50 CES Burn Tower Maintenance FA255025Q0038

Solicitation FA255025Q0038 Copied Notice ID 0450411807fb4fdd912cfd845b153902 Copied DEPT OF DEFENSE — FA2550 50 CONS PKP
SAM.gov
Posted
Aug 05, 2025
Deadline
Aug 08, 2025
Set-aside
SBA
NAICS
811310
PSC
J036

Summary

AI-generated · Aug 24, 2025

Furnish all labor, parts, materials, equipment, and transportation to inspect and maintain the Fire Department Burn House and other firefighting training props at Schriever SFB, ensuring they are inspected, maintained, and updated in accordance with NFPA 1403 Live Fire Training Evolutions, manufacturers’ specifications, and all applicable standards.

RFI responses clarify that annual service must be performed by a qualified Integrated Control Systems (ICS) technician, with certification by the contractor acceptable for annual inspections (in compliance with NFPA and related regulations). A licensed professional engineer is required for the 5-year structural inspection per NFPA 1403, and a 5-year PE inspection report is attached. The government indicates 15–20 training exercises per year are conducted (including mutual aid partners), and the Burn Tower/training props are in good working order; an Operation and Maintenance Manual is available.

The contractor shall furnish all labor, parts materials, equipment, and transportation necessary to perform inspection and maintenance of Fire Department Burn House and other Firefighting props at Schriever SFB (SSFB). The intent of this PWS is to ensure that the Burn House and training props are inspected, maintained, and updated in accordance with National Fire Protection Association Standard (NFPA) 1403 Live Fire Training Evolutions and manufacturers specifications and all other applicable standards. Please see attachments for the solicitation documents and attachments.

From Combined Synopsis/Solicitation posted on Jul 21, 2025

The contractor shall furnish all labor, parts materials, equipment, and transportation necessary to perform inspection and maintenance of Fire Department Burn House and other Firefighting props at Schriever SFB (SSFB). The intent of this PWS is to ensure that the Burn House and training props are inspected, maintained, and updated in accordance with National Fire Protection Association Standard (NFPA) 1403 Live Fire Training Evolutions and manufacturers specifications and all other applicable standards. Please see attachments for the solicitation documents and attachments. Please see RFI responses below: May we see the most recent inspection reports for each of the trainers? ---will the second attached document suffice? PWS Paragraph 1.1.3 specifies that the annual service must be completed by a qualified ICS technician. Can we assume this means an Integrated Control Systems technician? --- I believe so Is there specific documentation the Government is looking for to determine whether someone is a qualified ICS technician, per PWS Paragraph 1.1.3? Is field experience sufficient qualification? ---If they are certified by the company to conduct inspections on burn trainers, I believe they would have to be properly compliant as a prerequisite for the job. We will research further. Are all systems and components of the Burn Tower currently in good working order and functional? ---yes When was the last time the Burn Tower had a documented 5-year inspection completed by a licensed professional engineer? May we see the report? ---Attached in this email PWS Paragraph 1.2 outlines a requirement for a licensed professional engineer to complete the inspection and documentation for the Burn Tower. Paragraph 1.2.1 states that evaluation of structural live fire trainer shall be conducted in accordance with NFPA 1403. NFPA 1403 states that a licensed structural engineer should complete an inspection every 5 years. Is Schriever SFB requesting the full inspection by a licensed engineer every year for this contract beyond NFPA requirements, or is an experienced technician sufficient for regular annual inspections? ---A certified technician that can legally sign off for annual inspections in compliance with NFPA and other necessary regulations is sufficient Are all the training props in good working order and functional? ---Yes May we see an Operation and Maintenance Manual for the Burn Tower and all training props? ---With our Assistant Chief for Training (in his office) How many training exercises are performed at the Burn Tower and on each training prop per year? ---15-20 with Mutual aid partners as well

From Combined Synopsis/Solicitation posted on Aug 05, 2025

Notice history

2
  1. Combined Synopsis/Solicitation Posted Jul 21, 2025 View
  2. Combined Synopsis/Solicitation LATEST Posted Aug 05, 2025
    • Description: Description was updated
    • Response Deadline: Aug 05, 2025Aug 08, 2025

Details

Solicitation number FA255025Q0038
Notice ID 0450411807fb4fdd912cfd845b153902
Notice type Combined Synopsis/Solicitation
Product / Service (PSC) J036
NAICS 811310
Place of performance Colorado Springs, Colorado
Archive date Aug 23, 2025

Award Information

Not yet awarded

Contacts

primary
Danielle Hunziker

Email

Phone

secondary
Tatum Kiley

Email

Phone

Agency

DEPT OF DEFENSE
DEPT OF THE AIR FORCE
FA2550 50 CONS PKP

Place of Performance

Colorado Springs, Colorado 80912
USA

Dates

Posted Aug 05, 2025 1 year ago
Last Updated Aug 06, 2026 1 day ago
Due Aug 08, 2025 11 months ago