6515--Modular Knee Positioners For Richmond VAMC 36C24625Q0847

Solicitation 36C24625Q0847 Copied Notice ID 2a0e690add31489a9d0cda7761214773 Copied VETERANS AFFAIRS, DEPARTMENT OF — 246-NETWORK CONTRACTING OFFICE 6 (36C246)
SAM.gov
Posted
Jun 27, 2025
Deadline
Jul 02, 2025
Set-aside
None
NAICS
339112
PSC
6515

Summary

AI-generated · Aug 23, 2025

Modular Knee Positioner required for Richmond VAMC to support orthopedic procedures, particularly total knee arthroplasty. The device must stabilize the leg and allow precise, multi-axis adjustments while maintaining alignment and exposure. Key features include a radiolucent frame mounted to the surgical table rail, high-density padding for soft-tissue protection, multi-point fixation to prevent drift, adjustable thigh/calf/foot cradles, and a quick, tool-free locking system; electronic adjustments via a footswitch or handheld controller; ability to flex 0–135 degrees, abduct/adduct up to 20 degrees, and internally/externally rotate up to 20 degrees; designed for rapid assembly (no more than 2–3 steps) and compatible with sterile draping and intraoperative fluoroscopy at 90-degree knee flexion.

The notice indicates a sole-source award is planned for Innovative Medical Products, Inc. under FAR 13.106-1(b)(2), with no solicitation or competitive quotes being issued. This marks a transition from a market-scan (sources sought) to a targeted procurement, with responses from capable firms invited to demonstrate their ability to meet the requirements; however, the government may choose not to compete. The period of performance is approximately one year. If a respondent believes they can meet the requirements, they should submit evidence of capability for Government consideration.

This Sources Sought Notice is for the Richmond VAMC to determine sources for modular knee positioners listed as the following: Knee Positioner Salient Characteristics What It Is: A Precision Knee Positioner is a specialized surgical device used in orthopedic procedures, particularly total knee arthroplasty (TKA) and other knee surgeries. It is designed to stabilize and manipulate the patient's leg during surgery, providing optimal exposure and consistent positioning of the knee joint. What It Does: Stabilizes the Leg: Secures the leg and maintains consistent alignment throughout the procedure. Allows Controlled Movement: Enables surgeons to flex, extend, rotate, or lock the knee in specific positions to access different anatomical structures with precision. Enhances Surgical Accuracy: Assists in maintaining consistent limb alignment and joint exposure, improving implant placement and surgical outcomes. Improves Efficiency and Ergonomics: Reduces the need for manual holding by surgical staff, minimizing fatigue and allowing for better workflow in the operating room. What It Looks Like: Typically consists of a metal or radiolucent frame mounted to the surgical table. Features adjustable padded supports or cradles to hold the thigh, calf, and foot securely. Includes mechanical arms or hinges that allow for controlled movement of the leg in multiple planes. Some models are equipped with quick-release locks, angle indicators, or motorized components for precision adjustments. The design is compact, sturdy, and often modular to accommodate different patient anatomies and surgical techniques. Physical Characteristics: 1. Soft Tissue Protection The device shall include high-density padding and foam-lined contact surfaces that conform to the patient s anatomy. The device shall include cushioned leg and femoral support specifically designed to distribute weight evenly to reduce the risk of neurovascular compression. 2. Stability The device shall contain a multi-point fixation design. The femoral and distal leg cradles shall be mounted on a rigid base platform that resists lateral movement and rotational drift. The device shall use a non-slip surface interface and clamping to the surgical table rail. 3. Adjustability The device allows for multi-axis adjustability, enabling controlled manipulation of flexion, extension, abduction, adduction, and rotation. Range of motion typically spans: 0° to 135° flexion ±20° abduction/adduction Internal/external rotation up to 20° The device shall make adjustments electronically using a footswitch or handheld controller without manual locking or physical readjustment. 4. Locking Mechanism The positioner shall use a spring-loaded, cam-style locking mechanism that allows for quick engagement and secure hold of the limb at any point along its range of motion. The locking system shall be actuated via a single-hand or foot-activated release. The mechanism shall ensure zero drift once engaged and is designed for tool-free operation. 5. Radiolucency The leg support and cradle system shall be constructed from radiolucent polymer composites, allowing for clear intraoperative fluoroscopic imaging without obstruction. Imaging shall be able to be taken at 90° knee flexion in the axial and lateral planes, and the material composition does not interfere with X-ray or C-arm visibility. 6. Surgical Efficiency The system shall be designed for no more than 2 3 assembly steps. The entire apparatus shall be capable of being affixed to the operating table rail via a universal clamp system, with alignment guides and quick-connect components reducing pre-op configuration time. Thae device shall contain preset angle indicators and sterile draping compatibility. This is a SOURCES SOUGHT announcement only. The purpose of this notice is to conduct market research and obtain information from qualified businesses. This is not a request for bids, quotes, or proposals. All responsible sources must submit a capability statement addressing its capabilities, capacity, and location which shall be considered by the agency. This notice shall not be construed as a commitment by the Government to ultimately award a contract, nor does it restrict the Government to a particular acquisition approach. All information submitted in response to this announcement is voluntary; the Government will not pay for information requested nor will it compensate any respondent for any cost incurred in developing information provided to the Government. Interested parties submitting a response to this inquiry must include the following information: Capability statement Name and address of company NAICS Code SAM.gov UEI number Business size (large, small, VOSB, or SDVOSB) Identify applicable socioeconomic categories and any pertinent information which demonstrates the firm s ability to meet the above requirement. All responses shall be submitted no later than Wednesday, 07/02/2025, by 12:00 PM EST. Responses shall be emailed to: Stephen.Nassan@va.gov. When replying, please include Sources Sought 36C24625Q0847 to ensure the email is reviewed in a timely manner.

From Sources Sought posted on Jun 27, 2025

The Department of Veterans Affairs, Network Contracting Office (NCO) 6, intends to negotiate a sole source contract with INNOVATIVE MEDICAL PRODUCTS, INC. This requirement is for Modular Knee Positioners at the Richmond VAMC, 1201 Broad Rock Blvd, Richmond, VA 23249. The machine must meet the following minimum Salient Characteristics: Knee Positioner Salient Characteristics What It Is: A Precision Knee Positioner is a specialized surgical device used in orthopedic procedures, particularly total knee arthroplasty (TKA) and other knee surgeries. It is designed to stabilize and manipulate the patient's leg during surgery, providing optimal exposure and consistent positioning of the knee joint. What It Does: Stabilizes the Leg: Secures the leg and maintains consistent alignment throughout the procedure. Allows Controlled Movement: Enables surgeons to flex, extend, rotate, or lock the knee in specific positions to access different anatomical structures with precision. Enhances Surgical Accuracy: Assists in maintaining consistent limb alignment and joint exposure, improving implant placement and surgical outcomes. Improves Efficiency and Ergonomics: Reduces the need for manual holding by surgical staff, minimizing fatigue and allowing for better workflow in the operating room. What It Looks Like: Typically consists of a metal or radiolucent frame mounted to the surgical table. Features adjustable padded supports or cradles to hold the thigh, calf, and foot securely. Includes mechanical arms or hinges that allow for controlled movement of the leg in multiple planes. Some models are equipped with quick-release locks, angle indicators, or motorized components for precision adjustments. The design is compact, sturdy, and often modular to accommodate different patient anatomies and surgical techniques. Physical Characteristics: 1. Soft Tissue Protection The device shall include high-density padding and foam-lined contact surfaces that conform to the patient s anatomy. The device shall include cushioned leg and femoral support specifically designed to distribute weight evenly to reduce the risk of neurovascular compression. 2. Stability The device shall contain a multi-point fixation design. The femoral and distal leg cradles shall be mounted on a rigid base platform that resists lateral movement and rotational drift. The device shall use a non-slip surface interface and clamping to the surgical table rail. 3. Adjustability The device allows for multi-axis adjustability, enabling controlled manipulation of flexion, extension, abduction, adduction, and rotation. Range of motion typically spans: 0 to 135 flexion 20 abduction/adduction Internal/external rotation up to 20 The device shall make adjustments electronically using a footswitch or handheld controller without manual locking or physical readjustment. 4. Locking Mechanism The positioner shall use a spring-loaded, cam-style locking mechanism that allows for quick engagement and secure hold of the limb at any point along its range of motion. The locking system shall be actuated via a single-hand or foot-activated release. The mechanism shall ensure zero drift once engaged and is designed for tool-free operation. 5. Radiolucency The leg support and cradle system shall be constructed from radiolucent polymer composites, allowing for clear intraoperative fluoroscopic imaging without obstruction. Imaging shall be able to be taken at 90 knee flexion in the axial and lateral planes, and the material composition does not interfere with X-ray or C-arm visibility. 6. Surgical Efficiency The system shall be designed for no more than 2 3 assembly steps. The entire apparatus shall be capable of being affixed to the operating table rail via a universal clamp system, with alignment guides and quick-connect components reducing pre-op configuration time. Thae device shall contain preset angle indicators and sterile draping compatibility. Period of performance will be for the period 15 October 2024 through 14 October 2025. Justification for this sole source procurement is in accordance with FAR 13.106-1(b)(2) soliciting from a single source. This notice of intent is not a request for competitive quotes. No solicitation documents are available, and telephone requests will not be accepted. However, any business that believes it can meet these requirements may give written notice. Supporting evidence must be furnished in sufficient detail to demonstrate the ability to comply with the above requirement. Responses will be considered by the Government, however, a determination by the Government not to compete the proposed acquisition based upon responses of this notice is solely within the discretion of the Government. NAICS Code 339112/ 1000 employees. Responses received by 12:00 pm est on 7 July 2025 will be considered by the Government. Inquiries shall be emailed to stephen.nassan@va.gov. No telephone request will be accepted.

From Special Notice posted on Jul 02, 2025

Notice history

2
  1. Sources Sought Posted Jun 27, 2025
  2. Special Notice LATEST Posted Jul 02, 2025
    • Title: 6515--Modular Knee Positioners For Richmond VAMC6515--Richmond Modular Knee Positioner
    • Description: Description was updated
    • Notice Type: Sources SoughtSpecial Notice
    • Response Deadline: Jul 02, 2025Jul 07, 2025
    • Set-Aside: NoneNone

Details

Solicitation number 36C24625Q0847
Notice ID 2a0e690add31489a9d0cda7761214773
Notice type Sources Sought
Product / Service (PSC) 6515
NAICS 339112
Place of performance Richmond, VA
Archive date Jul 09, 2025

Award Information

Awardees
0

Documents

1
View on SAM.gov

Contacts

primary
Stephen Nassan

Contracting Specialist

Email

Phone

Agency

VETERANS AFFAIRS, DEPARTMENT OF
VETERANS AFFAIRS, DEPARTMENT OF
246-NETWORK CONTRACTING OFFICE 6 (36C246)

Place of Performance

Richmond VAMC 1201 Broad Rock Blvd
Richmond, VA 23249

Dates

Posted Jun 27, 2025 1 year ago
Last Updated Aug 05, 2026 2 days ago
Due Jul 02, 2025 1 year ago