6515--TONOMETER (Band Name or Equal) 36C25226Q0316
Summary
AI-generated · Mar 10, 2026Identify qualified sources able to supply a Brand Name or Equal TONOMETER-II with ARK tonometry for the Tomah VA Medical Center, meeting the detailed technical specifications listed (including refractive, keratometry, and corneal measurements; intraocular pressure range; axis; pupil and corneal size data; and non-contact tonometry with auto-tracking and automatic data capture). The device must support both the specified measurements and auto-tracking in X–Y–Z directions, with the non-contact mode capable of measuring 1–60 mmHg and a working distance of at least 11 mm, plus a built-in inner fixation light.
Respondents should include company information, an indication of which business category applies (SDVOSB, VOSB, small or emerging small, or other than small), a capability statement addressing the vendor’s ability to meet the requirements, documentation showing authorization as an authorized distributor for the manufacturer, and any applicable FSS/SEWP contract numbers, UIE, and Tax ID. Provide responses in writing, with all requested items, by the stated deadline; this is a sources-sought market research effort and not a request for quotes, and telephonic inquiries will not be accepted.
THIS IS A SOURCES SOUGHT NOTICE ONLY. THIS IS NOT A REQUEST FOR QUOTE. The NCO 12, Great Lakes Acquisition Center, 115 S. 84th Street, Suite 101, Milwaukee, WI 53214, is performing market research to determine if there is a sufficient number of qualified: (1) Service-Disabled Veteran Owned Small Business (SDVOSB); (2) Veteran Owned Small Business (VOSB); or (3) Small or emerging small business firms, or (4) Other Than Small business firms, to provide a Brand Name or Equal TONOMETER to the Tomah VA Medical Center 500 E. Veterans Street Tomah, WI 54660-3105. Brand Name : TONOMETER-II, ARK WITH TONOMETRY DESCRIPTION OF SUPPLIES Manufacturer Manufacturer Part No QUANTITY TONOMETER-II, ARK WITH TONOMETRY NIDEK TONOMETER-II, ARK WITH TONOMETRY 1 General Requirements: Salient Characteristics: (Brand Name or Equal) Refraction measurement range must be no less than -30.00D TO +25.00D (Spherical) and 0.00D to 12.00D (cylindrical) Keratometry measurement range must be no less than 5.00mm to 13.00mm in radius curvature Intraocular Pressure Range shall be From 7mm to 60mmHg Axis SHALL BE NO LESS THAN 0 to 180 (1/5 increments) Minimum Measurable Pupil Diameter SHALL NOT BE LESS THAN 2mm Radius Curvature Range must be no less than 5.00 to 13.00mm (0.01mm increments) Corneal Refractive Power shall not be less than 25.96D to 67.50D (n=1.3375), (0.01/0.12/0.25D increments) Must be able to Auto Track & Automatic Data Capture X-Y-Z direction, Automatic Data Capture PD Measurable range no less than 30.00mm to 85.00mm (indication increments: 1mm) Corneal Size (CS) range shall be no less than 8.1mm 14.6mm (indication increments: 0.1mm) Pupil Size (PS) range shall be no less than 0.8mm 12.1mm (indication increments: 0.1mm) NON-CONTACT TONOMETER: Must be able to measure from 1mm Hg to 60mm hg Working distance no less than 11.0mm Must include inner fixation light All interested firms who can meet the requirements stated above should respond, in writing, INCLUDING ALL THE FOLLOWING: Company name. Address. Point of contact (name/title/telephone number/e-mail address). FSS / SEWP Contract number, if applicable. UIE number. Tax ID number. Indication of which business category (SDVOSB, VOSB, Small Business or Other Than Small Business) for which the organization qualifies. A capability statement that addresses the organizations qualifications and ability to provide the requirement depicted above. Documentation from manufacturer (i.e. correspondence from manufacturer) of your firm being an authorized distributor for the manufacturer. Submit responses to the Contracting Specialist, Waymon McNeal, at Waymon.McNealjr@va.gov no later than 3:00 PM (Central Standard Time), 11 March 2026. 36C25226Q0316 TONOMETER shall be referenced on all correspondence regarding this announcement. TELEPHONIC INQUIRIES WILL NOT BE ACCEPTED. The NAICS Code 339112 Surgical and Medical Instrument Manufacturing, is applicable to this acquisition; the size standard is 1000 employees. Interested firms are reminded that in accordance with FAR 4.12, prospective contractors shall complete electronic annual representations and certifications in conjunction with FAR 4.11 required registration in the Systems for Award Management (SAM) database prior to award of a contract. The Government will use responses to this notice to make an appropriate acquisition decision. This is the only notice; no other copies of this notice will be provided.
From Sources Sought posted on Mar 04, 2026Notice history
1-
Sources Sought LATEST Posted Mar 04, 2026
Details
Award Information
Contacts
Contracting Officer
Phone
Agency
Place of Performance
500 E. Veterans Street
Tomah, Wisconsin 54660-3105
USA