Contacts, documents and full notice history are available with a subscription.
Sources Sought Expired 1 notice 2 documents

6515--664-25-4-072-0186 Fluid Management System 36C26225Q1463

Solicitation 36C26225Q1463 Copied Notice ID 11d893eef0b34c0589b4d7312d1982d6 Copied VETERANS AFFAIRS, DEPARTMENT OF — 262-NETWORK CONTRACT OFFICE 22 (36C262)
SAM.gov
Posted
Aug 30, 2025
Deadline
Sep 04, 2025
Set-aside
None
NAICS
339112
PSC
6515

Summary

AI-generated · Sep 01, 2025

Provide a Fluid Management System based on Baxter’s Starling non-invasive fluid management monitoring technology for the VA San Diego Healthcare System. The effort seeks a system that supports continuous hemodynamic monitoring and fluid management across ICU, ED, Rapid Response, and OR, using non-invasive disposable leads. Required components include the Starling monitor, Starling Sensors, Passive Leg Raise Lift, Starling Roll Stand, and associated cables/accessories (e.g., Starling Patient Cable, Power Cable, and Non-Invasive Blood Pressure Module). Measurements must be obtainable non-invasively (without central/arterial lines or ventilation/intubation) and must assess stroke volume index in response to passive leg lift or IV fluid bolus, as well as Cardiac Output, Cardiac Index, Systemic Vascular Resistance, and Peripheral Vascular Resistance.

This is a market-information request (RFI/sources sought) for planning purposes, not a solicitation. Vendors are asked to submit a capabilities statement addressing how they meet or do not meet the listed draft salient characteristics, provide feedback or suggestions, and share business details (e.g., size status, manufacturer/distributor relationships, FDA clearance, lead times, and whether items are commercially available or on any Federal contracts). Responses will inform potential future RFIs or solicitations; non-response will not affect eligibility.

THIS REQUEST FOR INFORMATION (RFI)/SOURCES SOUGHT/RFI IS ISSUED SOLELY FOR INFORMATION AND PLANNING PURPOSES ONLY. THIS IS NOT A SOLICITATION. THE SUBMISSION OF PRICING, CAPABILITIES FOR PLANNING PURPOSES, AND OTHER MARKET INFORMATION IS HIGHLY ENCOURAGED AND ALLOWED UNDER THIS RFI IN ACCORDANCE WITH (IAW) FAR 15.201(e). DISCLAIMER This RFI is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. IAW FAR 15.201(e), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI. SOURCES SOUGHT/RFI DESCRIPTION This is NOT a solicitation announcement. This is a Sources Sought/RFI only. The purpose of this Sources Sought/RFI is to gain knowledge of potential qualified sources and their size classification relative to NAICS 339112 (size standard of 1,000 Employees). Responses to this RFI/Sources Sought Notice will be used by the Government to make appropriate acquisition decisions. After review of the responses to this RFI/Sources Sought Notice, further RFIs and/or a solicitation or other announcements may be published. The Department of Veterans Affairs (VA), VISN 22 Long Beach Network Contracting Office is seeking sources capable of providing Fluid Management System for the VA San Diego Healthcare System that can address the draft salient characteristics described below. Brandname Information: Manufacturer & Part Number(s): Baxter Healthcare, CMMST5 Type: The starling non invasive fluid management monitoring system provides continuous hemodynamic monitoring and empowers fluid management across the continuum of care: ICU, ED, RRT and OR A portable and lightweight touch screen monitor: H:8.7 , W:11.4 , D:7.4 9.5 lbs., 10.4 6 hour battery life. Includes Starling Patient Cable, Starling Power Cable, and Non Invasive Blood Pr essure Module Equal to product name: Fluid Management System Manufacturer & Part Number(s): Baxter Healthcare, CMS25 Type: Starling Sensors (25/BX) Equal to product name: Sensors Manufacturer & Part Number(s): Baxter Healthcare, CMALIFT Type: Passive Leg Raise Lift Equal to product name: Lift Manufacturer & Part Number(s): Baxter Healthcare, CMASRS20S1 Type: Starling Roll Stand Equal to product name: Roll Stand Salient Characteristics: Must utilize non-invasive technology (i.e., disposable leads) to assess stroke volume index in response to passive leg lift or IV fluid bolus Must utilize non-invasive technology (i.e., disposable leads) to assess Cardiac Output, Cardiac Index, Systemic Vascular Resistance or Peripheral Vascular Resistance The above measurements must not require the use of central line, arterial line, or airway intubation and ventilation The list of draft characteristics is intended to be descriptive, not restrictive, of the supplies and/or services that are required. If your company is interested and capable of providing the required supplies/services, please provide the information indicated below. Response to this notice should include company name, address, point of contact, size of business pursuant to the following questions: (1) Submit your capabilities statement illustrating how your organization can/cannot meet the list of draft salient characteristics described below. For instances where your company cannot meet the draft salient characteristic(s), please explain. For instances where your company can meet the draft salient characteristic(s), please show how your company meets/exceeds each requirement. (2) Please review the list of draft salient characteristics and provide any additional feedback or suggestions. If none, please reply as N/A. (3) Please indicate the size status and representations of your business, such as but not limited to: Service-Disabled Veteran-Owned Small Business (SDVOSB), Veteran-Owned Small Business (VOSB), HUBZone, Woman Owned Small Business (WOSB), Large Business, etc. (4) Is your company considered small under the NAICS code identified in this RFI? (5) Are you the manufacturer, authorized distributor, and/or can your company provide a solution to the required supplies/services described in the list of draft salient characteristics? (6) If you are a large business, do you have any designated/authorized distributors? If so, please provide their company name, telephone, point of contact and size status (if available). (7) If you re a small business and you are an authorized distributor/reseller for the items identified above, do you alter, assemble, or modify the items requested in any way? If you do, state how and what is altered, assembled, or modified. (8) Limitations on Subcontracting: How does your business ensure compliance with the limitations on subcontracting as outlined in 13 CFR 125.6? (9) Are the items you are identifying/providing considered Commercial of the Shelf (COTS) items as defined in FAR Part 2.101 under commercial items? (10) Non-Manufacturer Rule: If applicable, can you confirm your business complies with the Non-Manufacturer rule? Specifically, does your company: Provide a product from a small business manufacturer or processor? Not exceed 500 employees? Primarily engage in the retail or wholesale trade and normally sell the type of item being supplied? Take ownership or possession of the item(s) with its personnel, equipment or facilities in a manner consistent with industry practice? (11) Please indicate whether your product conforms to the requirements of the Buy American Act? If you are unsure, please state the country of origin for each item. (12) What is your lead time to deliver all items? (13) Does your proposed equipment have FDA clearance (if needed)? Please specify what FDA clearance(s) have been obtained. (14) Does your company have a Federal Supply Schedule (FSS) GSA/NAC/SAC/BPA/NASA SEWP or any other Federal Government contract? If so, please provide the contract number(s). (15) If you are an FSS GSA/NAC/SAC/BPA/NASA SEWP or any other Federal Government contract holder, are all the items/solutions you are providing information about available on your schedule/contract? Please state if all or some items are available on the contract. (16) General pricing of your products/solution is encouraged. Pricing will be used for the purpose of market research only. It will not be used to evaluate for any type of award. (17) Please provide your SAM.gov Unique Entity ID number. Responses to this notice shall be submitted via email to Emiljan.Golemi@va.gov. Telephone responses will not be accepted. Responses must be received no later than Thursday, September 4, 2025, by 4:00 PM PST. All responses to this RFI/Sources Sought will be used for planning purposes only. Responses to this RFI/Sources Sought Notice are not considered a request to be added to a prospective bidders list or to receive a copy of the solicitation. If further RFIs and/or a solicitation or other announcement is issued because of the information provided from this RFI, all interested parties must respond to the specific posting separately in accordance with the specifications of that announcement.

From Sources Sought posted on Aug 30, 2025

Notice history

1
  1. Sources Sought LATEST Posted Aug 30, 2025 View

Details

Solicitation number 36C26225Q1463
Notice ID 11d893eef0b34c0589b4d7312d1982d6
Notice type Sources Sought
Product / Service (PSC) 6515
NAICS 339112
Archive date Oct 04, 2025

Award Information

Awardees
0

Contacts

primary
Emiljan Golemi

Contract Specialist

Email

Agency

VETERANS AFFAIRS, DEPARTMENT OF
VETERANS AFFAIRS, DEPARTMENT OF
262-NETWORK CONTRACT OFFICE 22 (36C262)

Place of Performance

Dates

Posted Aug 30, 2025 11 months ago
Last Updated Aug 06, 2026 1 day ago
Due Sep 04, 2025 11 months ago