Contacts, documents and full notice history are available with a subscription.
Special Notice Expired 1 notice 1 document

6515--Notice of Intent to Sole Source to Stryker Endoscopy 36C24225Q0799

Solicitation 36C24225Q0799 Copied Notice ID 528ac5f061564cf5a18891c0c419c04c Copied VETERANS AFFAIRS, DEPARTMENT OF — 242-NETWORK CONTRACT OFFICE 02 (36C242)
SAM.gov
Posted
Jun 30, 2025
Deadline
Jul 14, 2025
Set-aside
None
NAICS
339113
PSC
6515

Summary

AI-generated · Aug 26, 2025

The VA medical center intends to award a sole-source, firm-fixed-price contract to Stryker Endoscopy for an FCC-compliant endoscopy surgical system that is compatible with the center’s existing Stryker equipment. Market research identified the 1688 Stryker Endoscopic Surgical System as meeting the mandatory requirements, including a camera control unit that supports both 1080p and 4K within a single console, integrated device control from the camera head, shutter lighting with automatic adjustment, a safety feature to turn the light off if the cable is disconnected, near-infrared illumination for fluorescence imaging using indocyanine green and ureter transillumination, and compatibility with existing Stryker arthroscopy cannulas and hardware.

It is determined that only one source is reasonably available to meet these salient characteristics, and Stryker Endoscopy has positioned itself as the manufacturer and sole distributor. Gray-market items are prohibited. The government will consider capability statements from all responsible sources; this is not a request for quotes.

This is a notice of intent to award a sole source contract and is not a request for quotes. The Department of Veterans Affairs on behalf of James J. Peters VA Medical Center, intends award to award a Firm Fixed Price (FFP), sole source action to: Name of Contractor: Stryker Sales, LLC DBA Stryker Endoscopy Street Address: 5900 Optical Court City, State, Zip: San Jose, CA 95138 James J. Peters VAMC has a requirement for an FCC compliant endoscopy surgical system that is compatible with the medical centers existing Stryker equipment. Market research was conducted in accordance with FAR Part 10, and identified the 1688 Stryker Endoscopic Surgical System as capable of meeting the mandatory minimum requirements established by the VA: Camera control unit (CCU) must be both 1080p and 4K compatible within the same console. Must have integrated device control from camera head. Must have shutter lighting automatic adjustment technology built into camera and light source. Light source must have safety feature designed to turn the light off when the cable is disconnected. Must have near-infrared (NIR) illumination for fluorescence imaging using indocyanine green (ICG) and transillumination of the ureters. Must be compatible with existing Stryker arthroscopy cannulas and hardware. In accordance with FAR Part 8.405-6, it has been determined that only one source is reasonably available to meet the minimum salient characteristics and compatibility required; No other systems were identified in the market research phase. Additionally, Stryker Endoscopy has presented themselves as the manufacturer and sole distributor of this system. PRODUCT NUMBER DESCRIPTION 240-099-155 Connected OR Cart 120 V 240031300 Pkg 32IN 4K OLED Surgical Display 240031301 Pkg OLED Display Cover 240300312 SDC4K Base + Device Control + SDP Kit 620050001 Pneumoclear CO2 Conditioning Insufflator Kit Bottle Gas 1688010000 PKG 1688 Camera Control Unit CCU 220230300 PKG L11 LED Light Source with AIM 0240099110K FLAT PANEL ROLL STAND KIT 240031065 Pkg SYNK 4K Wireless Transmitter 240031075 Pkg SYNK 4K Wireless Receiver 240200103 DEVICE CONTROL PACKAGE 1688-610-122 PKG 1688 AIM 4K Camera Head w/Integrated Coupler PC9018 No-Wrap Reprocessing Tray for one 1 Camera Head 233050400 FG SAFELIGHT FIBER OPTIC CABLE WITH AIM 5 MM 233050087 PKG SAFELIGHT HENKE DYONICS STORZ SCOPE ADAPTER 105205295 HOSPITAL POWER CORD 20FT. 620-010-104 FINAL PKG. ASSY CO2 TANK HOSE 620-010-103 TANK YOKE 620-030-503 PKG.CO2 SWITCHING VALVE FOR INSUFFLATOR 0502-938-030 SPY LAPAROSCOPE AUTOCLAVABLE DIA 10mm 30 DEG 33cm 0502-938-010 SPY LAPAROSCOPE AUTOCLAVABLE DIA 10mm 0 DEG 33cm 0502-538-030 SPY LAPAROSCOPE AUTOCLAVABLE DIA 5.4mm 30 DEG 30cm 0502-538-010 SPY LAPAROSCOPE AUTOCLAVABLE DIA 5.4mm 0 DEG 30cm 233032108 PKG LAPAROSCOPE STERILIZATION TRAY 233032116 ENDOSCOPE AND HARDWARE SET TRAY 0351-600-000 PKG. MICRO CART In accordance with Federal Acquisition Regulations (FAR) this notice of intent to sole source with justification to limit sources, satisfies the public posting requirements. Veterans Health Administration prohibits the use of gray market items in their Medical Centers. Gray market items are considered to be items outside of the original equipment manufacturer s intended distribution channels. This notice is not a request for quotes; however, all responsible sources may submit a capability statement which shall be considered by the Government. All capability statements must be received by no later than 12:00 PM Eastern Standard Time on July 14, 2025. Responses to be submitted to Lindsay Goldsmith, Contracting Officer at lindsay.goldsmith@va.gov. A determination by the Government not to compete this proposed contract based on responses to this notice is solely within the discretion of the Government.

From Special Notice posted on Jun 30, 2025

Notice history

1
  1. Special Notice LATEST Posted Jun 30, 2025

Details

Solicitation number 36C24225Q0799
Notice ID 528ac5f061564cf5a18891c0c419c04c
Notice type Special Notice
Product / Service (PSC) 6515
NAICS 339113
Archive date Jul 14, 2025

Award Information

Awardees
0

Documents

1
View on SAM.gov

Contacts

primary
Lindsay Goldsmith

Contracting Officer

Email

Phone

Agency

VETERANS AFFAIRS, DEPARTMENT OF
VETERANS AFFAIRS, DEPARTMENT OF
242-NETWORK CONTRACT OFFICE 02 (36C242)

Place of Performance

Dates

Posted Jun 30, 2025 1 year ago
Last Updated Aug 06, 2026 2 days ago
Due Jul 14, 2025 1 year ago