Contacts, documents and full notice history are available with a subscription.
Combined Synopsis/Solicitation SDVOSBC Expired 1 notice 2 documents

7320--Industrial Kitchen Cart Washer 36C24525Q0824

Solicitation 36C24525Q0824 Copied Notice ID e0e25d69eae14b41903e08512478c34c Copied VETERANS AFFAIRS, DEPARTMENT OF — 245-NETWORK CONTRACT OFFICE 5 (36C245)
SAM.gov
Posted
Sep 06, 2025
Deadline
Sep 12, 2025
Set-aside
SDVOSBC
NAICS
333310
PSC
7320

Summary

AI-generated · Sep 09, 2025

Procure and deliver an industrial cart washer (brand-name or equal to ALVEY KS-88) for the Louis A. Johnson VA Medical Center renovation. The unit must be a thorough, pass-through design with a 102" L x 36" W x 80" H wash chamber, built of 304 stainless steel, with dual counter-rotating spinning arms, stainless wash nozzles, and a stationary brass rinse system. It should provide 23.5 gallons of fresh rinse water per cycle, a 15 HP TEFC wash pump delivering 400 GPM at 35 PSI, and a 225 gallon (290 gallon if gas heat) wash/rinse tank. Features include front and rear pass-through doors (38" x 83" opening), UL/NEMA 4X control panel with three preset cycles, automatic water fill, electronic/indicator temperature controls, wash and rinse pressure gauges, NSF certification, pit-mounted design, safety guard rails, anti-slip floor, a high-capacity exhaust, wash-down hose/nozzle, and stainless steel steam-heated coils with a warm rinse steam booster. Insulation is not included and must be supplied by the customer; the customer must provide gas/steam/water pressure regulation capabilities and related regulators or valves not included.

Delivery and coordination details: delivery requested within 60 days of order, with installation not required but training provided after scheduled service installation. Shipping information must be provided to the VA Clarksburg team and the designated recipient (Beth Bova) prior to delivery; failure to coordinate may result in delivery being refused and redelivered at no cost to the government. The order is brand-name or equal to the ALVEY KS-88, and the equipment is to be delivered to the specified VA location.

ALVEY KS-88 INDUSTRIAL CART WASHER Brand name or Equal Scope of Work The contractor shall deliver the unit to the location stated below. Louis A. Johnson VAMC is drawing up a contract for renovation and the facility is seeking new equipment. Specifications Salient Characteristics: Features Include: Wash Chamber section Wash chamber 102 long, 36 wide, and 80 height Constructed of type 304 stainless steel with polished finish Panel-Z type interlocking double flange type seal Two counter-rotating stainless steel spinning arm assemblies Stainless steel wash nozzles Stationary fresh water rinse on top and sides with brass nozzles 23.5 gallons of fresh rinse water to replenish wash tank each cycle Wash Pump 15 HP TEFC (totally enclosed fan cooled) motor, vertically mounted pump delivering 400 GPM at 35 PSI Stainless steel wash and rinse pipes Pump protection screen Tank and Housing Tank constructed of 12 gauge type 304 stainless steel Housing constructed of 16 gauge type 304 stainless steel Removable stainless steel filter screens 225 gallon tank capacity (290 if gas heat) Door(s) Pass-Thru front and rear entry walk-through design 38 wide x 83 high opening Interior safety release latch Triple hung (3 hinges) for added durability Control Panel UL listed NEMA 4X stainless steel panel Three pre-set cycle times Automatic water fill Electronic temperature control Digital wash and rinse temperature indicators Wash and rinse pressure gauges Additional Features NSF certified Pit mounted design Safety guard rail Anti-slip floor Washer shipped knocked down for field assembly High capacity exhaust fan Wash down hose and nozzle Heating Stainless steel steam heated coils Warm rinse steam heat booster NOTE: Insulation (piping or otherwise) is not included and is to be provided and applied by customer. Pressure regulation of the gas, steam, and / or water utilities is required for proper operation of this equipment. Gas regulators and pressure reducing valves are not included and are the customer s responsibility to provide to ensure the specified operating pressures & ranges are maintained. Voltage 220/240V/3PH/60HZ Delivery Location Attn: (Beth Bova) BOVA Corporation 111 McFann Rd Valencia, PA 16059 Email: beth@bovacorp.com Prior to delivery, Contracting Officer Representative and/or Service Line Representative shall receive shipping information from Contractor and forward to Beth Bova and Logistics using the email(s) listed above. The Contractor must comply and provide all necessary information to VA Clarksburg. Otherwise, the delivery may be refused and require redelivery at no additional cost to the government. Requested Delivery Date Delivery of equipment is requested to occur with 60-days after receipt of order. While installation is not required, once our service installs the equipment, training will be required once it is scheduled by the service.

From Combined Synopsis/Solicitation posted on Sep 06, 2025

Notice history

1
  1. Combined Synopsis/Solicitation LATEST Posted Sep 06, 2025 View

Details

Solicitation number 36C24525Q0824
Notice ID e0e25d69eae14b41903e08512478c34c
Notice type Combined Synopsis/Solicitation
Product / Service (PSC) 7320
NAICS 333310
Place of performance Valencia, PA. 16059
Archive date Sep 22, 2025

Award Information

Awardees
0

Contacts

primary
Theresa Thomas

Contracting Officer

Email

Agency

VETERANS AFFAIRS, DEPARTMENT OF
VETERANS AFFAIRS, DEPARTMENT OF
245-NETWORK CONTRACT OFFICE 5 (36C245)

Place of Performance

C/O Department of Veterans Affairs at Clarksburg WV VA Medical Center
BOVA Corporation Attn. Beth Bova 111 McFann Rd
Valencia, PA. 16059
USA

Dates

Posted Sep 06, 2025 11 months ago
Last Updated Aug 06, 2026 2 days ago
Due Sep 12, 2025 10 months ago