B1825 LIGHTNING PROTECTION SYSTEM FA462626Q0008
Summary
AI-generated · Mar 03, 2026Upgrade and inspect the facility’s lightning protection system (LPS) per the drawings and specifications, including all labor, materials, equipment, and incidentals needed. LPS cables must be upsized to copper AWG 4/0, and a small quantity of frayed cable will be replaced.
Inspection must comply with the most current NFPA 780 edition. Deliver both a hard copy and a digital CD of the acceptance testing results and the UL Lightning Protection Inspection Certificate, with the UL certificate certified to NFPA 780 Chapter 8. The contractor must have completed the Senior Inspector AMMO 50 training or an equivalent credential. See the attached SOW for full details.
This requirement is to provide all items, articles, materials, operations, or methods listed, mentioned or scheduled on the drawings and/or as specified herein, including all labor, materials, equipment, and incidentals necessary and required for completion of a lightning protection system (LPS) upgrade and inspection. The LPS system cables shall be up sized to AWG 4/0 (approximately ) copper to bring the system up to code, and a small quantity of frayed cable will be replaced. The LPS inspection shall be compliant with the most current edition of NFPA 780. The Contractor shall provide and deliver to the United States Air Force a hard copy and a digital CD of the acceptance testing results and the UL Lightning Protection Inspection Certificate for the facility. The UL Lightning Protection Inspection Certificate shall be certified to NFPA 780 Chapter 8. The Contractor shall have attended and completed the Senior Inspector AMMO 50 training or equivalent. Please See attached SOW for complete details.
From Solicitation posted on Mar 02, 2026This requirement is to provide all items, articles, materials, operations, or methods listed, mentioned or scheduled on the drawings and/or as specified herein, including all labor, materials, equipment, and incidentals necessary and required for completion of a lightning protection system (LPS) upgrade and inspection. The LPS system cables shall be up sized to AWG 4/0 (approximately ) copper to bring the system up to code, and a small quantity of frayed cable will be replaced. The LPS inspection shall be compliant with the most current edition of NFPA 780. The Contractor shall provide and deliver to the United States Air Force a hard copy and a digital CD of the acceptance testing results and the UL Lightning Protection Inspection Certificate for the facility. The UL Lightning Protection Inspection Certificate shall be certified to NFPA 780 Chapter 8. The Contractor shall have attended and completed the Senior Inspector AMMO 47 or better training or equivalent. Please See attached SOW for complete details.
From Solicitation posted on Mar 16, 2026Notice history
2-
Solicitation Posted Mar 02, 2026
-
Solicitation LATEST Posted Mar 16, 2026View changes (2)
- Description: Description was updated
- Response Deadline: Mar 19, 2026 → Mar 20, 2026
Details
Award Information
Not yet awarded