6520--DENTAL EQUIPMENT 36C24725Q0851
Summary
AI-generated · Aug 24, 2025Two line items: 2 each NOMAD Pro 2 Handheld X-ray System (Part 844-0019) for portable and forensic dentistry, and 1 each Planmeca ProMax 3D CBCT unit (Part 445-1881) with a selectable field of view from 5x5 cm to 11x8 cm for versatile 2D/3D dental and maxillofacial imaging. This procurement is being pursued as a sole-source award to Henry Schein, which does not use subcontractors or resellers; no competitive quotes will be sought unless information is supplied showing similar products meeting the stated salient characteristics.
Salient features include: NOMAD Pro 2 handheld X-ray system with 21.6 V DC lithium-ion battery, 60 kV, 2.5 mA, exposure range 0.02–1.00 s, 0.4 mm focal spot, 20 cm source-to-skin distance, 60 mm X-ray field, maximum duty cycle 1:60, weight 6 lb, and compact dimensions. Planmeca ProMax 3D CBCT unit: 60–120 kV, 1–14 mA, 0.5 mm focal spot, flat-panel detector, 9–33 s scan times, 2–30 s recon, multiple dental/ENT programs with various max volume sizes, weight about 289 lb, space requirements roughly 135 cm by 145 cm by up to 239 cm in height (cephalostat option increases footprint). Interested parties may submit capability statements for consideration, but SAM registration is required to be eligible.
***INTENT TO SOLE SOURCE NOTICE-*** Estimated Date of Award: August 6, 2025 Synopsis: The Department of Veterans Affairs, VA Columbia Healthcare System located at 6439 Garners Ferry Road, Columbia, SC 29209 intends to make a direct award to Henry Schein located at 135 Duryes Road, Melville, NY 11747 for the purchase two separate line items, specifically line item 1 which is for 2 each, Part Number: 844-0019, NOMAD Pro 2 Handheld X-ray System, which is used for portable and forensic dentistry. It is designed for operator safety and patient acceptance. and line item 2, which is for 1 each of part number 445-1881, Planmeca ProMax 3D series cone beam computed tomography (CBCT) unit that offers a selectable field of view (FOV) from 5x5 cm to 11x8 cm. It's designed for versatile dental and maxillofacial imaging, providing both 2D and 3D capabilities. Henry Schein does not utilize subcontractors or resellers on purchases, so there is no competitive group. Thus, a sole source acquisition strategy is being selected. The NAICS code utilized for this procurement is 339113 with a Small Business Size Standard of 800 Employees. THIS NOTICE OF INTENT IS NOT A REQUEST FOR COMPETITIVE QUOTES. However, Contractors may submit a capability statement, proposal, or quotation which shall be considered by the contracting officer whether to continue with the sole source procurement or to provide for competition, should information be made available to the Contracting Officer to document similar products which meet or exceed the stated salient characteristics identified below. Part Number: 844-0019, NOMAD Pro 2 Handheld X-ray System Salient Characteristics Battery - 21.6 V DC Lithium Ion Voltage - 60 kV true DC Current - 2.5mA Exposure time range - 0.02 - 1.00s Focal spot - 0.4mm Inherent Filtration - > 1.5 mm Al equivalent Source to skin distance - 20 cm X-ray field - 60 mm round Maximum duty cycle - 1:60 Total weight - 6.0 lbs (2.7kg) Approvimate Dimensions - W 5.5'' x L 11'' x H 10.5" (W 14 cm x L 28 cm x H 27 cm) Part number 445-1881, Planmeca ProMax 3D series cone beam computed tomography (CBCT) unit Salient Characteristics Anode voltage 60 90 kV, 60 120 kV Anode current 1 14 mA Focal spot 0.5 mm, fixed anode Image detector Flat panel Image acquisition 200 / 360-degree rotation Scan time 9 33 s Typical reconstruction time 2 30 s Maximum volume sizes Maximum volume with a single scan 20 x 10 cm Dental programs Volume size (child mode) [cm] Tooth 4 x 5 ( 3.4 x 4.2) 4 x8 ( 3.4 x 6.8) Teeth 8 x 5 ( 6.8 x 4.2) 8 x 8 ( 6.8 x 6.8) 10 x 6 ( 8.5 x 5) 10 x 10 ( 8.5 x 8.5) Jaw 16 x 6 ( 16 x 6) 16 x 10 ( 16 x 10) 20 x 6 ( 20 x 6) 20 x 10 ( 20 x 10) ENT (Ear, Nose, Throat) programs Volume size (child mode) [cm] Nose 8 x 8 ( 6.8 x 6.8) Sinus 10 x 10 ( 10 x 10) 16 x 10 ( 16 x 10) 20 x 10 ( 20 x 10) Middle ear 4 x 5 ( 3.4 x 4.2) 8 x 8 ( 6.8 x 6.8) Temporal bone 8 x 8 ( 6.8 x 6.8) Vertebrae 8 x 8 ( 6.8 x 6.8) Airways 8 x 8 ( 6.8 x 6.8) Physical space requirements Width 135 cm (53.2 in.) Depth 145 cm (57 in.) Height* 173 239 cm (68.1 94.1 in.) Weight 131 kg (lbs 289) With cephalostat: Width 222 cm (87.4 in.) Depth 145 cm (57 in.) Height* 173 239 cm (68.1 94.1 in.) *The maximum height of the unit can be adjusted for offices with limited ceiling space. Such responses MUST be received no later than July 28,2025 at 10:00AM EST. All documents submitted will not be returned. All interested parties shall submit clear and convincing documentation demonstrating their capabilities to satisfy the requirement listed to forward responses by e-mail to Joseph Locke, Contracting Officer, joseph.locke@va.gov. Responses received will be evaluated; however, a determination by the Government not to compete with the proposed procurement based upon responses received to this notice is solely within the discretion of the Government. The Department of Veterans Affairs, NCO 7, will NOT be responsible for any costs incurred by interested parties in responding to this notice of intent. Only written responses will be considered. All responses from responsible sources will be fully considered. As a result of analyzing responses to this notice of intent, the Government shall determine if a solicitation will be issued. Any prospective contractor must be registered in the System for Award Management (SAM) to be eligible for the award.
From Combined Synopsis/Solicitation posted on Jul 22, 2025Notice history
1Details
Award Information
Contacts
Contracting Officer
Phone
000-000-0000
Agency
Place of Performance
. 6439 Garners Ferry Road
Columbia, South Carolina 29209
USA