Contacts, documents and full notice history are available with a subscription.
Combined Synopsis/Solicitation SBA Expired 2 notices 1 document

Oximeters Nellcor™ Portable SpO2 Patient Monitoring System, Model PM10 Brand Name or Equal 36C24125Q0631

Solicitation 36C24125Q0631 Copied Notice ID 3e425963064c4dfaaa822d1fe68334a4 Copied VETERANS AFFAIRS, DEPARTMENT OF — 241-NETWORK CONTRACT OFFICE 01 (36C241)
SAM.gov
Posted
Jul 31, 2025
Deadline
Aug 05, 2025
Set-aside
SBA
NAICS
339112
PSC
6515

Summary

AI-generated · Aug 27, 2025

The notice requests market information from industry to identify sources capable of supplying the Nellcor PM10N portable SpO2 patient monitoring system (brand-name or equal) and related accessories, with a handheld monitor and compatible probes/covers. The government outlines detailed device requirements (display SpO2 and heart rate, backlit display, broad SpO2 and pulse rate ranges with specified accuracy, alarms, self-test, replaceable battery, cable length, and hand-held form), along with regulatory and business prerequisites (FDA clearance with pre-market approval, SAM registration, potential SD/VOSB VetCert proof, place of manufacture). Respondents must provide company data, capability details, a point of contact, socio-economic status, and other documentation, and responses are for market research only with no quotes or contracts awarded or paid for responses.

The second notice is a combined synopsis/solicitation for the same PM10 system (brand-name or equal), indicating a move from market research to formal procurement. An awards section is present but shows no award amount yet, suggesting a future solicitation process and potential award. Vendors should anticipate a formal procurement and prepare to submit bids that meet the same brand-name-or-equal requirements and device specifications.

THIS IS A SOURCES SOUGHT NOTICE ONLY: This announcement seeks information from the industry, which will be used for preliminary planning purposes for procurement. No quotes are being requested or accepted with this synopsis. THIS IS NOT A SOLICITATION FOR QUOTES AND NO CONTRACT SHALL BE AWARDED FROM THIS SYNOPSIS. THIS IS STRICTLY MARKET RESEARCH. Medtronic/Coviden Nellcor Portable SpO2 Patient Monitoring System, Model PM10N, brand name or equal, domestic and non-domestic. The purpose of this synopsis is to gain knowledge of interest, capabilities, and qualifications of various members of industry, who have the capability to provide the following items: ITEM NUMBER DESCRIPTION QUANTITY UNIT OF MEASURE 0001 PM10N PORTABLE SpO2 PATIENT MONITOR 34 EA 0002 PMAC10N-G PORTABLE SpO2 COVER GREEN 34 EA 0003 DS100A-1 DURASENSOR ADULT FINGER CLIP 1 BX 0004 DURA-Y SENSOR 34 EA 0005 DURA-Y SENSOR EAR 34 EA All interested firms must be registered in SAM (System for Award Management) to be eligible for the award of Government contracts. Interested parties responding to this Sources Sought request shall submit the following information at a minimum: (1) Company name and address point of contact with phone number and SAM UEI. (2) Documentation relating to performance capability, current point of contact, and phone number). (3) Socio-economic status to identify the business class as a large business, SDVOSB, VOSB, small business, Woman Owned, etc. (4) Place of manufacture (5) Any other pertinent company documentation prior to submission of offers to a solicitation. Any SD/VOSB firms responding to this Sources Sought Notice must also provide proof of registration in the SBA Vet Cert prior to submitting offers to a solicitation. This market research is for informational and planning purposes. This is not a solicitation and does not obligate the Government to issue a solicitation. Please be advised that the government will not pay any costs for responses and information submitted. All submissions are acceptable via manases.cabrera@va.gov RESULTS INFORMATION: Respondents will not be notified of the results, and it is at the discretion of the Government to utilize results. Firms responding to this Sources Sought announcement, who fail to meet all requirements as stated above, and who fail to provide ALL the required information requested, will not be used to help the Government make the acquisition decision, which is the intent of this sources sought announcement. FDA Clearance Must have pre-market approval Stand-Alone / Modular Must be a handheld device Displays Must display Sp02 and heart rate. Signal strength is added value. Display must be backlit and easily visible in the dark. Sp02 Range must be greater than 1-100% Accuracy must be +/- 3%, added value if accuracy is +/- 2% or more accurate. Pulse Rate Range must be greater than 30-240bpm, added value if range is closer to 20-300bpm Accuracy must be +/- 5bpm including with motion. Added value if accuracy is +/- 2bpm or more accurate. Perfusion Index And/Or Signal Strength Indicator Signal strength indicator is added value. Response Time Added value for lower response times Alarms Must be visual and audible Patient alarms must include out-of-range Sp02 and heart rate. Equipment alarms must include low battery and probe disconnection User must be able to control volume and/or silence alarm Self-Test Mode Must offer self-test mode Probe Types Must include reusable adult digit and ear probes Cable length must be greater than 2 ft Dimensions and Weight Must fit comfortably in the user's hand Battery Must have replaceable battery option

From Sources Sought posted on Jul 08, 2025

Oximeters Nellcor Portable SpO2 Patient Monitoring System, Model PM10 Brand Name or Equal

From Combined Synopsis/Solicitation posted on Jul 31, 2025

Notice history

2
  1. Sources Sought Posted Jul 08, 2025 View
  2. Combined Synopsis/Solicitation LATEST Posted Jul 31, 2025
    • Title: 6515--Oximeters Nellcorâ„¢ Portable SpO2 Patient Monitoring System, Model PM10Oximeters Nellcor™ Portable SpO2 Patient Monitoring System, Model PM10 Brand Name or Equal
    • Description: Description was updated
    • Notice Type: Sources SoughtCombined Synopsis/Solicitation
    • Response Deadline: Jul 15, 2025Aug 05, 2025
    • Set-Aside: NoneTotal Small Business Set-Aside (FAR 19.5)

Details

Solicitation number 36C24125Q0631
Notice ID 3e425963064c4dfaaa822d1fe68334a4
Notice type Combined Synopsis/Solicitation
Product / Service (PSC) 6515
NAICS 339112
Place of performance Bedford, Massachusetts
Archive date Aug 20, 2025

Award Information

Awardees
0

Documents

1
View on SAM.gov

Contacts

primary
Manases Cabrera

Email

Phone

Agency

VETERANS AFFAIRS, DEPARTMENT OF
VETERANS AFFAIRS, DEPARTMENT OF
241-NETWORK CONTRACT OFFICE 01 (36C241)

Place of Performance

Bedford, Massachusetts 01730
USA

Dates

Posted Jul 31, 2025 1 year ago
Last Updated Aug 06, 2026 1 day ago
Due Aug 05, 2025 1 year ago