6515--Dose Calibrator (Brand Name or Equal) 36C25226Q0217
Summary
AI-generated · Jan 21, 2026Provide a brand-name or equal dose calibrator (CRC-55TW with CRC-55TR dos calibrator and Caprac-T wipe test counter, Mirion Capintec model B-5130-2216) for use at a VA hospital, with the following salient capabilities: 8-inch color display or larger; USB PC communications and software updates via USB or flash drive; USB printer capability; plug-and-play chamber; 28 programmable nuclide keys; built-in dose calibration, quality control, and self-diagnostics; memory for 80+ nuclides; automatic chamber QC including linearity; hard-copy data records from an optional printer; 256-channel MCA with detailed spectrum; well counter for wipe tests; user-definable wipe-testing protocols; automated well QC including Chi-Square and MDA; manual and automatic ROI; a preset key for F-18 measurements; and automated Linearity and Geometry testing.
Respondents should demonstrate their ability to supply this equipment, indicate whether they are SDVOSB, VOSB, small or other-than-small firms, and provide capability statements, manufacturer authorization documentation (if applicable), and any required identifiers (such as contract references and tax/UIE information). The information will be used to assess market interest and capacity to support an acquisition at the Edward Hines, Jr. VA Hospital; no telephonic inquiries.
THIS IS A SOURCES SOUGHT NOTICE ONLY. THIS IS NOT A REQUEST FOR QUOTE. The NCO 12, Great Lakes Acquisition Center, 115 S. 84th Street, Suite 101, Milwaukee, WI 53214, is performing market research to determine if there is a sufficient number of qualified: (1) Service-Disabled Veteran Owned Small Business (SDVOSB); (2) Veteran Owned Small Business (VOSB); or (3) Small or emerging small business firms, or (4) Other Than Small business firms, to provide a Brand Name or Equal Dose Calibrator to the Edward Hines, Jr. VA Hospital 5000 South 5th Avenue Hines, IL 60141-5000. Brand Name DESCRIPTION OF SUPPLIES Manufacturer Manufacturer Part No QTY CRC-55TW with a CRC-55TR DOS CALIBRATOR AND CAPRAC-T WIPE TEST COUNTER Mirion Technologies (Capintec) B-5130-2216 1 General Requirements: Salient Characteristics: (Equal) 8 in. color display or larger Must have USB/PC Communications Must have the ability to upgrade software via USB or flash drive USB printer capability Chamber plug and play capability 28 programmable nuclide keys Built-in dose calibration, quality control and self diagnostics Must have over 80 nuclides in memory Must have automatic chamber QC including linearity Hard copy records of data available from optional printer Must have 256 channel MCA with detailed spectrum for identification analysis Well counter for wipe tests User-definable protocols for wipe testing Automated well QC including Chi-Square and MDA Manual and automatic ROI Must include a pre-set key for F-18 measurements Automated Linearity and Geometry testing All interested firms who can meet the requirements stated above should respond, in writing, INCLUDING ALL THE FOLLOWING: Company name. Address. Point of contact (name/title/telephone number/e-mail address). FSS / SEWP Contract number, if applicable. UIE number. Tax ID number. Indication of which business category (SDVOSB, VOSB, Small Business or Other Than Small Business) for which the organization qualifies. A capability statement that addresses the organizations qualifications and ability to provide the requirement depicted above. Documentation from manufacturer (i.e. correspondence from manufacturer) of your firm being an authorized distributor for the manufacturer. Submit responses to the Contracting Specialist, Waymon McNeal, at Waymon.McNealjr@va.gov no later than 3:00 PM (Central Standard Time), 27 January 2026. 36C25226Q0217 Dose Calibrator shall be referenced on all correspondence regarding this announcement. TELEPHONIC INQUIRIES WILL NOT BE ACCEPTED. The NAICS Code 339112 Surgical and Medical Instrument Manufacturing is applicable to this acquisition; the size standard is 1000 employees. Interested firms are reminded that in accordance with FAR 4.12, prospective contractors shall complete electronic annual representations and certifications in conjunction with FAR 4.11 required registration in the Systems for Award Management (SAM) database prior to award of a contract. The Government will use responses to this notice to make an appropriate acquisition decision. This is the only notice; no other copies of this notice will be provided.
From Sources Sought posted on Jan 20, 2026Presolicitation Notice Presolicitation Notice Page 3 of 3 Presolicitation Notice The VA Great Lakes Acquisition Center intends to solicit a Brand Name or Equal Dose Calibrator to the Edward Hines, Jr. VA Hospital 5000 South 5th Avenue Hines, IL 60141-5000. This procurement is being conducted in accordance with FAR Part 12, 13, and 19. Contract will be firm fixed price and the corresponding NAICS Code 339112. This will be a Small Business set-aside solicitation. Please see Request for Quote (RFQ) document 36C25226Q0217 for details in the near future. This RFQ will be posted on or around Wednesday, February 18, 2026. Offers will be due no later than 15:00 Central Time, Chicago, USA on Wednesday, February 25, 2026. Brand Name DESCRIPTION OF SUPPLIES Manufacturer Part No QTY CRC-55TW with a CRC-55TR DOS CALIBRATOR AND CAPRAC-T WIPE TEST COUNTER Mirion Technologies (Capintec) B-5130-2216 1 Equal Requirements: Salient Characteristics: 8 in. color display or larger Must have USB/PC Communications Must have the ability to upgrade software via USB or flash drive USB printer capability Chamber plug and play capability 28 programmable nuclide keys Built-in dose calibration, quality control and self diagnostics Must have over 80 nuclides in memory Must have automatic chamber QC including linearity Hard copy records of data available from optional printer Must have 256 channel MCA with detailed spectrum for identification analysis Well counter for wipe tests User-definable protocols for wipe testing Automated well QC including Chi-Square and MDA Manual and automatic ROI Must include a pre-set key for F-18 measurements Automated Linearity and Geometry testing
From Presolicitation posted on Feb 18, 2026Dose Calibrator
From Solicitation posted on Feb 18, 2026Notice history
3-
-
Presolicitation Posted Feb 18, 2026View changes (5)
- Title: 6515--Dose Calibrator Brand Name or Equal → 6515--Dose Calibrator (Brand Name or Equal)
- Description: Description was updated
- Notice Type: Sources Sought → Presolicitation
- Response Deadline: Jan 27, 2026 → Feb 25, 2026
- Set-Aside: None → Total Small Business Set-Aside (FAR 19.5)
-
Solicitation LATEST Posted Feb 18, 2026View changes (3)
- Description: Description was updated
- Notice Type: Presolicitation → Solicitation
- Set-Aside: Total Small Business Set-Aside (FAR 19.5) → None
Details
Award Information
Contacts
Contract Specialist