Contacts, documents and full notice history are available with a subscription.
Award Notice SBA 6 notices 1 document

AJJY 25-1074M Repair Saipan Dorm - Andersen AFB, Guam FA524025R0004

Solicitation FA524025R0004 Copied Notice ID 7bbf3ee61dd54a63a705d46148645911 Copied DEPT OF DEFENSE — FA5240 36 CONS LGC
SAM.gov
Posted
Jun 02, 2025
Deadline
Jun 17, 2025
Set-aside
SBA
NAICS
236220
PSC
Z2FC

Summary

AI-generated · Aug 25, 2025

Design-build contractor to design and fully repair Saipan Dorm B25007 at Andersen AFB, Guam. Renovation includes interior improvements (floors, walls, ceilings, finishes) and full restroom modernization, exterior repairs from storm damage, and walkway/slab and spandrel beam repairs with regrading to maintain positive drainage and clearing buried storm sewers. The build-out updates the HVAC and plumbing systems with a complete replacement of the central chilled-water plant, air handlers, ductwork, VAV boxes, piping, and pumps; all plumbing utilities and heat pump water heaters replaced with standard electric storage tanks. Electrical distribution is fully upgraded from the pad-mount transformer to the downstream building distribution. Fire protection includes sprinkler coverage and a mass notification system with a wet-pipe sprinkler network. The work also encompasses exterior renovations related to storm damage and site drainage improvements.

Project is estimated between $25 million and $100 million, with a period of performance of 865 calendar days. Proposals must be submitted electronically through the Procurement Integrated Enterprise Environment (PIEE). A site visit is available to observe the work, and there is a formal RFIs process with Q&A responses and solicitation amendments reflecting RFIs, including updated Statement of Work and attachments such as As-BUILTs and Roofing As-BUILTs. Offerors should monitor the solicitation for amendments.

Andersen Air Force Base, Guam has a Design-Build construction requirement to design and fully repair Saipan Dorm B250007. DESCRIPTION OF WORK: The contractor shall design and fully repair Saipan Dorm B25007 to renovate interiors including floors, walls, ceiling, finishes, full restroom renovation, updating code for Energy and Life Safety, exterior renovations resulting from recent storm damage. Walkway slabs and spandrel beams will be repaired. Repairs will also include a complete update to the HVAC and Plumbing systems. B25007 is conditioned by chilled water and a central chiller plant, and both will be replaced. A complete replacement of air handlers, ductwork, grilles, variable air volume boxes, and chilled water piping will be replaced. The chilled water pump will be replaced. All existing plumbing utilities will be replaced and updated. The existing heat pump water heaters will be replaced with standard electric water heaters with large storage tanks. Electrical updates include an update to the entire electrical distribution system. The system updates will include a complete replacement of electrical distribution from the pad mount transformer secondary conductors to the entire downstream building distribution system. Fire protection updates include sprinkler protection throughout, installation of a mass notification system, and a wet-pipe sprinkler system throughout the dorm. B25007 must be re-graded to maintain positive drainage away from the building. Existing storm sewer inlets buried with debris, dirt, and grass are to be cleared. Please see attachment for more details. Thank you!

From Presolicitation posted on Jun 02, 2025

Andersen Air Force Base, Guam has a Design-Build construction requirement to design and fully repair Saipan Dorm B25007 DESCRIPTION OF WORK The contractor shall design and fully repair Saipan Dorm B25007 to renovate interiors including floors, walls, ceiling, finishes, full restroom renovation, updating code for Energy and Life Safety, exterior renovations resulting from recent storm damage. Walkway slabs and spandrel beams will be repaired. Repairs will also include a complete update to the HVAC and Plumbing systems. B25007 is conditioned by chilled water and a central chiller plant, and both will be replaced. A complete replacement of air handlers, ductwork, grilles, variable air volume boxes, and chilled water piping will be replaced. The chilled water pump will be replaced. All existing plumbing utilities will be replaced and updated. The existing heat pump water heaters will be replaced with standard electric water heaters with large storage tanks. Electrical updates include an update to the entire electrical distribution system. The system updates will include a complete replacement of electrical distribution from the pad mount transformer secondary conductors to the entire downstream building distribution system. Fire protection updates include sprinkler protection throughout, installation of a mass notification system, and a wet-pipe sprinkler system throughout the dorm. B25007 must be re-graded to maintain positive drainage away from the building. Existing storm sewer inlets buried with debris, dirt, and grass are to be cleared. MAGNITUDE FAR 36.204(h) and DFARS 236.204(ii) The magnitude of this project is between $25,000,000 - $100,000,000 LOCATION OF WORK: Andersen AFB, GU PERIOD OF PERFORMANCE 865 Calendar Days RESTRICTION TO SMALL BUSINESS: This acquisition is being competed as a Historically Underutilized Business Zone (HUBZone) Small Business set-aside. The applicable North American Industry Classification System (NAICS) code for this acquisition is 236220 Commercial and Institutional Building Construction with a small business size standard of $45 million. CONTRACT TYPE: Firm Fixed Price (FFP) SITE VISIT: Thursday, 24 July 2025 at 0900 hours ChST (See Solicitation Section L) REQUEST FOR INFORMATION: Any Requests for Information (RFIs) regarding this solicitation are due on or before Thursday, 7 August 2025 at 1600 hours ChST (Local) and shall be submitted electronically via email to the notice POCs. The Government does not intend to respond to inquiries submitted after this deadline. All questions will be answered via Q&A format and amended into the solicitation. It is the offeror's responsibility to monitor SAM.gov for any amendments or changes. Subject line for all correspondence shall contain FA524025R0004, AJJY 25-1074M Repair Saipan Dorm B25007. PROPOSAL SUBMISSION: Proposals shall be submitted electronically through the Procurement Integrated Enterprise Environment (PIEE) at the link below. See Solicitation Section L and the PIEE Proposal Manager Guide (Attachment 8). https://piee.eb.mil/sol/xhtml/unauth/search/oppMgmtLink.xhtml?noticeId=FA524025R0004&noticeType=SolicitationNotice OTHER INFORMATION: Prospective offerors will be required to deliver proposals through the Solicitation Module in the Procurement Integrated Enterprise Environment (PIEE). Offerors are encouraged to ensure access to the Proposal Manager function. See reference links below. Vendor Registration: https://www.acq.osd.mil/asda/dpc/ce/cap/docs/piee/PIEE_Solicitation_Module_Vendor_Access_Instructions.pdf Solicitation Module Training: https://pieetraining.eb.mil/wbt/xhtml/wbt/sol/index.xhtml NOTICE TO OFFERORS: The Government reserves the right to cancel this solicitation, either before or after closing of receipt of bids. GOVERNMENT POINTS OF CONTACT: 2d Lt Shelby Benko; Email: shelby.benko.1@us.af.mil Mr. Darrell P. Chargualaf; Email: darrell.chargualaf@us.af.mil Mr. Eddie C. Pelkey; Email: eddie.pelkey@us.af.mil Ms. Katrina J. Pangelinan; Email: katrina.pangelinan@us.af.mil (END OF SAM SOLICITATION POSTING)

From Solicitation posted on Jul 16, 2025

Andersen Air Force Base, Guam has a Design-Build construction requirement to design and fully repair Saipan Dorm B25007 08 Aug 25* - The amended soliction to reflect the updated Statement of Work is posted along with the As-BUILTs and expanded RFI responses. 08 Aug 25* - The last round of RFIs are posted in the attachment secetion along with the As-BUILTs. The amended Statement of Work to reflect the RFI responses will be posted. 07 Aug 25* - The first round of RFIs are posted in the attachment secetion. There will be more responses posted along with an amended Statement of Work. DESCRIPTION OF WORK The contractor shall design and fully repair Saipan Dorm B25007 to renovate interiors including floors, walls, ceiling, finishes, full restroom renovation, updating code for Energy and Life Safety, exterior renovations resulting from recent storm damage. Walkway slabs and spandrel beams will be repaired. Repairs will also include a complete update to the HVAC and Plumbing systems. B25007 is conditioned by chilled water and a central chiller plant, and both will be replaced. A complete replacement of air handlers, ductwork, grilles, variable air volume boxes, and chilled water piping will be replaced. The chilled water pump will be replaced. All existing plumbing utilities will be replaced and updated. The existing heat pump water heaters will be replaced with standard electric water heaters with large storage tanks. Electrical updates include an update to the entire electrical distribution system. The system updates will include a complete replacement of electrical distribution from the pad mount transformer secondary conductors to the entire downstream building distribution system. Fire protection updates include sprinkler protection throughout, installation of a mass notification system, and a wet-pipe sprinkler system throughout the dorm. B25007 must be re-graded to maintain positive drainage away from the building. Existing storm sewer inlets buried with debris, dirt, and grass are to be cleared. MAGNITUDE FAR 36.204(h) and DFARS 236.204(ii) The magnitude of this project is between $25,000,000 - $100,000,000 LOCATION OF WORK: Andersen AFB, GU PERIOD OF PERFORMANCE 865 Calendar Days RESTRICTION TO SMALL BUSINESS: This acquisition is being competed as a Historically Underutilized Business Zone (HUBZone) Small Business set-aside. The applicable North American Industry Classification System (NAICS) code for this acquisition is 236220 Commercial and Institutional Building Construction with a small business size standard of $45 million. CONTRACT TYPE: Firm Fixed Price (FFP) SITE VISIT: Thursday, 24 July 2025 at 0900 hours ChST (See Solicitation Section L) REQUEST FOR INFORMATION: Any Requests for Information (RFIs) regarding this solicitation are due on or before Thursday, 7 August 2025 at 1600 hours ChST (Local) and shall be submitted electronically via email to the notice POCs. The Government does not intend to respond to inquiries submitted after this deadline. All questions will be answered via Q&A format and amended into the solicitation. It is the offeror's responsibility to monitor SAM.gov for any amendments or changes. Subject line for all correspondence shall contain FA524025R0004, AJJY 25-1074M Repair Saipan Dorm B25007. PROPOSAL SUBMISSION: Proposals shall be submitted electronically through the Procurement Integrated Enterprise Environment (PIEE) at the link below. See Solicitation Section L and the PIEE Proposal Manager Guide (Attachment 8). https://piee.eb.mil/sol/xhtml/unauth/search/oppMgmtLink.xhtml?noticeId=FA524025R0004&noticeType=SolicitationNotice OTHER INFORMATION: Prospective offerors will be required to deliver proposals through the Solicitation Module in the Procurement Integrated Enterprise Environment (PIEE). Offerors are encouraged to ensure access to the Proposal Manager function. See reference links below. Vendor Registration: https://www.acq.osd.mil/asda/dpc/ce/cap/docs/piee/PIEE_Solicitation_Module_Vendor_Access_Instructions.pdf Solicitation Module Training: https://pieetraining.eb.mil/wbt/xhtml/wbt/sol/index.xhtml NOTICE TO OFFERORS: The Government reserves the right to cancel this solicitation, either before or after closing of receipt of bids. GOVERNMENT POINTS OF CONTACT: 2d Lt Shelby Benko; Email: shelby.benko.1@us.af.mil Mr. Darrell P. Chargualaf; Email: darrell.chargualaf@us.af.mil Mr. Eddie C. Pelkey; Email: eddie.pelkey@us.af.mil Ms. Katrina J. Pangelinan; Email: katrina.pangelinan@us.af.mil (END OF SAM SOLICITATION POSTING)

From Solicitation posted on Aug 08, 2025

Andersen Air Force Base, Guam has a Design-Build construction requirement to design and fully repair Saipan Dorm B25007 13 Aug 25* - As stated in the amended soliciation, the updated Statement of Work is posted in the Attachments/Links. 08 Aug 25* - The amended soliction to reflect the updated Statement of Work is posted along with the As-BUILTs and expanded RFI responses. 08 Aug 25* - The last round of RFIs are posted in the attachment secetion along with the As-BUILTs. The amended Statement of Work to reflect the RFI responses will be posted. 07 Aug 25* - The first round of RFIs are posted in the attachment secetion. There will be more responses posted along with an amended Statement of Work. DESCRIPTION OF WORK The contractor shall design and fully repair Saipan Dorm B25007 to renovate interiors including floors, walls, ceiling, finishes, full restroom renovation, updating code for Energy and Life Safety, exterior renovations resulting from recent storm damage. Walkway slabs and spandrel beams will be repaired. Repairs will also include a complete update to the HVAC and Plumbing systems. B25007 is conditioned by chilled water and a central chiller plant, and both will be replaced. A complete replacement of air handlers, ductwork, grilles, variable air volume boxes, and chilled water piping will be replaced. The chilled water pump will be replaced. All existing plumbing utilities will be replaced and updated. The existing heat pump water heaters will be replaced with standard electric water heaters with large storage tanks. Electrical updates include an update to the entire electrical distribution system. The system updates will include a complete replacement of electrical distribution from the pad mount transformer secondary conductors to the entire downstream building distribution system. Fire protection updates include sprinkler protection throughout, installation of a mass notification system, and a wet-pipe sprinkler system throughout the dorm. B25007 must be re-graded to maintain positive drainage away from the building. Existing storm sewer inlets buried with debris, dirt, and grass are to be cleared. MAGNITUDE FAR 36.204(h) and DFARS 236.204(ii) The magnitude of this project is between $25,000,000 - $100,000,000 LOCATION OF WORK: Andersen AFB, GU PERIOD OF PERFORMANCE 865 Calendar Days RESTRICTION TO SMALL BUSINESS: This acquisition is being competed as a Historically Underutilized Business Zone (HUBZone) Small Business set-aside. The applicable North American Industry Classification System (NAICS) code for this acquisition is 236220 Commercial and Institutional Building Construction with a small business size standard of $45 million. CONTRACT TYPE: Firm Fixed Price (FFP) SITE VISIT: Thursday, 24 July 2025 at 0900 hours ChST (See Solicitation Section L) REQUEST FOR INFORMATION: Any Requests for Information (RFIs) regarding this solicitation are due on or before Thursday, 7 August 2025 at 1600 hours ChST (Local) and shall be submitted electronically via email to the notice POCs. The Government does not intend to respond to inquiries submitted after this deadline. All questions will be answered via Q&A format and amended into the solicitation. It is the offeror's responsibility to monitor SAM.gov for any amendments or changes. Subject line for all correspondence shall contain FA524025R0004, AJJY 25-1074M Repair Saipan Dorm B25007. PROPOSAL SUBMISSION: Proposals shall be submitted electronically through the Procurement Integrated Enterprise Environment (PIEE) at the link below. See Solicitation Section L and the PIEE Proposal Manager Guide (Attachment 8). https://piee.eb.mil/sol/xhtml/unauth/search/oppMgmtLink.xhtml?noticeId=FA524025R0004&noticeType=SolicitationNotice OTHER INFORMATION: Prospective offerors will be required to deliver proposals through the Solicitation Module in the Procurement Integrated Enterprise Environment (PIEE). Offerors are encouraged to ensure access to the Proposal Manager function. See reference links below. Vendor Registration: https://www.acq.osd.mil/asda/dpc/ce/cap/docs/piee/PIEE_Solicitation_Module_Vendor_Access_Instructions.pdf Solicitation Module Training: https://pieetraining.eb.mil/wbt/xhtml/wbt/sol/index.xhtml NOTICE TO OFFERORS: The Government reserves the right to cancel this solicitation, either before or after closing of receipt of bids. GOVERNMENT POINTS OF CONTACT: 2d Lt Shelby Benko; Email: shelby.benko.1@us.af.mil Mr. Darrell P. Chargualaf; Email: darrell.chargualaf@us.af.mil Mr. Eddie C. Pelkey; Email: eddie.pelkey@us.af.mil Ms. Katrina J. Pangelinan; Email: katrina.pangelinan@us.af.mil (END OF SAM SOLICITATION POSTING)

From Solicitation posted on Aug 12, 2025

Andersen Air Force Base, Guam has a Design-Build construction requirement to design and fully repair Saipan Dorm B25007 13 Aug 25* - Amended solictiation 002 reflects the added Attachment 9a Roofing As-BUILTs posted in the Attachments/Links. 13 Aug 25* - As stated in the amended soliciation (08 Aug 25), the updated Statement of Work is posted in the Attachments/Links. 08 Aug 25* - The amended soliction to reflect the updated Statement of Work is posted along with the As-BUILTs and expanded RFI responses. 08 Aug 25* - The last round of RFIs are posted in the attachment secetion along with the As-BUILTs. The amended Statement of Work to reflect the RFI responses will be posted. 07 Aug 25* - The first round of RFIs are posted in the attachment secetion. There will be more responses posted along with an amended Statement of Work. DESCRIPTION OF WORK The contractor shall design and fully repair Saipan Dorm B25007 to renovate interiors including floors, walls, ceiling, finishes, full restroom renovation, updating code for Energy and Life Safety, exterior renovations resulting from recent storm damage. Walkway slabs and spandrel beams will be repaired. Repairs will also include a complete update to the HVAC and Plumbing systems. B25007 is conditioned by chilled water and a central chiller plant, and both will be replaced. A complete replacement of air handlers, ductwork, grilles, variable air volume boxes, and chilled water piping will be replaced. The chilled water pump will be replaced. All existing plumbing utilities will be replaced and updated. The existing heat pump water heaters will be replaced with standard electric water heaters with large storage tanks. Electrical updates include an update to the entire electrical distribution system. The system updates will include a complete replacement of electrical distribution from the pad mount transformer secondary conductors to the entire downstream building distribution system. Fire protection updates include sprinkler protection throughout, installation of a mass notification system, and a wet-pipe sprinkler system throughout the dorm. B25007 must be re-graded to maintain positive drainage away from the building. Existing storm sewer inlets buried with debris, dirt, and grass are to be cleared. MAGNITUDE FAR 36.204(h) and DFARS 236.204(ii) The magnitude of this project is between $25,000,000 - $100,000,000 LOCATION OF WORK: Andersen AFB, GU PERIOD OF PERFORMANCE 865 Calendar Days RESTRICTION TO SMALL BUSINESS: This acquisition is being competed as a Historically Underutilized Business Zone (HUBZone) Small Business set-aside. The applicable North American Industry Classification System (NAICS) code for this acquisition is 236220 Commercial and Institutional Building Construction with a small business size standard of $45 million. CONTRACT TYPE: Firm Fixed Price (FFP) SITE VISIT: Thursday, 24 July 2025 at 0900 hours ChST (See Solicitation Section L) REQUEST FOR INFORMATION: Any Requests for Information (RFIs) regarding this solicitation are due on or before Thursday, 7 August 2025 at 1600 hours ChST (Local) and shall be submitted electronically via email to the notice POCs. The Government does not intend to respond to inquiries submitted after this deadline. All questions will be answered via Q&A format and amended into the solicitation. It is the offeror's responsibility to monitor SAM.gov for any amendments or changes. Subject line for all correspondence shall contain FA524025R0004, AJJY 25-1074M Repair Saipan Dorm B25007. PROPOSAL SUBMISSION: Proposals shall be submitted electronically through the Procurement Integrated Enterprise Environment (PIEE) at the link below. See Solicitation Section L and the PIEE Proposal Manager Guide (Attachment 8). https://piee.eb.mil/sol/xhtml/unauth/search/oppMgmtLink.xhtml?noticeId=FA524025R0004&noticeType=SolicitationNotice OTHER INFORMATION: Prospective offerors will be required to deliver proposals through the Solicitation Module in the Procurement Integrated Enterprise Environment (PIEE). Offerors are encouraged to ensure access to the Proposal Manager function. See reference links below. Vendor Registration: https://www.acq.osd.mil/asda/dpc/ce/cap/docs/piee/PIEE_Solicitation_Module_Vendor_Access_Instructions.pdf Solicitation Module Training: https://pieetraining.eb.mil/wbt/xhtml/wbt/sol/index.xhtml NOTICE TO OFFERORS: The Government reserves the right to cancel this solicitation, either before or after closing of receipt of bids. GOVERNMENT POINTS OF CONTACT: 2d Lt Shelby Benko; Email: shelby.benko.1@us.af.mil Mr. Darrell P. Chargualaf; Email: darrell.chargualaf@us.af.mil Mr. Eddie C. Pelkey; Email: eddie.pelkey@us.af.mil Ms. Katrina J. Pangelinan; Email: katrina.pangelinan@us.af.mil (END OF SAM SOLICITATION POSTING)

From Solicitation posted on Aug 13, 2025

This is a pre-award notice for Solicitation FA524025R0004: AJJY 25-1074M Repair Saipan Dorm B25007, Andersen Air Force Base, Guam

From Award Notice posted on Sep 25, 2025

Notice history

6
  1. Presolicitation Posted Jun 02, 2025
  2. Solicitation Posted Jul 16, 2025
    • Title: AJJY 25-1074M Repair Saipan Dorm - Andersen AFB, GuamAJJY 25-1074M Repair Saipan Dorm B25007
    • Description: Description was updated
    • Notice Type: PresolicitationSolicitation
    • Response Deadline: Jun 17, 2025Aug 18, 2025
    • Set-Aside: Total Small Business Set-Aside (FAR 19.5)HUBZone Set Aside
  3. Solicitation Posted Aug 08, 2025
    • Description: Description was updated
  4. Solicitation Posted Aug 12, 2025
    • Description: Description was updated
  5. Solicitation Posted Aug 13, 2025
    • Description: Description was updated
  6. Award Notice LATEST Posted Sep 25, 2025

Details

Solicitation number FA524025R0004
Notice ID 7bbf3ee61dd54a63a705d46148645911
Award number FA524025C0008
Notice type Presolicitation
Product / Service (PSC) Z2FC
NAICS 236220
Place of performance Yigo, Guam
Archive date Jul 02, 2025

Award Information

Awardee
1
Total Awarded
$35,419,888.00
Award Date
Sep 26, 2025

Award Notices

AJJY 25-1074M Repair Saipan Dorm B25007 View Notice

Posted: Sep 25, 2025

This is a pre-award notice for Solicitation FA524025R0004: AJJY 25-1074M Repair Saipan Dorm B25007, Andersen Air Force Base, Guam

Awardees

Company Name UEI CAGE Code Location
PACIFIC RIM CONSTRUCTORS INC UKFCF2NY4AA3 7KU41 Tamuning, GU

Documents

1
View on SAM.gov

Contacts

primary
Lt Shelby Benko

Email

Phone

secondary
Mr. Eddie Pelkey

Email

Phone

Agency

DEPT OF DEFENSE
DEPT OF THE AIR FORCE
PACIFIC AIR FORCES
FA5240 36 CONS LGC

Place of Performance

Yigo, Guam 96929
USA

Dates

Posted Jun 02, 2025 1 year ago
Last Updated Aug 05, 2026 2 days ago
Due Jun 17, 2025 1 year ago