Contacts, documents and full notice history are available with a subscription.
Sources Sought Expired 1 notice 1 document

6515--ACIST CVi Contrast Dye Injector System 36C25926Q0221

Solicitation 36C25926Q0221 Copied Notice ID 45e3ce3236f244879f522c5b0fe36a18 Copied VETERANS AFFAIRS, DEPARTMENT OF — NETWORK CONTRACT OFFICE 19 (36C259)
SAM.gov
Posted
Jan 30, 2026
Deadline
Feb 06, 2026
Set-aside
None
NAICS
339112
PSC
6515

Summary

AI-generated · Jan 31, 2026

Market research to identify sources capable of providing an ACIST CVi Contrast Dye Injector System (brand name or equal) for the Rocky Mountain Regional VA Medical Center. This is not a solicitation or commitment; information is requested solely to assess market interest, capability, and supplier classification. Key requirements include must-meet features such as multi-use syringe operation, power options of 100–120 VAC or 200–240 VAC, real-time dose tracking, a hand controller with variable rate technology, options for smaller catheters, air-injection mitigation design elements, air column detection, and a manifold to prevent reverse flow; automatic hemodynamic monitoring; configurable contrast and saline flow rates; injection modes for Cardiac and Peripheral Vascular applications; pressure limits from 200 to 1200 psi; capability to support up to six patient cases per syringe; and single or dual pressure monitoring. The purchase must include a warranty for the life of the equipment from installation, plus OEM-certified preventive maintenance (annual calibration, software/firmware updates, filter checks, pressure sensor verification, safety and grounding checks, emergency shutoff verification) and as-needed OEM repair services.

Responses should provide: company name and address, primary point of contact (name, email, phone), SAM.gov UEI, whether on GSA/FSS or VA contract, whether manufactured in the USA, and applicable small-business program eligibility. Indicate if you are a small business and/or a US manufacturer, ownership/possession of the item by your personnel or facilities, and whether you will supply the end item from a small U.S. manufacturer or obtain a waiver if applicable. If possible, include specifications, cut sheets, capability statements, and past experience to demonstrate the ability to meet these requirements. Responses are for market research only and do not constitute a bid or contract.

The Department of Veterans Affairs, Veterans Health Administration (VHA), Network Contracting Office 19 (NCO 19) is conducting a market survey and is seeking potential sources for ACIST CVi Contrast Dye Injector (brand name or equal) for the Rocky Mountain Regional VA Medical Center. This Sources Sought Notice is issued for information and planning purposes only. This is not a solicitation or a request for proposal and shall not be construed as an obligation or commitment by the Government. An award will not be made on any offers submitted in response to this notice, and it shall not be implied the Government is committed to providing any solicitation or award following this notice. The Government will not pay for any information received in response to this request, nor will the Government compensate a respondent for any costs incurred in developing the information provided. Salient Characteristics: -Multi-use syringe usage -Power requirements factory selectable 100 to 120 VAC, 50-60 Hz -10 A maximum or 200 to 240 VAC, 50-60 Hz -Up to a 30% reduction in contrast delivered to patient without compromising image quality -Real-time Dose Tracking -Hand Controller with Variable Rate Technology -Smaller Catheter use option -Twelve design elements that mitigate air injection during angiography -Multi-use syringe usage -Air Column Detect sensor -Manifold capability to prevent reverse flow -Automatic hemodynamic monitoring capability -Contrast flow rates: user-responsive, pre-set Variable and Fixed rates -Fixed saline flow rates -Injection modes: Cardiac & Peripheral Vascular -Pressure Limits minimum 200 to 1200psi -Allow contrast syringe for use in up to 6 patient cases -Single and dual pressure monitoring capability The purchase shall include manufacturer s warranty for the life of the equipment that begins on the date of installation. Warranty shall include the following: Preventive maintenance must be done by OEM certified technicians using OEM certified parts and should at minimum include the following: Annually: -Full system calibration and diagnostics -Software updates and hardware firmware verification -Inspection and replacement of internal filters -Verification of pressure sensor accuracy -Inspection of electrical components and mechanical joints -Safety checks -Grounding integrity -Emergency shutoff verification As Needed: OEM Repair Services Error Code Response and Diagnostics Part Number(s): CLIN Part Number Nomenclature Unit of Measure Quantity 0001 019398 ACIST CVi Contrast Dye Injector System with 7-year Warranty (Brand Name or Equal) EA 1 Responses shall be submitted to Noaa.Lanotte@va.gov by 10:00am MT on February 6, 2026. This notice is intended strictly for market research. The purpose of this Sources Sought Notice is to determine interest and capability of potential qualified sources of supply and determine the socioeconomic size classification of the supplier and manufacturer of the end item. Interested companies shall provide, at a minimum, the following information with their response; Company Name and Address: Point of Contact (POC) Name: Email Address: Phone Number: SAM.gov UEI: On GSA/FSS Schedule or VA Contract? Manufactured in the USA? The anticipated North American Industry Classification System (NAICS) code is 339112- Surgical and Medical Instrument Manufacturing. Mark if your firm is eligible for participation in one of the following small business programs. If so, please indicate the program: [ ] yes [ ] no - Small Business (SB) [ ] yes [ ] no - HUBZone [ ] yes [ ] no - Small Business 8(a) [ ] yes [ ] no - Small Disadvantaged Business (SDB) [ ] yes [ ] no - Women-Owned (WO) Small Business [ ] yes [ ] no - Service Disabled Veteran Owned Small Business (SDVOSB) [ ] yes [ ] no - Veteran Owned Small Business (VOSB) [ ] yes [ ] no - Large Business [ ] yes [ ] no - Other (please specify) Please answer the following questions: [ ] yes [ ] no - Does not exceed 500 employees; (for NAICS 339112), must be verifiable thru the System for Award Management) [ ] yes [ ] no - Is primarily engaged in the retail or wholesale trade and normally sells the type of item being supplied; [ ] yes [ ] no - Takes ownership or possession of the item(s) with its personnel, equipment or facilities in a manner consistent with industry practice (identify how this occurs); and [ ] yes [ ] no - Will supply the end item of a small business manufacturer, processor or producer made in the United States, or obtains a waiver of such requirement pursuant to paragraph (b)(5) CFR 121.406. Place of Manufacture:____________________________ Note: Do not include Proprietary, classified, confidential, or sensitive information in responses. In addition to providing the information requested above, responding companies are encouraged to include any relevant information (specifications, cut sheets, brochures, capability statement, past experience etc.) to confirm the company s ability to meet the requirements outlined in this request. Responses to this notice are not offers and cannot be accepted by the U.S. Government to form a binding contract or agreement. This notice shall not be construed as a commitment by the Government to issue a solicitation, or ultimately award a contract, nor does it restrict the Government to a particular acquisition approach. The Government will in no way be bound to this information if any solicitation is issued.

From Sources Sought posted on Jan 30, 2026

Notice history

1
  1. Sources Sought LATEST Posted Jan 30, 2026

Details

Solicitation number 36C25926Q0221
Notice ID 45e3ce3236f244879f522c5b0fe36a18
Notice type Sources Sought
Product / Service (PSC) 6515
NAICS 339112
Place of performance Aurora, Colorado
Archive date Mar 08, 2026

Award Information

Awardees
0

Documents

1
View on SAM.gov

Contacts

primary
Noaa Lanotte

Contracting Officer

Email

Phone

Agency

VETERANS AFFAIRS, DEPARTMENT OF
VETERANS AFFAIRS, DEPARTMENT OF
NETWORK CONTRACT OFFICE 19 (36C259)

Place of Performance

Department of Veterans Affairs Eastern Colorado VA Health Care System
Rocky Mountain Regional Medical Center 1700 North Wheeling Street
Aurora, Colorado 80045
USA

Dates

Posted Jan 30, 2026 6 months ago
Last Updated Aug 06, 2026 1 day ago
Due Feb 06, 2026 6 months ago