Contacts, documents and full notice history are available with a subscription.
Award Notice 3 notices 1 document

6515--Consignment Agreement - Prosthetic Valves - Ann Arbor 36C25025Q0684

Solicitation 36C25025Q0684 Copied Notice ID 08ad532a214e429f8013457da3319ab6 Copied VETERANS AFFAIRS, DEPARTMENT OF — 250-NETWORK CONTRACT OFFICE 10 (36C250)
SAM.gov
Posted
Jul 10, 2025
Deadline
Jul 14, 2025
Set-aside
None
NAICS
339113
PSC
6515

Summary

AI-generated · Aug 24, 2025

A sole-source, consignment procurement is being planned with Edwards Lifesciences LLC to supply a defined catalog of implantable heart valve devices and related annuloplasty products for use at the VA Ann Arbor facility. The items include various Edwards Lifesciences prosthetic valves and annuloplasty systems intended for short-shelf-life storage on-site, enabling on-hand availability to match patient needs during procedures.

The arrangement would be a firm-fixed-price contract with a five-year ordering period, using a consignment model so the VA holds inventory until it is used. Edwards Lifesciences is identified as the only capable source to meet the requirements, and no solicitation package is available. Any response must show clear and convincing evidence that competition would be advantageous to the Government.

Notice of Intent to Sole Source Requirement The Department of Veterans Affairs, VA Ann Arbor Healthcare System, NCO 10 Contracting Activity intends to negotiate a sole source contract under Simplified Acquisition Procedures and the authority of FAR 13.106-1(b)(2), Soliciting from a single source for the following items listed below. The associated NAICS code for this is 339113. The vendor will be Edwards Lifesciences LLC, 1 Edwards Way, Irvine, CA 92614. Description of requirements: Consignment contract for the following items: INSPIRIS RESILIA AORTIC VALVE (19MM, 21MM, 23MM, 25MM, 27MM, 29 MM) PHYSIO MITRAL ANNULOPLASTY RING (24M, 26M, 28M, 30M, 32M, 34M, 36M, 38M, 40M) COSGROVE ANNULOPLASTY SYSTEM (26MM, 28MM, 30MM, 32MM, 34MM, 36MM, 38MM) MC3 TRICUSPID ANNULOPLASTY SYSTEM (26T, 28T, 30T, 32T, 34T, 36T) MITRIS RESILIA MITRAL VALVE (25MM, 27MM, 29MM, 31MM, 33MM) MAGNA MITRAL EASE PERICARDIAL VALVE WITH THERMAFIX (25MM, 27MM, 29MM, 31MM, 33MM) In the marketplace for implantable heart valves there are two main types: mechanical and bioprosthetic. For the majority of patients, age is the critical factor, with bioprosthetic being recommended for patients over the age of 65. While each patient is given individual attention and care when choosing which valve replacement option is best for them, Edwards Lifesciences has typically been the most requested bioprosthetic valve by both patients and surgeons. Edwards Lifesciences also has a more robust product line to include mitral valves, tricuspid annuloplasty systems, annuloplasty rings, etc., which have also been requested by our physicians. The Edwards Lifesciences product storage is also recommended vs other competitors, where their ability for dry storage tends to be optimal compared to the cold storage of most other bioprosthetic heart valves. Edwards Lifesciences LLC heart valves are specific because the INSPIRIS Magna Ease uses the INSPIRIS design, it is an internally mounted pericardial tissue using 3 leaflets that are each individually cut. They have a 2 stage anti-calcification process addressing both phospholipids and residual glutaraldehyde. The 7300TFX uses a dual stage anti-calcificationepic. The 4900 features a specific 3d semi-rigid design that has been specifically designed for the Tricuspid position. The 4600 Cosgrove comes pre sized and does not need to be cut and it can be used in Mitral and Tricuspid position. The Physio uses 4 individual elgiloy bands to preserve natural annular movement and shape of the annulus. Consignment contracts allow the VA to keep several of these short shelf-life items in the facility without having to buy them until they are used. The items requested meet the strict requirements of quality and functionality for the procedures for which they are chosen. The supplies are selected based on their specific use during procedures. Edwards Lifesciences, LLC is the only firm capable of providing the supplies. The VA Ann Arbor Healthcare System has several different consignment instruments put in place for flexibility and added variety of sizes and models that allow the VA physicians the ability to make the best match possible of implantable device to the veteran s health need. A firm fixed price requirements contract with a 5-year ordering period is anticipated and shall be awarded. It is the Government's belief that only the proposed candidate possesses the required capabilities to successfully meet this requirement. It is the Government's intention to solicit and negotiate with only this source. This notice of intent is not a request for competitive proposals. It is not a solicitation or request for offers. No solicitation package is available. Any response to this notice must show clear and convincing evidence that competition would be advantageous to the Government. Responses must be received no later than 4:30 pm on Monday, July 14, 2025. Kellie Konopinski Contracting Officer (734) 222-4330 Kellie.Konopinski@va.gov

From Special Notice posted on Jul 10, 2025

VHAPG Part 813.5 Simplified Acquisition Procedures for Certain Commercial Items Attachment 1: Request for Sole Source Justification Template >SAT-$7.5M under FAR13.5 Effective Date: 11/15/24 Page 1 of 9 REVISION: 01 Acquisition ID#: 36C250-25-AP-3827 DEPARTMENT OF VETERANS AFFAIRS SOLE SOURCE JUSTIFICATION UNDER SIMPLIFIED PROCEDURES FOR CERTAIN COMMERCIAL ITEMS IN ACCORDANCE WITH FAR 13.5 Acquisition Plan Action ID: 36C250-25-AP-3827 Contracting Activity: Department of Veterans Affairs, NCO 10, 24 Frank Lloyd Wright Drive, Suite M2200, Ann Arbor, MI 48105 in support of LTC Charles S. Kettles VA Medical Center, 2215 Fuller Road, Ann Arbor, MI 48105. 2237: 506-25-3-1022-0044. Nature and/or Description of the Action Being Processed: This is an individual justification to support a new firm-fixed price, 5-year ordering period IDIQ requirements contract with Edwards Lifesciences LLC for an assortment of different sized Inspiris Resilia Aortic Valves, Physio Mitral Annuloplasty Ring, Tricuspid Annuloplasty System, MC3 Tricuspid Annuloplasty System, Perimount Plus Pericardial Mitral Bioprosthesis with Tricentrix Holder with Thermafix, and Magna Mitral Ease Pericardial Valve with Thermafix for various scheduled and emergent procedures at the LTC Charles S. Kettles VA Medical Center. These items must be stocked in the Operating Room/Surgery Service Department or available just-in-time at all times; therefore, a consignment agreement will be established against the IDIQ as the method of delivery. The contractor, Edward Lifesciences LLC, will be responsible for maintaining the agreed to inventory levels and will retain ownership of the material until the VA uses an item, at which time, the VA will make payment for the used item. The procurement will be completed in accordance with FAR 13.5 Simplified Procedures for Certain Commercial Items and specifically FAR 13.501 Special Documentation Requirements, where acquisitions conducted under Simplified Acquisition Procedures are exempt from the requirements of FAR Part 6, but still require a justification using the format of FAR 6.303-2. Description of Supplies/Services Required to Meet the Agency s Needs: The proposed IDIQ contract is for different sized Inspiris Resilia Aortic Valves, Physio Mitral Annuloplasty Ring, Tricuspid Annuloplasty System, MC3 Tricuspid Annuloplasty System, Perimount Plus Pericardial Mitral Bioprosthesis with Tricentrix Holder with Thermafix, and Magna Mitral Ease Pericardial Valve with Thermafix for various scheduled and emergent procedures. Therefore, these items must be stocked in the Operating Room/Surgery Service Department or available just-in-time at all times and will utilize a consignment agreement as the delivery method. The exact sizes and/or models are not always known prior to the surgical procedure. Availability of an array of non-biological implant inventory at any given moment increases timely access to quality patient care. Proposed period of performance will include a 5-year ordering period. Period of Performance: 9/30/2025 9/29/2030. Description Part Number Estimated Yearly Usage Unit 1 Inspiris Resilia Aortic Valve, 19mm 11500A19 2 EA 2 Inspiris Resilia Aortic Valve, 21mm 11500A21 2 EA 3 Inspiris Resilia Aortic Valve, 23mm 11500A23 2 EA 4 Inspiris Resilia Aortic Valve, 25mm 11500A25 2 EA 5 Inspiris Resilia Aortic Valve, 27mm 11500A27 2 EA 6 Inspiris Resilia Aortic Valve, 29mm 11500A29 2 EA 7 Physio Mitral Annuloplasty Ring 24M 4450M24 2 EA 8 Physio Mitral Annuloplasty Ring 26M 4450M26 2 EA 9 Physio Mitral Annuloplasty Ring 28M 4450M28 2 EA 10 Physio Mitral Annuloplasty Ring 30M 4450M30 2 EA 11 Physio Mitral Annuloplasty Ring 32M 4450M32 1 EA 12 Physio Mitral Annuloplasty Ring 34M 4450M34 1 EA 13 Physio Mitral Annuloplasty Ring 36M 4450M36 1 EA 14 Physio Mitral Annuloplasty Ring 38M 4450M38 1 EA 15 Physio Mitral Annuloplasty Ring 40M 4450M40 1 EA 16 Cosgrove Annuloplasty System 26MM 460026MM 2 EA 17 Cosgrove Annuloplasty System 28MM 460028MM 2 EA 18 Cosgrove Annuloplasty System 30MM 460030MM 2 EA 19 Cosgrove Annuloplasty System 32MM 460032MM 2 EA 20 Cosgrove Annuloplasty System 34MM 460034MM 1 EA 21 Cosgrove Annuloplasty System 36MM 460036MM 1 EA 22 Cosgrove Annuloplasty System 38MM 460038MM 1 EA 23 MC3 Tricuspid Annuloplasty System 26T 4900T26 1 EA 24 MC3 Tricuspid Annuloplasty System 28T 4900T28 1 EA 25 MC3 Tricuspid Annuloplasty System 30T 4900T30 1 EA 26 MC3 Tricuspid Annuloplasty System 32T 4900T32 1 EA 27 MC3 Tricuspid Annuloplasty System 34T 4900T34 1 EA 28 MC3 Tricuspid Annuloplasty System 36T 4900T36 1 EA 29 Magna Mitral Ease Pericardial Valve with ThermaFix 25MM 7300TFX25 2 EA 30 Magna Mitral Ease Pericardial Valve with ThermaFix 27MM 7300TFX27 2 EA 31 Magna Mitral Ease Pericardial Valve with ThermaFix 29MM 7300TFX29 2 EA 32 Magna Mitral Ease Pericardial Valve with ThermaFix 31MM 7300TFX31 1 EA 33 Magna Mitral Ease Pericardial Valve with ThermaFix 33MM 7300TFX33 1 EA 34 MITRIS RESILIA Mitral Valve, 25MM 11400M25 1 EA 35 MITRIS RESILIA Mitral Valve, 27MM 11400M27 1 EA 36 MITRIS RESILIA Mitral Valve, 29MM 11400M29 1 EA 37 MITRIS RESILIA Mitral Valve, 31MM 11400M31 1 EA 38 MITRIS RESILIA Mitral Valve, 33MM 11400M33 1 EA Statutory Authority Permitting Restricted Competition: FAR 13.5 Simplified Procedures for Certain Commercial Items. The statutory authority for applying the Simplified Procedures for Commercial Items of FAR 13.5 is 41 U.S.C. 1901 and is implemented by FAR 13.106-1(b)(2) for restricting competition on this procurement. Competition is restricted on this procurement for the reason below: ( X ) Only One Responsible Source and No Other Supplies or Services Will Satisfy Agency Requirements ( ) Unusual and Compelling Urgency ( ) Industrial Mobilization, Engineering, Developmental or Research Capability or Expert Services ( ) International Agreement ( ) Authorized or Required by Statute ( ) National Security ( ) Public Interest Demonstration that the Contractor s Unique Qualifications or Nature of the Acquisition Requires the Use of the Authority Cited Above (applicability of authority): Only one responsible source. In the marketplace for implantable heart valves there are two main types: mechanical and bioprosthetic. For the majority of patients, age is the critical factor, with bioprosthetic being recommended for patients over the age of 65. While each patient is given individual attention and care when choosing which valve replacement option is best for them, Edwards Lifesciences has typically been the most requested bioprosthetic valve by both patients and surgeons. Edwards Lifesciences also has a more robust product line to include mitral valves, tricuspid annuloplasty systems, annuloplasty rings, etc., which have also been requested by our physicians. The Edwards Lifesciences product storage is also recommended vs other competitors, where their ability for dry storage tends to be optimal compared to the cold storage of most other bioprosthetic heart valves. Edwards Lifesciences LLC heart valves are specific because the INSPIRIS Magna Ease uses the INSPIRIS design, it is an internally mounted pericardial tissue using 3 leaflets that are each individually cut. They have a 2 stage anti-calcification process addressing both phospholipids and residual glutaraldehyde. The 7300TFX uses a dual stage anti-calcificationepic. The 4900 features a specific 3d semi-rigid design that has been specifically designed for the Tricuspid position. The 4600 Cosgrove comes pre sized and does not need to be cut and it can be used in Mitral and Tricuspid position. The Physio uses 4 individual elgiloy bands to preserve natural annular movement and shape of the annulus. Consignment contracts allow the VA to keep several of these short shelf-life items in the facility without having to buy them until they are used. The items requested meet the strict requirements of quality and functionality for the procedures for which they are chosen. The supplies are selected based on their specific use during procedures. Edwards Lifesciences, LLC is the only firm capable of providing the supplies and services described in Section III above. The VA Ann Arbor Healthcare System has several different consignment instruments put in place for flexibility and added variety of sizes and models that allow the VA physicians the ability to make the best match possible of implantable device to the veteran s health need. Description of Efforts Made to ensure that offers are solicited from as many potential sources as deemed practicable: An Intent to Sole Source will be posted to Contract Opportunities prior to award to confirm there are no other sources. Determination by the CO that the Anticipated Cost to the Government will be Fair and Reasonable: The Contracting Officer will use the price analysis technique in FAR 13.106-3(a)(2)(ii), comparison of the proposed price with prices found reasonable on previous purchases, and any other techniques necessary to determine the prices to be fair and reasonable. Description of the Market Research Conducted and the Results, or a Statement of the Reasons Market Research Was Not Conducted: In accordance with FAR Part 10 and VAAR 810, market research has been conducted for this acquisition. VetCert was searched under NAICS 339113 and 932 concerns were found. DSBS was searched under NAICS 339113 and keyword heart valve consignment and no results were found. Searched SAM under heart valve consignment agreement . There were 21 results. Edwards Lifesciences, Abbott Laboratories, Medtronic, St. Jude, and ATS Medical. All are Large Businesses. Searched NAC under Heart Valve and no results were found. Searched SCMC under consignment and refined with heart valve and one result was found from Abbott Laboratories. Searched GSA advantage under consignment and refined with heart valve and no results were found. Searched FPDS under heart valve consignment and several results were found: Edwards Lifesciences, Medtronic Inc., Carbiomedics, Inc., St. Jude medical Inc., and Cryolife, Inc. Seared MSPV and Edwards Lifesciences is not a Prime Vendor. The Interagency Contract Directory was searched under consignment, Edwards Lifesciences, and heart valves and 3 results were found for consignment contracts in other NCO s. Category Management Quick Decisions Dashboard was searched under heart valve consignment with no results. Searched Defense Logistics Agency Electronic Catalog (ECAT) using keyword heart valve consignment with no results. FDA was searched under Edwards Heart Valves and several items were found. The market for prosthetic heart valves is regulated mainly by which devices are FDA approved. As such, several name brands, such as Perimount, Mosaic/Hancock, Biocor/Epic, MitroFlow/Crown, Soprano, and Trifecta, are available on the market. As these devices are typically placed during a complex and life-altering surgery, the specific valve is usually chosen by the patient with input from the surgeon. Therefore, the expert opinion of the surgeons is of utmost importance when choosing which specific brand a hospital should choose. Their recommendation has been to stay with Edwards Lifesciences LLC. A consignment contract allows the facility to have a full variety of devices on hand for immediate use, while cost is deferred until the device is surgically placed. Edwards Lifesciences LLC is a large business and they have no distributors for consignment contracts. Therefore, the VA Rule of Two and the SBA Rule of Two cannot be met. The products are manufactured in US, Singapore and Costa Rica. A non-availability determination and a Buy American Act waiver are not required as the procurement will be completed under the authority of 38 U.S.C. 8123. Any Other Facts Supporting the Use of Other than Full and Open Competition: There are no other supporting facts. Listing of Sources that Expressed, in Writing, an Interest in the Acquisition: Edwards Lifesciences LLC, 1 Edwards Way, Irvine, CA 92614. A Statement of the Actions, if any, the Agency May Take to Remove or Overcome any Barriers to Competition before Making subsequent acquisitions for the supplies or services required: Should a requirement of this nature recur, the market will again be surveyed.

From Justification posted on Sep 29, 2025

Notice history

3
  1. Special Notice Posted Jul 10, 2025
  2. Justification Posted Sep 29, 2025
    • Title: 6515--Consignment Agreement - Prosthetic Valves - Ann Arbor6515--Consignment - Prosthetic Valves - Ann Arbor
    • Description: Description was updated
    • Notice Type: Special NoticeJustification
    • Response Deadline: Jul 14, 2025Not set
  3. Award Notice LATEST Posted Sep 29, 2025

Details

Solicitation number 36C25025Q0684
Notice ID 08ad532a214e429f8013457da3319ab6
Award number 36C25025D0076
Notice type Special Notice
Product / Service (PSC) 6515
NAICS 339113
Archive date Oct 21, 2025

Award Information

Awardee
1
Award Date
Sep 29, 2025

Awardees

Company Name UEI CAGE Code Location
Edwards Lifesciences LLC MR4FCKSNGRC1 1PYT9 IRVINE

Documents

1
View on SAM.gov

Contacts

primary
Kellie Konopinski

Contracting Officer

Email

Phone

Agency

VETERANS AFFAIRS, DEPARTMENT OF
VETERANS AFFAIRS, DEPARTMENT OF
250-NETWORK CONTRACT OFFICE 10 (36C250)

Place of Performance

Dates

Posted Jul 10, 2025 1 year ago
Last Updated Aug 06, 2026 2 days ago
Due Jul 14, 2025 1 year ago