein. Contractor shall provide a detailed response to include your firm s ability, capability, and responsibility to deliver the services presented in this Sources Sought Notice. Contractor shall provide if they plan to sub-contract all or part of the work, and to what firm to include the subs duns number and business size. Determination by the Government does not compete with this proposed contract action based on responses to this notice is solely within the discretion of the Government. STATEMENT OF WORK SPS Water Testing Services Part I. Description of Services: The contractor shall provide all the following for testing the water for/within SPS per the ANSI/AAMI ST108:2023 at the Marion, Fort Wayne, and Jackie Walorski VA sites as defined in this Statement of Work (SOW). WORK TO BE PERFORMED: Contractors shall provide all labor, materials, equipment, transportation, lodging and supervision necessary to collect appropriate samples and deliver to a lab meeting requirement for processing of AAMI ST108. Contractors shall calibrate the conductivity/resistivity meter monthly during their testing visit and provide a water analysis report. The contractor will be part of the multidisciplinary team that assists the water working group with resolving out of range water testing, in addition to: Serves as the subject matter expert on water testing per the ST108:2023 Serves as the subject matter expert on corrective actions and to mitigate risks for out-of-range water testing parameters. Completes the monthly, quarterly, and yearly testing per the ST108:2023 and per the VHA water contract/SOW. Completes performance qualification testing per the ST108:2023 and per the VHA contract/SOW. Completes follow up testing as ordered by engineering for out-of-range water parameters per the ST108:2023 and VHA water contract/SOW. Contractor shall provide consultative services as needed such as resolving abnormal water testing results, water system analysis, and mitigation of the tests performed Part II Work Requirements Water Treatment Testing Qualifications: The contractor shall have been in business at least five years providing water treatment testing of water distribution systems similar in design at a medical center. Provide a list of at least five references similar to Department of Veterans Affairs who have utilized the services for water treatment in the last three years. One water treatment specialist who has a bachelor s degree in chemical engineering or the physical sciences from an accredited college or university shall be assigned to this contract. The water treatment specialist must have at least five years successful experience with water treatment programs and shall furnish references from at least three customers who utilize water treatment programs. The contractor must operate (or continuously maintain a contract with) a state of Indiana certified laboratory to perform complete scientific analyses of water chemistry, deposits, metallic materials affected by corrosion and provide recommendations for correction of problems related to the chemical and mechanical water treatment program. A Professional Chemist shall supervise the laboratory. On-Site Services: Provide complete written instructions, supplemented by oral instructions and demonstrations, to SPS personnel for their performance of routine water tests. The instructions cover all aspects of safe chemical handling and safe and accurate testing and methods to suit the SPS operating parameters and water treatment performance requirements. Provide one training session within one week of the start of the contract. Provide one training session annually after the new contract has been awarded. The vendor will provide a handheld resistivity meter as well as pH hardness colorimetric dipsticks to the VA. The vendor shall calibrate the resistivity meter on a monthly basis during their testing visit and provide a calibration certification with this visit as part of the report. The vendor shall provide a detailed operations manual and training to the VA staff for procedures related to VA required testing noted below: AAMI ST108 UTILITY WATER, CRITICAL WATER, AND STEAM TESTING BY VENDOR: Fort Wayne Routine (monthly) POU Testing by Vendor Water Quality Measurement Units Type of Testing Routine Sample Site Utility Routine Sample Site Critical Minimum Frequency of Testing and Testing Range Utility Water Critical Water pH pH pH Meter or Colorimetric dipsticks Medivator Basin x4 Decon sinks x3 Washer x1 Ultrasonic x1 Eye Ultrasonic X1 6.5-9.5 Quarterly 5.0-7.5 Monthly Conductivity uS/cm Conductivity Meter Medivator Basin x4 Decon sinks x3 Washer x1 Ultrasonic x1 Eye UltrasonicX1 <500 Quarterly <10 Monthly Total Alkalinity mg CaCO3/L Colorimetric dipsticks or Alkalinity test kit Medivator Basin x4 Decon sinks x3 Washer x1 Ultrasonic x1 Eye Ultrasonic X1 <400 Quarterly <8 Monthly Total Hardness mg CaCO3/L Determination of ppm as CaCO3/L by colorimetric dipsticks, titration kit, or handheld meter Medivator Basin x4 Decon sinks x3 Washer x1 Ultrasonic x1 Eye Ultrasonic X1 <150 Quarterly <1 Monthly Bacteria CFU/mL Heterotrophic Plate Count (HPC) NA Decon sinks x3 Medivator Basin x4 Washer x1 Ultrasonic x1 Eye Ultrasonic X1 <500 Quarterly <10 Monthly Endotoxin EU/mL LAL Test NA Decon sinks x3 Medivator Basin x4 Washer x1 Ultrasonic x1 Eye Ultrasonic X1 NA NA <10 Monthly Fort Wayne Point of Generation Routine (monthly) Testing by Vendor Water Quality Measurement Units Type of Testing Routine Sample Site Critical Minimum Frequency of Testing and Testing Range Critical Water pH pH pH Meter or Colorimetric dipsticks Loop Supply Loop Return 5.0-7.5 Monthly Conductivity uS/cm Conductivity Meter (in line or measurement of a collected sample) Loop Supply Loop Return <10 Monthly Total Alkalinity mg CaCO3/L Colorimetric dipsticks or Alkalinity test kit Loop Supply Loop Return <8 Monthly Total Hardness mg CaCO3/L Determination of ppm as CaCO3/L by colorimetric dipsticks, titration kit, or handheld meter Loop Supply Loop Return <1 Monthly Bacteria CFU/mL Heterotrophic Plate Count (HPC) Loop Supply Loop Return <10 Monthly Endotoxin EU/mL LAL Test Loop Supply Loop Return <10 Monthly Fort Wayne Performance Qualification Testing (quarterly) Testing by Vendor Water Quality Measurement Units Type of Testing PQ Sample Site Utility PQ Sample Site Critical PQ Sample Site Steam Minimum Frequency of Testing and Testing Range Utility Water Critical Water Steam pH pH pH Meter or Colorimetric dipsticks Decon sinks x4 Medivator Basin x4 Washer x2 Ultrasonic x2 Eye Ultrasonic X2 City Water Water Softener Utility DI After Carbon Filter Medivator 1 Supply Medivator 2 Supply Decon sinks x3 Washer x1 Ultrasonic x1 Eye Ultrasonic X1 Loop Supply Loop Return After RO After DI Sterilizer x2 6.5-9.5 Quarterly 5.0-7.5 Monthly 5.0-9.2 Quarterly Conductivity uS/cm Conductivity Meter Decon sinks x4 Medivator Basin x4 Washer x2 Ultrasonic x2 Eye Ultrasonic X2 City Water Water Softener Utility DI After Carbon Filter Medivator 1 Supply Medivator 2 Supply Decon sinks x3 Washer x1 Ultrasonic x1 Eye Ultrasonic X1 Loop Supply Loop Return After RO After DI Sterilizer x2 <500 Quarterly <10 Monthly <10 Quarterly Total Alkalinity mg CaCO3/L Colorimetric dipsticks or Alkalinity test kit Decon sinks x4 Medivator Basin x4 Washer x2 Ultrasonic x2 Eye Ultrasonic X2 City Water Water Softener Utility DI After Carbon Filter Medivator 1 Supply Medivator 2 Supply Decon sinks x3 Washer x1 Ultrasonic x1 Eye Ultrasonic X1 Loop Supply Loop Return After RO After DI Sterilizer x2 <400 Quarterly <8 Monthly <8 Quarterly Total Hardness mg CaCO3/L Determination of ppm as CaCO3/L by colorimetric dipsticks, titration kit, or handheld meter Decon sinks x4 Medivator Basin x4 Washer x2 Ultrasonic x2 Eye Ultrasonic X2 City Water Water Softener Utility DI After Carbon Filter Medivator 1 Supply Medivator 2 Supply Decon sinks x3 Washer x1 Ultrasonic x1 Eye Ultrasonic X1 Loop Supply Loop Return After RO After DI Sterilizer x2 <150 Quarterly <1 Monthly <1 Quarterly Total Organic Carbon (TOC) mg/L (ppm) NA Decon sinks x3 Washer x1 Ultrasonic x1 Eye Ultrasonic X1 Loop Supply Loop Return After RO After DI NA NA NA <1.0 Quarterly NA NA Aluminum mg/L Decon sinks x4 Medivator Basin x4 Washer x2 Ultrasonic x2 Eye Ultrasonic X2 City Water Water Softener Utility DI After Carbon Filter Medivator 1 Supply Medivator 2 Supply Decon sinks x3 Washer x1 Ultrasonic x1 Eye Ultrasonic X1 Loop Supply Loop Return After RO After DI Sterilizer x2 <0.1 Quarterly <0.1 Quarterly <0.1 Quarterly Chloride mg/L Decon sinks x4 Medivator Basin x4 Washer x2 Ultrasonic x2 Eye Ultrasonic X2 City Water Water Softener Utility DI After Carbon Filter Medivator 1 Supply Medivator 2 Supply Decon sinks x3 Washer x1 Ultrasonic x1 Eye Ultrasonic X1 Loop Supply Loop Return After RO After DI Sterilizer x2 <250 Quarterly <1 Quarterly <1 Quarterly Copper mg/L Decon sinks x4 Medivator Basin x4 Washer x2 Ultrasonic x2 Eye Ultrasonic X2 City Water Water Softener Utility DI After Carbon Filter Medivator 1 Supply Medivator 2 Supply Decon sinks x3 Washer x1 Ultrasonic x1 Eye Ultrasonic X1 Loop Supply Loop Return After RO After DI Sterilizer x2 <0.1 Quarterly <0.1 Quarterly <0.1 Quarterly Iron mg/L Decon sinks x4 Medivator Basin x4 Washer x2 Ultrasonic x2 Eye Ultrasonic X2 City Water Water Softener Utility DI After Carbon Filter Medivator 1 Supply Medivator 2 Supply Decon sinks x3 Washer x1 Ultrasonic x1 Eye Ultrasonic X1 Loop Supply Loop Return After RO After DI Sterilizer x2 <0.1 Quarterly <0.1 Quarterly <0.1 Quarterly Manganese mg/L Decon sinks x4 Medivator Basin x4 Washer x2 Ultrasonic x2 Eye Ultrasonic X2 City Water Water Softener Utility DI After Carbon Filter Medivator 1 Supply Medivator 2 Supply Decon sinks x3 Washer x1 Ultrasonic x1 Eye Ultrasonic X1 Loop Supply Loop Return After RO After DI Sterilizer x2 <0.1 Quarterly <0.1 Quarterly <0.1 Quarterly Nitrate mg/L Decon sinks x4 Medivator Basin x4 Washer x2 Ultrasonic x2 Eye Ultrasonic X2 City Water Water Softener Utility DI After Carbon Filter Medivator 1 Supply Medivator 2 Supply Decon sinks x3 Washer x1 Ultrasonic x1 Eye Ultrasonic X1 Loop Supply Loop Return After RO After DI Sterilizer x2 <10 Quarterly <1 Quarterly <1 Quarterly Phosphate mg/L Decon sinks x4 Medivator Basin x4 Washer x2 Ultrasonic x2 Eye Ultrasonic X2 City Water Water Softener Utility DI After Carbon Filter Medivator 1 Supply Medivator 2 Supply Decon sinks x3 Washer x1 Ultrasonic x1 Eye Ultrasonic X1 Loop Supply Loop Return After RO After DI Sterilizer x2 <5 Quarterly <1 Quarterly <1 Quarterly Silicate mg/L Decon sinks x4 Medivator Basin x4 Washer x2 Ultrasonic x2 Eye Ultrasonic X2 City Water Water Softener Utility DI After Carbon Filter Medivator 1 Supply Medivator 2 Supply Decon sinks x3 Washer x1 Ultrasonic x1 Eye Ultrasonic X1 Loop Supply Loop Return After RO After DI Sterilizer x2 <50 Quarterly <1 Quarterly <1 Quarterly Sulfate mg/L Decon sinks x4 Medivator Basin x4 Washer x2 Ultrasonic x2 Eye Ultrasonic X2 City Water Water Softener Utility DI After Carbon Filter Medivator 1 Supply Medivator 2 Supply Decon sinks x3 Washer x1 Ultrasonic x1 Eye Ultrasonic X1 Loop Supply Loop Return After RO After DI Sterilizer x2 <150 Quarterly <1 Quarterly <1 Quarterly Zinc mg/L Decon sinks x4 Medivator Basin x4 Washer x2 Ultrasonic x2 Eye Ultrasonic X2 City Water Water Softener Utility DI After Carbon Filter Medivator 1 Supply Medivator 2 Supply Decon sinks x3 Washer x1 Ultrasonic x1 Eye Ultrasonic X1 Loop Supply Loop Return After RO After DI Sterilizer x2 <0.1 Quarterly <0.1 Quarterly <0.1 Quarterly Bacteria CFU/mL Heterotrophic Plate Count (HPC) Decon sinks x4 Washer x2 Ultrasonic x2 Eye Ultrasonic X2 City Water Water Softener Utility DI After Carbon Filter Medivator 1 Supply Medivator 2 Supply Decon sinks x3 Medivator basin x4 Washer x1 Ultrasonic x1 Eye Ultrasonic X1 Loop Supply Loop Return After RO After DI NA <500 Quarterly <10 Monthly NA NA Endotoxin EU/mL LAL Test NA Decon sinks x3 Medivator basin x4 Washer x1 Ultrasonic x1 Eye Ultrasonic X1 Loop Supply Loop Return After RO After DI NA NA NA <10 Monthly NA NA Marion Routine (monthly) POU Testing by Vendor Water Quality Measurement Units Type of Testing Routine Sample Site Critical Minimum Frequency of Testing and Testing Range Critical Water pH pH pH Meter or Colorimetric dipsticks Decon sinks x1 Washer x1 5.0-7.5 Monthly Conductivity uS/cm Conductivity Meter Decon sinks x1 Washer x1 <10 Monthly Total Alkalinity mg CaCO3/L Colorimetric dipsticks or Alkalinity test kit Decon sinks x1 Washer x1 <8 Monthly Total Hardness mg CaCO3/L Determination of ppm as CaCO3/L by colorimetric dipsticks, titration kit, or handheld meter Decon sinks x1 Washer x1 <1 Monthly Bacteria CFU/mL Heterotrophic Plate Count (HPC) Decon sinks x1 Washer x1 <10 Monthly Endotoxin EU/mL LAL Test Decon sinks x1 Washer x1 <10 Monthly Marion Point of Generation Routine (monthly) Testing by Vendor Water Quality Measurement Units Type of Testing Routine Sample Site Critical Minimum Frequency of Testing and Testing Range Critical Water pH pH pH Meter or Colorimetric dipsticks Supply 5.0-7.5 Monthly Conductivity uS/cm Conductivity Meter (in line or measurement of a collected sample) Supply <10 Monthly Total Alkalinity mg CaCO3/L Colorimetric dipsticks or Alkalinity test kit Supply <8 Monthly Total Hardness mg CaCO3/L Determination of ppm as CaCO3/L by colorimetric dipsticks, titration kit, or handheld meter Supply <1 Monthly Bacteria CFU/mL Heterotrophic Plate Count (HPC) Supply <10 Monthly Endotoxin EU/mL LAL Test Supply <10 Monthly Marion Performance Qualification Testing (quarterly) Testing by Vendor Water Quality Measurement Units Type of Testing PQ Sample Site Utility PQ Sample Site Critical PQ Sample Site Steam Minimum Frequency of Testing and Testing Range Utility Water Critical Water Steam pH pH pH Meter or Colorimetric dipsticks Decon sinks x2 Washer x2 Ultrasonic x2 City Water Water Softener Utility DI After Carbon Filter Decon sinks x1 Washer x1 Supply After RO After DI Sterilizer x2 6.5-9.5 Quarterly 5.0-7.5 Monthly 5.0-9.2 Quarterly Conductivity uS/cm Conductivity Meter Decon sinks x2 Washer x2 Ultrasonic x2 City Water Water Softener Utility DI After Carbon Filter Decon sinks x1 Washer x1 Supply After RO After DI Sterilizer x2 <500 Quarterly <10 Monthly <10 Quarterly Total Alkalinity mg CaCO3/L Colorimetric dipsticks or Alkalinity test kit Decon sinks x2 Washer x2 Ultrasonic x2 City Water Water Softener Utility DI After Carbon Filter Decon sinks x1 Washer x1 Supply After RO After DI Sterilizer x2 <400 Quarterly <8 Monthly <8 Quarterly Total Hardness mg CaCO3/L Determination of ppm as CaCO3/L by colorimetric dipsticks, titration kit, or handheld meter Decon sinks x2 Washer x2 Ultrasonic x2 City Water Water Softener Utility DI After Carbon Filter Decon sinks x1 Washer x1 Supply After RO After DI Sterilizer x2 <150 Quarterly <1 Monthly <1 Quarterly Total Organic Carbon (TOC) mg/L (ppm) NA Decon sinks x1 Washer x1 Supply After RO After DI NA NA NA <1.0 Quarterly NA NA Aluminum mg/L Decon sinks x2 Washer x2 Ultrasonic x2 City Water Water Softener Utility DI After Carbon Filter Decon sinks x1 Washer x1 Supply After RO After DI Sterilizer x2 <0.1 Quarterly <0.1 Quarterly <0.1 Quarterly Chloride mg/L Decon sinks x2 Washer x2 Ultrasonic x2 City Water Water Softener Utility DI After Carbon Filter Decon sinks x1 Washer x1 Supply After RO After DI Sterilizer x2 <250 Quarterly <1 Quarterly <1 Quarterly Copper mg/L Decon sinks x2 Washer x2 Ultrasonic x2 City Water Water Softener Utility DI After Carbon Filter Decon sinks x1 Washer x1 Supply After RO After DI Sterilizer x2 <0.1 Quarterly <0.1 Quarterly <0.1 Quarterly Iron mg/L Decon sinks x2 Washer x2 Ultrasonic x2 City Water Water Softener Utility DI After Carbon Filter Decon sinks x1 Washer x1 Supply After RO After DI Sterilizer x2 <0.1 Quarterly <0.1 Quarterly <0.1 Quarterly Manganese mg/L Decon sinks x2 Washer x2 Ultrasonic x2 City Water Water Softener Utility DI After Carbon Filter Decon sinks x1 Washer x1 Supply After RO After DI Sterilizer x2 <0.1 Quarterly <0.1 Quarterly <0.1 Quarterly Nitrate mg/L Decon sinks x2 Washer x2 Ultrasonic x2 City Water Water Softener Utility DI After Carbon Filter Decon sinks x1 Washer x1 Supply After RO After DI Sterilizer x2 <10 Quarterly <1 Quarterly <1 Quarterly Phosphate mg/L Decon sinks x2 Washer x2 Ultrasonic x2 City Water Water Softener Utility DI After Carbon Filter Decon sinks x1 Washer x1 Supply After RO After DI Sterilizer x2 <5 Quarterly <1 Quarterly <1 Quarterly Silicate mg/L Decon sinks x2 Washer x2 Ultrasonic x2 City Water Water Softener Utility DI After Carbon Filter Decon sinks x1 Washer x1 Supply After RO After DI Sterilizer x2 <50 Quarterly <1 Quarterly <1 Quarterly Sulfate mg/L Decon sinks x2 Washer x2 Ultrasonic x2 City Water Water Softener Utility DI After Carbon Filter Decon sinks x1 Washer x1 Supply After RO After DI Sterilizer x2 <150 Quarterly <1 Quarterly <1 Quarterly Zinc mg/L Decon sinks x2 Washer x2 Ultrasonic x2 City Water Water Softener Utility DI After Carbon Filter Decon sinks x1 Washer x1 Supply After RO After DI Sterilizer x2 <0.1 Quarterly <0.1 Quarterly <0.1 Quarterly Bacteria CFU/mL Heterotrophic Plate Count (HPC) Decon sinks x2 Washer x2 Ultrasonic x2 City Water Water Softener Utility DI After Carbon Filter Decon sinks x1 Washer x1 Supply After RO After DI NA <500 Quarterly <10 Monthly NA NA Endotoxin EU/mL LAL Test NA Decon sinks x1 Washer x1 Supply After RO After DI NA NA NA <10 Monthly NA NA JWC Performance Qualification Testing (quarterly) Testing by Vendor Water Quality Measurement Units Type of Testing PQ Sample Site Utility PQ Sample Site Critical Minimum Frequency of Testing and Testing Range Utility Water Critical Water pH pH pH Meter or Colorimetric dipsticks Decon sink x2 Medivator Basin x4 Water Softener City Water Medivator 30 Supply Medivator 31 Supply NA 6.5-9.5 Quarterly 5.0-7.5 Monthly Conductivity uS/cm Conductivity Meter Decon sink x2 Medivator Basin x4 Water Softener City Water Medivator 30 Supply Medivator 31 Supply NA <500 Quarterly <10 Monthly Total Alkalinity mg CaCO3/L Colorimetric dipsticks or Alkalinity test kit Decon sink x2 Medivator Basin x4 Water Softener City Water NA <400 Quarterly <8 Monthly Total Hardness mg CaCO3/L Determination of ppm as CaCO3/L by colorimetric dipsticks, titration kit, or handheld meter Decon sink x2 Medivator Basin x4 Water Softener City Water NA <150 Quarterly <1 Monthly Total Organic Carbon (TOC) mg/L (ppm) NA NA NA NA <1.0 Quarterly Aluminum mg/L Decon sink x2 Medivator Basin x4 Water Softener City Water Medivator 30 Supply Medivator 31 Supply NA <0.1 Quarterly <0.1 Quarterly Chloride mg/L Decon sink x2 Medivator Basin x4 Water Softener City Water Medivator 30 Supply Medivator 31 Supply NA <250 Quarterly <1 Quarterly Copper mg/L Decon sink x2 Medivator Basin x4 Water Softener City Water Medivator 30 Supply Medivator 31 Supply NA <0.1 Quarterly <0.1 Quarterly Iron mg/L Decon sink x2 Medivator Basin x4 Water Softener City Water Medivator 30 Supply Medivator 31 Supply NA <0.1 Quarterly <0.1 Quarterly Manganese mg/L Decon sink x2 Medivator Basin x4 Water Softener City Water Medivator 30 Supply Medivator 31 Supply NA <0.1 Quarterly <0.1 Quarterly Nitrate mg/L Decon sink x2 Medivator Basin x4 Water Softener City Water Medivator 30 Supply Medivator 31 Supply NA <10 Quarterly <1 Quarterly Phosphate mg/L Decon sink x2 Medivator Basin x4 Water Softener City Water Medivator 30 Supply Medivator 31 Supply NA <5 Quarterly <1 Quarterly Silicate mg/L Decon sink x2 Medivator Basin x4 Water Softener City Water Medivator 30 Supply Medivator 31 Supply NA <50 Quarterly <1 Quarterly Sulfate mg/L Decon sink x2 Medivator Basin x4 Water Softener City Water Medivator 30 Supply Medivator 31 Supply NA <150 Quarterly <1 Quarterly Zinc mg/L Decon sink x2 Medivator Basin x4 Water Softener City Water Medivator 30 Supply Medivator 31 Supply NA <0.1 Quarterly <0.1 Quarterly Bacteria CFU/mL Heterotrophic Plate Count (HPC) Decon sink x2 Water Softener City Water Medivator 30 Supply Medivator 31 Supply Medivator Basin x4 <500 Quarterly <10 Monthly Endotoxin EU/mL LAL Test NA Medivator Basin x4 NA NA <10 Monthly JWC Routine (monthly) POU Testing by Vendor Water Quality Measurement Units Type of Testing Routine Sample Site Utility Routine Sample Site Critical Minimum Frequency of Testing and Testing Range Utility Water Critical Water pH pH pH Meter or Colorimetric dipsticks Medivator Basin x4 NA 6.5-9.5 Quarterly 5.0-7.5 Monthly Conductivity uS/cm Conductivity Meter Medivator Basin x4 NA <500 Quarterly <10 Monthly Total Alkalinity mg CaCO3/L Colorimetric dipsticks or Alkalinity test kit Medivator Basin x4 NA <400 Quarterly <8 Monthly Total Hardness mg CaCO3/L Determination of ppm as CaCO3/L by colorimetric dipsticks, titration kit, or handheld meter Medivator Basin x4 NA <150 Quarterly <1 Monthly Bacteria CFU/mL Heterotrophic Plate Count (HPC) NA Medivator Basin x4 <500 Quarterly <10 Monthly Endotoxin EU/mL LAL Test NA Medivator Basin x4 NA NA <10 Monthly Part III Supporting information: All work to be performed during the normal business hours of 7:00a 4:30p, Monday through Friday, excluding National Holidays. excluding federal holidays. Federal holidays are New Year's Day, Martin Luther King Day, President's Day, Memorial Day, Juneteenth, Independence Day, Labor Day, Columbus Day, Veterans Day, Thanksgiving Day, Christmas, and any other day specifically declared by the President of the United States to be a national holiday. Security: The C&A requirements do not apply, and a Security Accreditation Package is not required. Place of Performance: VA Northern Indiana Health Care System (Marion) 1700 E 38th St. Marion, Indiana 46953 VA Northern Indiana Health Care System (Fort Wayne) 2121 Lake Ave. Fort Wayne, Indiana 46805 Jackie Walorski VA Clinic (St. Joseph County VA Health Care Center) 1540 Trinity Place, Mishawaka, IN 46545. Submittals are required for all Products and Services: Provide three hard copies of all specifications of all products: name, ingredients, control range, test procedures, physical state (liquid, powder, etc.), container size, method of delivery, compatibility with present materials being used, catalog data, MSDS sheets

From Sources Sought posted on Apr 07, 2026

THIS IS A SOURCES SOUGHT ANNOUNCEMENT FOR INFORMATION ONLY. THIS IS NOT A SOLICITATION FOR PROPOSALS AND NO CONTRACT WILL BE AWARDED FROM THIS ANNOUNCEMENT. The purpose of this notice is to conduct market research and obtain information from qualified businesses with special interest in seeking: VA certified Service-Disabled Veteran owned Small Business (SDVOSB), VA certified Veteran Owned Small Business (VOSB) and Small Business (SB) concerns. No solicitation is being issued at this time. All information submitted in response to this announcement is voluntary; the Government will not pay for information requested nor will it compensate any respondent for any cost incurred in developing information provided to the Government. The Department of Veteran Affairs, Northern Indiana Health Care System (NIHCS) has a requirement for Water Testing and Reagents for the sterile processing system (SPS) at the Marion, Fort Wayne, and Jackie Walorski VA sites. The appropriate NAICS Code 541380, Testing Laboratories, Size Standard $16.5 Million Responses: Please submit your response in accordance with the following instructions: Responses shall be no more than 10 pages in length. Responses are due by 4/22/2026 at 15:00 PM EST. Responses shall be submitted via email to eric.sweatt@va.gov. Emails cannot exceed 5mb Subject line of the Email shall include this Sources Sought Notice Number Firm Name NIHCS Water Testing and Reagents for the SPS Services. If your response contains proprietary information you will place Proprietary Information in front of the Sources Sought Notice Number. No marketing materials are allowed as part of this Sources Sought Notice. The Government will not review any other information or attachments included in your submission that is not listed herein or exceeds the 10-page limitation. Contractors Federal Supply Schedule Contract that carries the desired services If you do not have a Federal Supply Schedule contract, you shall state open market Provide the Schedule Provide expiration date of your Contract Provide your GSA/FSS/SAC Contract Number Provide the SIN for water testing and reagents for SPS services If any of the items are not on your GSA/FSS contract, you will mark which items are open market. Contractor Point of Contact to include: Name Title Phone Email Company Information to include: Name Address SAM UEI Number Tax ID Number Business Size Provide information as to what water testing services are provided by your company. Provide how your company invoices for services in the commercial marketplace. Business Size/Type: Service-Disabled Veteran Owned Small Business (SDVOSB), Veteran Owned Small Business (VOSB), 8(a), Hub Zone Small Business, Women Owned Small Business (WOSB), Small Disadvantaged Business (SDB), Small Business, or Large Business. All prospective Contractors are reminded that in accordance with FAR 4.11 they shall be registered in the System for Award Management (SAM) database and shall complete annual Representations and Certifications in SAM prior to any offer. SAM is located at http://www.sam.gov and consolidated the capabilities of CCR/FedReg, ORCA, and EPLS. There is no cost to use SAM. FOR SDVOSB/VOSB ONLY: In order to be eligible, interested parties must be registered in the System for Award Management (SAM) data base at https://sam.gov. For firms claiming SDVOSB/VOSB classification status, they must also be registered and certified through the Department of Veterans Affairs Office of Small & Disadvantaged Business Utilization data base, located at https://veterans.certify.sba.gov/. Please include a copy of your certification with your response. Contractor shall include 3 past contracts for the same or similar services. Contractor shall include at minimum: Name of Company Company POC Company POC phone Company POC email Dollar amount of contract Contract number Period of Performance Description of services provided Contractor shall include any relevant comments about the attachments, if applicable. Contractor shall provide a public price list/contract price list for the services described herein. Contractor shall provide a detailed response to include your firm s ability, capability, and responsibility to deliver the services presented in this Sources Sought Notice. Contractor shall provide if they plan to sub-contract all or part of the work, and to what firm to include the subs duns number and business size. Determination by the Government does not compete with this proposed contract action based on responses to this notice is solely within the discretion of the Government. STATEMENT OF WORK SPS Water Testing Services Part I. Description of Services: The contractor shall provide all the following for testing the water for/within SPS per the ANSI/AAMI ST108:2023 at the Marion, Fort Wayne, and Jackie Walorski VA sites as defined in this Statement of Work (SOW). WORK TO BE PERFORMED: Contractors shall provide all labor, materials, equipment, transportation, lodging and supervision necessary to collect appropriate samples and deliver to a lab meeting requirement for processing of AAMI ST108. Contractors shall calibrate the conductivity/resistivity meter monthly during their testing visit and provide a water analysis report. The contractor will be part of the multidisciplinary team that assists the water working group with resolving out of range water testing, in addition to: Serves as the subject matter expert on water testing per the ST108:2023 Serves as the subject matter expert on corrective actions and to mitigate risks for out-of-range water testing parameters. Completes the monthly, quarterly, and yearly testing per the ST108:2023 and per the VHA water contract/SOW. Completes performance qualification testing per the ST108:2023 and per the VHA contract/SOW. Completes follow up testing as ordered by engineering for out-of-range water parameters per the ST108:2023 and VHA water contract/SOW. Contractor shall provide consultative services as needed such as resolving abnormal water testing results, water system analysis, and mitigation of the tests performed Part II Work Requirements Water Treatment Testing Qualifications: The contractor shall have been in business at least five years providing water treatment testing of water distribution systems similar in design at a medical center. Provide a list of at least five references similar to Department of Veterans Affairs who have utilized the services for water treatment in the last three years. One water treatment specialist who has a bachelor s degree in chemical engineering or the physical sciences from an accredited college or university shall be assigned to this contract. The water treatment specialist must have at least five years successful experience with water treatment programs and shall furnish references from at least three customers who utilize water treatment programs. The contractor must operate (or continuously maintain a contract with) a state of Indiana certified laboratory to perform complete scientific analyses of water chemistry, deposits, metallic materials affected by corrosion and provide recommendations for correction of problems related to the chemical and mechanical water treatment program. A Professional Chemist shall supervise the laboratory. On-Site Services: Provide complete written instructions, supplemented by oral instructions and demonstrations, to SPS personnel for their performance of routine water tests. The instructions cover all aspects of safe chemical handling and safe and accurate testing and methods to suit the SPS operating parameters and water treatment performance requirements. Provide one training session within one week of the start of the contract. Provide one training session annually after the new contract has been awarded. The vendor will provide a handheld resistivity meter as well as pH hardness colorimetric dipsticks to the VA. The vendor shall calibrate the resistivity meter on a monthly basis during their testing visit and provide a calibration certification with this visit as part of the report. The vendor shall provide a detailed operations manual and training to the VA staff for procedures related to VA required testing noted below: AAMI ST108 UTILITY WATER, CRITICAL WATER, AND STEAM TESTING BY VENDOR: Fort Wayne Routine (monthly) POU Testing by Vendor Water Quality Measurement Units Type of Testing Routine Sample Site Utility Routine Sample Site Critical Minimum Frequency of Testing and Testing Range Utility Water Critical Water pH pH pH Meter or Colorimetric dipsticks Medivator Basin x4 Decon sinks x3 Washer x1 Ultrasonic x1 Eye Ultrasonic X1 6.5-9.5 Quarterly 5.0-7.5 Monthly Conductivity uS/cm Conductivity Meter Medivator Basin x4 Decon sinks x3 Washer x1 Ultrasonic x1 Eye UltrasonicX1 <500 Quarterly <10 Monthly Total Alkalinity mg CaCO3/L Colorimetric dipsticks or Alkalinity test kit Medivator Basin x4 Decon sinks x3 Washer x1 Ultrasonic x1 Eye Ultrasonic X1 <400 Quarterly <8 Monthly Total Hardness mg CaCO3/L Determination of ppm as CaCO3/L by colorimetric dipsticks, titration kit, or handheld meter Medivator Basin x4 Decon sinks x3 Washer x1 Ultrasonic x1 Eye Ultrasonic X1 <150 Quarterly <1 Monthly Bacteria CFU/mL Heterotrophic Plate Count (HPC) NA Decon sinks x3 Medivator Basin x4 Washer x1 Ultrasonic x1 Eye Ultrasonic X1 <500 Quarterly <10 Monthly Endotoxin EU/mL LAL Test NA Decon sinks x3 Medivator Basin x4 Washer x1 Ultrasonic x1 Eye Ultrasonic X1 NA NA <10 Monthly Fort Wayne Point of Generation Routine (monthly) Testing by Vendor Water Quality Measurement Units Type of Testing Routine Sample Site Critical Minimum Frequency of Testing and Testing Range Critical Water pH pH pH Meter or Colorimetric dipsticks Loop Supply Loop Return 5.0-7.5 Monthly Conductivity uS/cm Conductivity Meter (in line or measurement of a collected sample) Loop Supply Loop Return <10 Monthly Total Alkalinity mg CaCO3/L Colorimetric dipsticks or Alkalinity test kit Loop Supply Loop Return <8 Monthly Total Hardness mg CaCO3/L Determination of ppm as CaCO3/L by colorimetric dipsticks, titration kit, or handheld meter Loop Supply Loop Return <1 Monthly Bacteria CFU/mL Heterotrophic Plate Count (HPC) Loop Supply Loop Return <10 Monthly Endotoxin EU/mL LAL Test Loop Supply Loop Return <10 Monthly Fort Wayne Performance Qualification Testing (quarterly) Testing by Vendor Water Quality Measurement Units Type of Testing PQ Sample Site Utility PQ Sample Site Critical PQ Sample Site Steam Minimum Frequency of Testing and Testing Range Utility Water Critical Water Steam pH pH pH Meter or Colorimetric dipsticks Decon sinks x4 Medivator Basin x4 Washer x2 Ultrasonic x2 Eye Ultrasonic X2 City Water Water Softener Utility DI After Carbon Filter Medivator 1 Supply Medivator 2 Supply Decon sinks x3 Washer x1 Ultrasonic x1 Eye Ultrasonic X1 Loop Supply Loop Return After RO After DI Sterilizer x2 6.5-9.5 Quarterly 5.0-7.5 Monthly 5.0-9.2 Quarterly Conductivity uS/cm Conductivity Meter Decon sinks x4 Medivator Basin x4 Washer x2 Ultrasonic x2 Eye Ultrasonic X2 City Water Water Softener Utility DI After Carbon Filter Medivator 1 Supply Medivator 2 Supply Decon sinks x3 Washer x1 Ultrasonic x1 Eye Ultrasonic X1 Loop Supply Loop Return After RO After DI Sterilizer x2 <500 Quarterly <10 Monthly <10 Quarterly Total Alkalinity mg CaCO3/L Colorimetric dipsticks or Alkalinity test kit Decon sinks x4 Medivator Basin x4 Washer x2 Ultrasonic x2 Eye Ultrasonic X2 City Water Water Softener Utility DI After Carbon Filter Medivator 1 Supply Medivator 2 Supply Decon sinks x3 Washer x1 Ultrasonic x1 Eye Ultrasonic X1 Loop Supply Loop Return After RO After DI Sterilizer x2 <400 Quarterly <8 Monthly <8 Quarterly Total Hardness mg CaCO3/L Determination of ppm as CaCO3/L by colorimetric dipsticks, titration kit, or handheld meter Decon sinks x4 Medivator Basin x4 Washer x2 Ultrasonic x2 Eye Ultrasonic X2 City Water Water Softener Utility DI After Carbon Filter Medivator 1 Supply Medivator 2 Supply Decon sinks x3 Washer x1 Ultrasonic x1 Eye Ultrasonic X1 Loop Supply Loop Return After RO After DI Sterilizer x2 <150 Quarterly <1 Monthly <1 Quarterly Total Organic Carbon (TOC) mg/L (ppm) NA Decon sinks x3 Washer x1 Ultrasonic x1 Eye Ultrasonic X1 Loop Supply Loop Return After RO After DI NA NA NA <1.0 Quarterly NA NA Aluminum mg/L Decon sinks x4 Medivator Basin x4 Washer x2 Ultrasonic x2 Eye Ultrasonic X2 City Water Water Softener Utility DI After Carbon Filter Medivator 1 Supply Medivator 2 Supply Decon sinks x3 Washer x1 Ultrasonic x1 Eye Ultrasonic X1 Loop Supply Loop Return After RO After DI Sterilizer x2 <0.1 Quarterly <0.1 Quarterly <0.1 Quarterly Chloride mg/L Decon sinks x4 Medivator Basin x4 Washer x2 Ultrasonic x2 Eye Ultrasonic X2 City Water Water Softener Utility DI After Carbon Filter Medivator 1 Supply Medivator 2 Supply Decon sinks x3 Washer x1 Ultrasonic x1 Eye Ultrasonic X1 Loop Supply Loop Return After RO After DI Sterilizer x2 <250 Quarterly <1 Quarterly <1 Quarterly Copper mg/L Decon sinks x4 Medivator Basin x4 Washer x2 Ultrasonic x2 Eye Ultrasonic X2 City Water Water Softener Utility DI After Carbon Filter Medivator 1 Supply Medivator 2 Supply Decon sinks x3 Washer x1 Ultrasonic x1 Eye Ultrasonic X1 Loop Supply Loop Return After RO After DI Sterilizer x2 <0.1 Quarterly <0.1 Quarterly <0.1 Quarterly Iron mg/L Decon sinks x4 Medivator Basin x4 Washer x2 Ultrasonic x2 Eye Ultrasonic X2 City Water Water Softener Utility DI After Carbon Filter Medivator 1 Supply Medivator 2 Supply Decon sinks x3 Washer x1 Ultrasonic x1 Eye Ultrasonic X1 Loop Supply Loop Return After RO After DI Sterilizer x2 <0.1 Quarterly <0.1 Quarterly <0.1 Quarterly Manganese mg/L Decon sinks x4 Medivator Basin x4 Washer x2 Ultrasonic x2 Eye Ultrasonic X2 City Water Water Softener Utility DI After Carbon Filter Medivator 1 Supply Medivator 2 Supply Decon sinks x3 Washer x1 Ultrasonic x1 Eye Ultrasonic X1 Loop Supply Loop Return After RO After DI Sterilizer x2 <0.1 Quarterly <0.1 Quarterly <0.1 Quarterly Nitrate mg/L Decon sinks x4 Medivator Basin x4 Washer x2 Ultrasonic x2 Eye Ultrasonic X2 City Water Water Softener Utility DI After Carbon Filter Medivator 1 Supply Medivator 2 Supply Decon sinks x3 Washer x1 Ultrasonic x1 Eye Ultrasonic X1 Loop Supply Loop Return After RO After DI Sterilizer x2 <10 Quarterly <1 Quarterly <1 Quarterly Phosphate mg/L Decon sinks x4 Medivator Basin x4 Washer x2 Ultrasonic x2 Eye Ultrasonic X2 City Water Water Softener Utility DI After Carbon Filter Medivator 1 Supply Medivator 2 Supply Decon sinks x3 Washer x1 Ultrasonic x1 Eye Ultrasonic X1 Loop Supply Loop Return After RO After DI Sterilizer x2 <5 Quarterly <1 Quarterly <1 Quarterly Silicate mg/L Decon sinks x4 Medivator Basin x4 Washer x2 Ultrasonic x2 Eye Ultrasonic X2 City Water Water Softener Utility DI After Carbon Filter Medivator 1 Supply Medivator 2 Supply Decon sinks x3 Washer x1 Ultrasonic x1 Eye Ultrasonic X1 Loop Supply Loop Return After RO After DI Sterilizer x2 <50 Quarterly <1 Quarterly <1 Quarterly Sulfate mg/L Decon sinks x4 Medivator Basin x4 Washer x2 Ultrasonic x2 Eye Ultrasonic X2 City Water Water Softener Utility DI After Carbon Filter Medivator 1 Supply Medivator 2 Supply Decon sinks x3 Washer x1 Ultrasonic x1 Eye Ultrasonic X1 Loop Supply Loop Return After RO After DI Sterilizer x2 <150 Quarterly <1 Quarterly <1 Quarterly Zinc mg/L Decon sinks x4 Medivator Basin x4 Washer x2 Ultrasonic x2 Eye Ultrasonic X2 City Water Water Softener Utility DI After Carbon Filter Medivator 1 Supply Medivator 2 Supply Decon sinks x3 Washer x1 Ultrasonic x1 Eye Ultrasonic X1 Loop Supply Loop Return After RO After DI Sterilizer x2 <0.1 Quarterly <0.1 Quarterly <0.1 Quarterly Bacteria CFU/mL Heterotrophic Plate Count (HPC) Decon sinks x4 Washer x2 Ultrasonic x2 Eye Ultrasonic X2 City Water Water Softener Utility DI After Carbon Filter Medivator 1 Supply Medivator 2 Supply Decon sinks x3 Medivator basin x4 Washer x1 Ultrasonic x1 Eye Ultrasonic X1 Loop Supply Loop Return After RO After DI NA <500 Quarterly <10 Monthly NA NA Endotoxin EU/mL LAL Test NA Decon sinks x3 Medivator basin x4 Washer x1 Ultrasonic x1 Eye Ultrasonic X1 Loop Supply Loop Return After RO After DI NA NA NA <10 Monthly NA NA Marion Routine (monthly) POU Testing by Vendor Water Quality Measurement Units Type of Testing Routine Sample Site Critical Minimum Frequency of Testing and Testing Range Critical Water pH pH pH Meter or Colorimetric dipsticks Decon sinks x1 Washer x1 5.0-7.5 Monthly Conductivity uS/cm Conductivity Meter Decon sinks x1 Washer x1 <10 Monthly Total Alkalinity mg CaCO3/L Colorimetric dipsticks or Alkalinity test kit Decon sinks x1 Washer x1 <8 Monthly Total Hardness mg CaCO3/L Determination of ppm as CaCO3/L by colorimetric dipsticks, titration kit, or handheld meter Decon sinks x1 Washer x1 <1 Monthly Bacteria CFU/mL Heterotrophic Plate Count (HPC) Decon sinks x1 Washer x1 <10 Monthly Endotoxin EU/mL LAL Test Decon sinks x1 Washer x1 <10 Monthly Marion Point of Generation Routine (monthly) Testing by Vendor Water Quality Measurement Units Type of Testing Routine Sample Site Critical Minimum Frequency of Testing and Testing Range Critical Water pH pH pH Meter or Colorimetric dipsticks Supply 5.0-7.5 Monthly Conductivity uS/cm Conductivity Meter (in line or measurement of a collected sample) Supply <10 Monthly Total Alkalinity mg CaCO3/L Colorimetric dipsticks or Alkalinity test kit Supply <8 Monthly Total Hardness mg CaCO3/L Determination of ppm as CaCO3/L by colorimetric dipsticks, titration kit, or handheld meter Supply <1 Monthly Bacteria CFU/mL Heterotrophic Plate Count (HPC) Supply <10 Monthly Endotoxin EU/mL LAL Test Supply <10 Monthly Marion Performance Qualification Testing (quarterly) Testing by Vendor Water Quality Measurement Units Type of Testing PQ Sample Site Utility PQ Sample Site Critical PQ Sample Site Steam Minimum Frequency of Testing and Testing Range Utility Water Critical Water Steam pH pH pH Meter or Colorimetric dipsticks Decon sinks x2 Washer x2 Ultrasonic x2 City Water Water Softener Utility DI After Carbon Filter Decon sinks x1 Washer x1 Supply After RO After DI Sterilizer x2 6.5-9.5 Quarterly 5.0-7.5 Monthly 5.0-9.2 Quarterly Conductivity uS/cm Conductivity Meter Decon sinks x2 Washer x2 Ultrasonic x2 City Water Water Softener Utility DI After Carbon Filter Decon sinks x1 Washer x1 Supply After RO After DI Sterilizer x2 <500 Quarterly <10 Monthly <10 Quarterly Total Alkalinity mg CaCO3/L Colorimetric dipsticks or Alkalinity test kit Decon sinks x2 Washer x2 Ultrasonic x2 City Water Water Softener Utility DI After Carbon Filter Decon sinks x1 Washer x1 Supply After RO After DI Sterilizer x2 <400 Quarterly <8 Monthly <8 Quarterly Total Hardness mg CaCO3/L Determination of ppm as CaCO3/L by colorimetric dipsticks, titration kit, or handheld meter Decon sinks x2 Washer x2 Ultrasonic x2 City Water Water Softener Utility DI After Carbon Filter Decon sinks x1 Washer x1 Supply After RO After DI Sterilizer x2 <150 Quarterly <1 Monthly <1 Quarterly Total Organic Carbon (TOC) mg/L (ppm) NA Decon sinks x1 Washer x1 Supply After RO After DI NA NA NA <1.0 Quarterly NA NA Aluminum mg/L Decon sinks x2 Washer x2 Ultrasonic x2 City Water Water Softener Utility DI After Carbon Filter Decon sinks x1 Washer x1 Supply After RO After DI Sterilizer x2 <0.1 Quarterly <0.1 Quarterly <0.1 Quarterly Chloride mg/L Decon sinks x2 Washer x2 Ultrasonic x2 City Water Water Softener Utility DI After Carbon Filter Decon sinks x1 Washer x1 Supply After RO After DI Sterilizer x2 <250 Quarterly <1 Quarterly <1 Quarterly Copper mg/L Decon sinks x2 Washer x2 Ultrasonic x2 City Water Water Softener Utility DI After Carbon Filter Decon sinks x1 Washer x1 Supply After RO After DI Sterilizer x2 <0.1 Quarterly <0.1 Quarterly <0.1 Quarterly Iron mg/L Decon sinks x2 Washer x2 Ultrasonic x2 City Water Water Softener Utility DI After Carbon Filter Decon sinks x1 Washer x1 Supply After RO After DI Sterilizer x2 <0.1 Quarterly <0.1 Quarterly <0.1 Quarterly Manganese mg/L Decon sinks x2 Washer x2 Ultrasonic x2 City Water Water Softener Utility DI After Carbon Filter Decon sinks x1 Washer x1 Supply After RO After DI Sterilizer x2 <0.1 Quarterly <0.1 Quarterly <0.1 Quarterly Nitrate mg/L Decon sinks x2 Washer x2 Ultrasonic x2 City Water Water Softener Utility DI After Carbon Filter Decon sinks x1 Washer x1 Supply After RO After DI Sterilizer x2 <10 Quarterly <1 Quarterly <1 Quarterly Phosphate mg/L Decon sinks x2 Washer x2 Ultrasonic x2 City Water Water Softener Utility DI After Carbon Filter Decon sinks x1 Washer x1 Supply After RO After DI Sterilizer x2 <5 Quarterly <1 Quarterly <1 Quarterly Silicate mg/L Decon sinks x2 Washer x2 Ultrasonic x2 City Water Water Softener Utility DI After Carbon Filter Decon sinks x1 Washer x1 Supply After RO After DI Sterilizer x2 <50 Quarterly <1 Quarterly <1 Quarterly Sulfate mg/L Decon sinks x2 Washer x2 Ultrasonic x2 City Water Water Softener Utility DI After Carbon Filter Decon sinks x1 Washer x1 Supply After RO After DI Sterilizer x2 <150 Quarterly <1 Quarterly <1 Quarterly Zinc mg/L Decon sinks x2 Washer x2 Ultrasonic x2 City Water Water Softener Utility DI After Carbon Filter Decon sinks x1 Washer x1 Supply After RO After DI Sterilizer x2 <0.1 Quarterly <0.1 Quarterly <0.1 Quarterly Bacteria CFU/mL Heterotrophic Plate Count (HPC) Decon sinks x2 Washer x2 Ultrasonic x2 City Water Water Softener Utility DI After Carbon Filter Decon sinks x1 Washer x1 Supply After RO After DI NA <500 Quarterly <10 Monthly NA NA Endotoxin EU/mL LAL Test NA Decon sinks x1 Washer x1 Supply After RO After DI NA NA NA <10 Monthly NA NA JWC Performance Qualification Testing (quarterly) Testing by Vendor Water Quality Measurement Units Type of Testing PQ Sample Site Utility PQ Sample Site Critical Minimum Frequency of Testing and Testing Range Utility Water Critical Water pH pH pH Meter or Colorimetric dipsticks Decon sink x2 Medivator Basin x4 Water Softener City Water Medivator 30 Supply Medivator 31 Supply NA 6.5-9.5 Quarterly 5.0-7.5 Monthly Conductivity uS/cm Conductivity Meter Decon sink x2 Medivator Basin x4 Water Softener City Water Medivator 30 Supply Medivator 31 Supply NA <500 Quarterly <10 Monthly Total Alkalinity mg CaCO3/L Colorimetric dipsticks or Alkalinity test kit Decon sink x2 Medivator Basin x4 Water Softener City Water NA <400 Quarterly <8 Monthly Total Hardness mg CaCO3/L Determination of ppm as CaCO3/L by colorimetric dipsticks, titration kit, or handheld meter Decon sink x2 Medivator Basin x4 Water Softener City Water NA <150 Quarterly <1 Monthly Total Organic Carbon (TOC) mg/L (ppm) NA NA NA NA <1.0 Quarterly Aluminum mg/L Decon sink x2 Medivator Basin x4 Water Softener City Water Medivator 30 Supply Medivator 31 Supply NA <0.1 Quarterly <0.1 Quarterly Chloride mg/L Decon sink x2 Medivator Basin x4 Water Softener City Water Medivator 30 Supply Medivator 31 Supply NA <250 Quarterly <1 Quarterly Copper mg/L Decon sink x2 Medivator Basin x4 Water Softener City Water Medivator 30 Supply Medivator 31 Supply NA <0.1 Quarterly <0.1 Quarterly Iron mg/L Decon sink x2 Medivator Basin x4 Water Softener City Water Medivator 30 Supply Medivator 31 Supply NA <0.1 Quarterly <0.1 Quarterly Manganese mg/L Decon sink x2 Medivator Basin x4 Water Softener City Water Medivator 30 Supply Medivator 31 Supply NA <0.1 Quarterly <0.1 Quarterly Nitrate mg/L Decon sink x2 Medivator Basin x4 Water Softener City Water Medivator 30 Supply Medivator 31 Supply NA <10 Quarterly <1 Quarterly Phosphate mg/L Decon sink x2 Medivator Basin x4 Water Softener City Water Medivator 30 Supply Medivator 31 Supply NA <5 Quarterly <1 Quarterly Silicate mg/L Decon sink x2 Medivator Basin x4 Water Softener City Water Medivator 30 Supply Medivator 31 Supply NA <50 Quarterly <1 Quarterly Sulfate mg/L Decon sink x2 Medivator Basin x4 Water Softener City Water Medivator 30 Supply Medivator 31 Supply NA <150 Quarterly <1 Quarterly Zinc mg/L Decon sink x2 Medivator Basin x4 Water Softener City Water Medivator 30 Supply Medivator 31 Supply NA <0.1 Quarterly <0.1 Quarterly Bacteria CFU/mL Heterotrophic Plate Count (HPC) Decon sink x2 Water Softener City Water Medivator 30 Supply Medivator 31 Supply Medivator Basin x4 <500 Quarterly <10 Monthly Endotoxin EU/mL LAL Test NA Medivator Basin x4 NA NA <10 Monthly JWC Routine (monthly) POU Testing by Vendor Water Quality Measurement Units Type of Testing Routine Sample Site Utility Routine Sample Site Critical Minimum Frequency of Testing and Testing Range Utility Water Critical Water pH pH pH Meter or Colorimetric dipsticks Medivator Basin x4 NA 6.5-9.5 Quarterly 5.0-7.5 Monthly Conductivity uS/cm Conductivity Meter Medivator Basin x4 NA <500 Quarterly <10 Monthly Total Alkalinity mg CaCO3/L Colorimetric dipsticks or Alkalinity test kit Medivator Basin x4 NA <400 Quarterly <8 Monthly Total Hardness mg CaCO3/L Determination of ppm as CaCO3/L by colorimetric dipsticks, titration kit, or handheld meter Medivator Basin x4 NA <150 Quarterly <1 Monthly Bacteria CFU/mL Heterotrophic Plate Count (HPC) NA Medivator Basin x4 <500 Quarterly <10 Monthly Endotoxin EU/mL LAL Test NA Medivator Basin x4 NA NA <10 Monthly Part III Supporting information: All work to be performed during the normal business hours of 7:00a 4:30p, Monday through Friday, excluding National Holidays. excluding federal holidays. Federal holidays are New Year's Day, Martin Luther King Day, President's Day, Memorial Day, Juneteenth, Independence Day, Labor Day, Columbus Day, Veterans Day, Thanksgiving Day, Christmas, and any other day specifically declared by the President of the United States to be a national holiday. Security: The C&A requirements do not apply, and a Security Accreditation Package is not required. Place of Performance: VA Northern Indiana Health Care System (Marion) 1700 E 38th St. Marion, Indiana 46953 VA Northern Indiana Health Care System (Fort Wayne) 2121 Lake Ave. Fort Wayne, Indiana 46805 Jackie Walorski VA Clinic (St. Joseph County VA Health Care Center) 1540 Trinity Place, Mishawaka, IN 46545. Submittals are required for all Products and Services: Provide three hard copies of all specifications of all products: name, ingredients, control range, test procedures, physical state (liquid, powder, etc.), container size, method of delivery, compatibility with present materials being used, catalog data, MSDS sheets

From Sources Sought posted on Apr 15, 2026

Notice history

2
  1. Sources Sought Posted Apr 07, 2026
  2. Sources Sought LATEST Posted Apr 15, 2026
    • Response Deadline: Apr 07, 2026Apr 22, 2026

Details

Solicitation number 36C25026R0060
Notice ID e530a2aa684f4c908ccca740126536e0
Notice type Sources Sought
Product / Service (PSC) B533
NAICS 541380
Place of performance USA
Archive date May 07, 2026

Award Information

Awardees
0

Documents

1
View on SAM.gov

Contacts

primary
Eric Sweatt

Contract Specialist

Email

Phone

Agency

VETERANS AFFAIRS, DEPARTMENT OF
VETERANS AFFAIRS, DEPARTMENT OF
250-NETWORK CONTRACT OFFICE 10 (36C250)

Place of Performance

VA Northern Indiana Health Care System Multiple location - Statement of work for location

USA

Dates

Posted Apr 07, 2026 4 months ago
Last Updated Aug 06, 2026 2 days ago
Due Apr 07, 2026 4 months ago