Contacts, documents and full notice history are available with a subscription.
Special Notice Expired 1 notice 1 document

6515--Bronchoscopes Intent to Sole Source 36C24826Q0372

Solicitation 36C24826Q0372 Copied Notice ID 61c4498e11c245cd9cb2b1604969e33a Copied VETERANS AFFAIRS, DEPARTMENT OF — 248-NETWORK CONTRACT OFFICE 8 (36C248)
SAM.gov
Posted
Feb 26, 2026
Deadline
Mar 12, 2026
Set-aside
None
NAICS
339112
PSC
6515

Summary

AI-generated · Feb 27, 2026

Upgrade to Olympus BF-UC190-A ultrasound bronchoscopes to replace end-of-life BF-UC180F scopes at James A. Haley Veterans Hospital. Olympus America Inc. is the sole source and OEM; no distributors; all sales and upgrades must come directly from Olympus. The Buy American Act is not applicable.

Must be brand-name only and fully compatible with the current Olympus video processing system and existing reprocessing equipment. Key features include real-time ultrasound imaging with ViziShot 2 TBNA needle visualization, integrated water jet, compact distal tip with enhanced maneuverability for difficult-to-reach lymph nodes, 20-degree forward oblique angle, Dual Focus, higher-resolution imaging, and a 2.2 mm working channel compatible with Olympus EBUS-TBNA needles. Software compatibility with EndoSoft/ProvationMD and CPRS/Vista; training not required; standard manufacturer warranty (no extended warranty). Delivery and installation within 30 days of purchase order to James A. Haley VA Hospital, Tampa; trade-in value for BF-UC180F units on hand; not a competitive solicitation, with potential consideration of a competitive procurement based on responses.

NOTICE OF INTENT TO SOLE SOURCE The Department of Veterans Affairs (VA) hereby provides notice of its intent to award a sole-source, firm-fixed-price contract to Olympus America Inc. for an upgrade to an existing Olympus bronchoscopic system currently in use by the Government. The Bronchoscopes are manufactured in Japan a TAA-designated country. The Buy American Act is not applicable to this procurement. Olympus America Inc. is the Original Equipment Manufacturer (OEM) and has confirmed that they do not have any authorized distributors. All sales, upgrades, and replacements for this system must be provided directly by Olympus. Therefore, this represents a sole source requirement under FAR 6.302 1 (Only One Responsible Source). The Contracting Officer does not wish to receive phone calls regarding this requirement. Interested parties may identify their interest and capability to respond only via email. Responses must be submitted by email to Marcus.Lewis2@va.gov no later than March 12, 2026, 10:00 am. Any responses received will be evaluated solely to determine whether to conduct competitive procurement. This is not a request for competitive proposals and a solicitation will not be issued. However, all information received by the response deadline will be considered by the Government. STATEMENT OF NEED GENERAL: The Bronchoscopy Section Pulmonary Department of Medicine Services at James A. Haley Veterans Hospital, 13000 Bruce B. Downs Blvd, Tampa, Florida 33612, has a requirement for replacement Olympus BF-UC190-A ultrasound bronchoscopes. BACKGROUND: The Bronchoscopy Section Pulmonary Department of Medicine Services at James A. Haley Veterans Hospital, 13000 Bruce B. Downs Blvd, Tampa, Florida 33612, has a requirement for replacement Olympus BF-UC190-A ultrasound bronchoscopes. The currently used BF-UC180F ultrasound bronchoscopes are at end-of-life, and Olympus is coming to an end to their support of this model. PURPOSE: These scopes are used in the Bronchoscopy procedure rooms to provide video imaging during bronchoscopy procedures. SCOPE: James A. Haley VA Hospital is requesting contractors provide brand name only equipment that meets the physical, functional and performance of the listed salient characteristics in this section. The equipment features are essential to the technical requirements to meet the needs of the government. SALIENT CHARACTERISTICS: Must be compatible with current video processing system (Olympus) used in all suites Must be able to be cleaned and reprocessed using the current equipment owned by SPS Provides enhanced access and control to allow staging and diagnosis of even difficult-to-reach lymph nodes and lesions. Real-time ultrasound imaging enables direct visualization of the ViziShot 2 EBUS-TBNA needle as it penetrates the lymph node. This facilitates correct capsule-to-capsule technique, which helps to optimize sample collection, and provides clearer procedural views: an integrated water jet channel helps maintain clear views during procedures The uniquely designed compact distal tip of the BF-UC190F and increased scope angulation enhances maneuverability with better access to difficult-to-reach lymph node stations in the mediastinum (4L) and in the hilum (10R). A decreased forward oblique angle of 20 facilitates easier endoscopic orientation and allows the operator to keep the endoscopic image in full field of view while navigating the airways during a procedure. Dual Focus allows the user to select between two focus settings. A steeper needle puncture angle provides a more perpendicular needle orientation toward the target allowing for smoother target penetration between cartilage rings and other critical vessels. An improved endoscopic image with higher resolution provides better visualization in the airway to accurately identify anatomy landmarks and detect abnormalities. Wider/Increased Viewable Angle: Wider the field of view to attain an increase viewable distance. The power of the EVIS EXERA III platform expands across the hospital to enable equipment standardization and simplified support and service, with the ultimate goal of lowering the total cost of equipment. The BF-UC190F has a working channel of 2.2 mm that is compatible with a full line-up of Olympus EBUS-TBNA needles which are designed to deliver outstanding performance while minimizing channel damage, thereby potentially reducing repair costs and extending endoscope life. TRADE: Trade-in value will be provided in for Olympus BF-UC180F ultrasound bronchoscopes currently on hand. Serial Numbers as follows: 7621602; 7621606; 7621611; 7621612. SOFTWARE: Compatibility with EndoSoft/ProvationMD softwares, and CPRS/Vista. TRAINING: Government will not require additional training. WARRANTY OF EQUIPMENT: Government requirement for standard manufacturer industry warranty term. Government does not accept extended warranty, which requires advance payment. DELIVERY SCHEDULE: All items to be delivered and installed within 30 days of receipt of purchase order, and no later than 4/30/2026. PLACE OF Delivery: James A. Haley Veterans Hospital, 13000 Bruce B. Downs Blvd. Bldg 1, Tampa, Florida 33612, between 8:00AM to 4:30PM. Delivery during the Holiday will not be accepted.

From Special Notice posted on Feb 26, 2026

Notice history

1
  1. Special Notice LATEST Posted Feb 26, 2026 View

Details

Solicitation number 36C24826Q0372
Notice ID 61c4498e11c245cd9cb2b1604969e33a
Notice type Special Notice
Product / Service (PSC) 6515
NAICS 339112
Archive date Apr 06, 2026

Award Information

Awardees
0

Documents

1
View on SAM.gov

Contacts

primary
Marcus Lewis

Contracting Officer

Email

Phone

Agency

VETERANS AFFAIRS, DEPARTMENT OF
VETERANS AFFAIRS, DEPARTMENT OF
248-NETWORK CONTRACT OFFICE 8 (36C248)

Place of Performance

Dates

Posted Feb 26, 2026 5 months ago
Last Updated Aug 06, 2026 1 day ago
Due Mar 12, 2026 4 months ago