B16 Generator PLC Upgrade PANNGB-26-P-0000029437
Summary
AI-generated · Jan 11, 2026Upgrade work for Building 16’s generator PLC at Kansas Air National Guard, McConnell AFB, involves inspecting, troubleshooting, and repairing or replacing the PLC controls. The PLC is a Telmecanique/Advantys STBNMP2212 with connected output modules that control a Kohler 1.5 MW diesel generator. The contractor must troubleshoot to the original installation parameters, verify restored PLC/generator operations and communications, and complete function checks of the generator in both standalone and parallel modes. There is an option to install a Hot Switch Bypass.
This is a sources sought notice to identify potential sources for planning and market research, including small businesses. A prime contractor is required to subcontract with 3E Company, the designated Kohler OEM regional representative. Respondents should complete the attached sources sought form and provide bonding capability, along with information on capabilities and past performance. (Submission instructions and contact information are provided in the notice.)
This is a SOURCES SOUGHT ANNOUNCEMENT ONLY. The purpose of this sources sought is for market research to gain knowledge of potential sources for future needs including interested small business sources. This notice is for planning purposes only. All interested parties should respond. Kansas Air Nationl Guard, McConnel AFB, Kansas, will soon be soliciting for a project for Building 16 Generator PLC Upgrade. Work shall consist of but is not limited to the following: Inspect, troubleshoot, and repair or replace generator PLC controls. PLC is a Telmecanique/Advantys STBNMP2212 PLC Island and connected output modules controlling a Kohler 1.5 MW Diesel Generator set. Contractor is to troubleshoot and repair PLC to original installation parameters. Verify restored PLC/Generator set operations and communication. Ensure repairs with a function check of generator operations in standalone and parallel modes. There will be an option to install a Hot Switch Bypass. Refer to attached SOW. For this requirement, the small business size standard is $19 million for NAICS 238210. In the event small business contractors are not avaialble for adequate competition for this project, it may be advertised as unrestricted. NOTE: Prime contractor is required to subcontract with 3E Company (electrical Engineering & Equipment Co.) since they are the designated OEM regional representatvie of Kohler. Complete and return attached sources sought form to include bonding capability and advise on your capabilities and or past perfromance in terms of the projected requested. Include the following email subject line "Sources Sought B16 Generator PLC Upgrade" when emailing, to 184WG.MSG.CONTRACTING@us.af.mil. Use the same email address if you have additional questions.
From Sources Sought posted on Jan 10, 2026Notice history
1-
Sources Sought LATEST Posted Jan 10, 2026
Details
Award Information
Not yet awarded
Contacts
Phone
Phone
Agency
Place of Performance
USA