Contacts, documents and full notice history are available with a subscription.
Sources Sought Expired 1 notice 1 document

6650--Scanning Systems: Laser: Optical Biometry 36C24526Q0256

Solicitation 36C24526Q0256 Copied Notice ID fa6a276d6b884651922905f7d6d7f727 Copied VETERANS AFFAIRS, DEPARTMENT OF — 245-NETWORK CONTRACT OFFICE 5 (36C245)
SAM.gov
Posted
Jan 29, 2026
Deadline
Feb 20, 2026
Set-aside
None
NAICS
334510
PSC
6650

Summary

AI-generated · Jan 30, 2026

A VA facility is seeking a Scanning System: Laser: Optical Biometry capable of performing accurate biometry, keratometry, and intraocular calculations including toric lens power, with particular effectiveness in difficult cataract cases. Measurements must be non-contact and obtained via two-dimensional swept-source OCT, with the ability to read dense cataracts. The unit should be compact and ergonomic, with patient positioning features (adjustable chin rest, head support) and be compatible with standard US electrical outlets, FDA-approved for ophthalmic biometry, and ISO-compliant.

Interoperability and data management requirements include automated data transfer with the ZEISS FORUM ophthalmic data system (bidirectional exchange), and DICOM compatibility to interface with electronic medical records such as VISTA. Vendors should provide descriptive literature showing conformance to the specified salient characteristics and may propose additional beneficial solutions, clearly identifying brand names and part numbers. Responses should also address (or confirm) the availability and scope of any annual service plans (covering software, parts, or both), whether service is provided by OEM or a subcontractor, and include full company details (DUNS, CAGE, SAM), country of origin, and an OEM distributor letter; capability statements are optional.

REQUEST FOR INFORMATION This RFI is being sent solely for information and planning purposes and does not constitute a solicitation or obligation on the part of the Government. Per FAR 15.201(e), responses to this notice are not considered offers, shall not be used as a proposal, and cannot be accepted by the Government to form a binding contract. Neither unsolicited proposals nor any other kinds of offers will be considered in response to this notice. No evaluation letters and/or results will be issued to the respondents; however, the Government does reserve the right to contact any respondent and/or respondent reference to obtain additional information. At this time, no solicitation exists; therefore, please do not request a copy of the solicitation. Any resulting procurement action will be the subject of a separate, future announcement. The information is provided for discussion purposes and any potential strategy for this acquisition may change prior to any solicitation release. The acquisition strategy, evaluation methodology, contract type, and any other acquisition decisions are to be determined. The Department of Veteran Affairs located at Huntington VAMC located at 150 Spring Valley Dr., Huntington, WV 25704 is seeking a Scanning System: Laser: Optical Biometry. The associated North American Industrial Classification System (NAICS) code for this procurement is 334510- Electromedical and Electrotherapeutic Apparatus Manufacturing, size standard is 1,250 employees. Salient Characteristics: Perform accurate biometry, keratometry and intraocular calculations including toric lenses, especially in difficult cataract cases. Measurements must be obtained via non-contact. Measurements obtained via two-dimensional swept-source OCT (SS-OCT). Must have ability to obtain biometry readings on dense cataracts. Automated data transfer: Must be capable of seamlessly integrating with ophthalmic data management systems already in place to eliminate manual data entry errors. The data management system in place is the ZEISS FORUM. Must be capable of transferring data via ZEISS FORUM into the biometry unit and vice versa. DICOM compatibility: Must be DICOM-compliant to interface with electronic medical record systems i.e. VISTA. Physical and Operational Requirements Must have a compact and ergonomical design. Must include patient positioning features. Adjustable chin rest. Head support for stable measurements. Must be compatible with standard U.S. electrical outlets. Must be FDA-approved for use in ophthalmic biometry and comply with ISO standards for medical devices. Responses: The response must include descriptive literature demonstrating the product meets or exceeds the salient characteristics specified above. The Government's intent is to include all ancillary items to ensure the equipment can function as designed by the Original Equipment Manufacturer (OEM) and as clinically required. Vendors are encouraged to provide any product solution or configuration so long as they meet the salient characteristics. Additionally, responses can include any additional product that may be beneficial. These items must be clearly identified by brand name and part number. Responses to this Sources Sought Notice shall include the following: Does vendor offer an annual service plan, Yes or No? If Yes: What does the plan cover? Does plan cover software updates only? Does the plan cover parts repair or replacement only? Does the plan cover both software and parts? Vendor are requested to provide documentation that shows information on their service plan. Is the service provided by the OEM or a subcontractor? Full name and address of company DUNS number/ CAGE Code/ SAM UIE Business Size Manufacturer or Distributor If distributor provide full name, business size and address of manufacturer. Country of Origin designation for all products MUST COMPLETE THIS SECTION Technical Literature that clearly shows product(s) meet the identified salient characteristics and page numbers where each salient characteristic is met. Any additional product solution or configuration that would be beneficial to the clinical functionality of the product line identified. Authorized Distributor Letter Certified by OEM with a current date. Although not required, vendors responding to this Sources Sought may also submit a Capabilities Statement.

From Sources Sought posted on Jan 29, 2026

Notice history

1
  1. Sources Sought LATEST Posted Jan 29, 2026

Details

Solicitation number 36C24526Q0256
Notice ID fa6a276d6b884651922905f7d6d7f727
Notice type Sources Sought
Product / Service (PSC) 6650
NAICS 334510
Place of performance Huntington, West Virginia
Archive date Apr 21, 2026

Award Information

Awardees
0

Documents

1
View on SAM.gov

Contacts

primary
ALISON KLEIN

CONTRACTING OFFICER

Email

Phone

DYLAN GORE

Agency

VETERANS AFFAIRS, DEPARTMENT OF
VETERANS AFFAIRS, DEPARTMENT OF
245-NETWORK CONTRACT OFFICE 5 (36C245)

Place of Performance

HUNTINGTON VAMC 1540 SPRING VALLEY DR
Huntington, West Virginia 25704
USA

Dates

Posted Jan 29, 2026 6 months ago
Last Updated Aug 06, 2026 2 days ago
Due Feb 20, 2026 5 months ago