6515--CAPTUS 4000e THYROID UPTAKE SYSTEM_BRAND NAME ONLY 100% SDVOSB SET-ASIDE 36C24126Q0293
Summary
AI-generated · Mar 09, 2026Procure one Captus 4000e Thyroid Uptake System (brand-name only) for the VA Maine Healthcare System, including: a 20" all-in-one color touchscreen computer, articulating arm, medical-grade counter top and storage, 1" lead-shielded well detector, integrated DICOM interface software, custom protocol software, ergonomic mobile stand, and all required hardware, accessories, and manuals. Include one neck phantom for thyroid uptake measurements. The system must provide a fully integrated DICOM interface to communicate with the hospital information system, and on-site training must be provided to medical staff.
Deliver within 90 days of award; on-site training to be completed within 2 weeks after installation. Equipment must be new (not refurbished), with a minimum one-year warranty and ongoing technical support plus spare parts/consumables availability for at least seven years after delivery. The contractor must have experience supplying, installing, and training users on similar thyroid uptake/nuclear medicine systems for VA hospitals or other major healthcare facilities.
STATEMENT OF WORK For Procurement of Captus 4000e Thyroid Uptake System For VA Maine Healthcare System (Togus) 1. Background The VA Maine Healthcare System (Togus) requires a comprehensive Nuclear Medicine Measurement System for thyroid uptake measurements, bioassays, wipe tests, quality control testing, and other related functions in the Nuclear Medicine department. 2. Objectives The primary objectives of this procurement are: 2.1 To acquire the Captus 4000e Thyroid Uptake System made by Mirion/Capintec with integrated DICOM interface, custom protocol capabilities, automated QA testing, and ergonomic mobile stand. 2.2 To enable accurate thyroid uptake measurements, wipe tests, and quality control processes for radiopharmaceuticals used in diagnostic imaging procedures. 2.3 To interface the system directly with the hospital information systems for transfer of patient data, test results and QC records. 3. Description of Requirements 3.1 The contractor shall provide one (1) Captus 4000e Thyroid Uptake System (Part # 5430-30152) including: - 20" all-in-one color touchscreen computer - Articulating arm with wide range of motion - Medical grade counter top and storage shelf - 1" lead shielded well detector - Integrated DICOM interface software - Custom protocol software - Ergonomic mobile stand - All required hardware, accessories and manuals 3.2 The system shall have a fully integrated DICOM interface (Part # 5430-00007) to communicate and transfer data with the VA's hospital information systems. 3.3 One (1) Neck Phantom (Part # 5230-0038) for thyroid uptake measurements shall be provided. 3.4 The contractor shall provide on-site training to medical staff on proper operation and use of the system. 4. Deliverables and Schedule 4.1 All equipment and components specified in Section 3 shall be delivered within 90 days after award. 4.2 On-site training shall be completed within 2 weeks after installation. 5. Other Requirements 5.1 All equipment shall be new and not refurbished, remanufactured or discontinued models. 5.2 The contractor shall provide a minimum 1 year warranty on the entire system. 5.3 The contractor shall provide technical support and availability of spare parts/consumables for at least 7 years after delivery. 6. Qualifications The contractor shall have experience in supplying, installing and providing training for similar thyroid uptake/nuclear medicine systems to VA hospitals or other major healthcare facilities. END OF STATEMENT OF WORK
From Combined Synopsis/Solicitation posted on Mar 06, 2026RESPONSE TO VENDOR QUESTIONS The purpose of this amendment is to answer vendor questions: Would you please confirm which delivery requirement governs for this procurement? Answer: All equipment and components specified shall be delivered within 90 days after award. Is there a loading dock available for delivery at that location, or should vendors assume liftgate service will be required? Answer: There is a fully operational warehouse with liftgate available.
From Combined Synopsis/Solicitation posted on Mar 23, 2026Notice history
2-
-
Combined Synopsis/Solicitation LATEST Posted Mar 23, 2026View changes (2)
- Title: 6515--CAPTUS 4000e THYROID UPTAKE SYSTEM - BRAND NAME ONLY 100% SDVOSB SET-ASIDE → 6515--CAPTUS 4000e THYROID UPTAKE SYSTEM_BRAND NAME ONLY 100% SDVOSB SET-ASIDE
- Description: Description was updated
Details
Award Information
Contacts
Contracting Office
Phone
Agency
Place of Performance
1 VA Center
Augusta, ME 04330-6796
USA