4120--QTY-1EA, Computer Room Air Conditioning (CRAC) unit 36C26025Q0683
Summary
AI-generated · Aug 25, 2025Procurement and delivery of a Computer Room Air Conditioning (CRAC) unit to replace a 25-year-old unit at Mann Grandstaff VA Medical Center, Spokane, WA. The vendor will supply the latest-model CRAC unit that matches the draft SOW’s specifications (upflow design with front air return, ICOM control with high-definition display and BACnet comms, variable-speed EC fans, digital scroll compressor with approved refrigerant, high-efficiency filtration, multiple sensors, leak detection, and internal condensate pump), and deliver the unit with all required documentation (data sheets, installation/maintenance manuals, warranty information). Delivery and packaging requirements specify outdoor-ready packaging and delivery to the Spokane facility, along with compliance to applicable ASHRAE, ASME, and UL standards and a comprehensive manufacturer's warranty. The equipment list identifies a target unit (specific model) with performance metrics (approx. 2800 CFM, 63 KBtu/hr, 208/60V-3Ph-60Hz) and precise dimensional limits.
This is a sources-sought market research effort, not a bid solicitation, seeking qualified manufacturers or authorized distributors and asking respondents to provide company details, eligibility for small-business programs, lead times for a QTY 1 CRAC unit, any federal contracts, and a capability statement. The responses should also cover what additional information would be needed to estimate the work and confirm capability to meet the draft SOW. The two notices are substantively identical, with no awards announced yet (award data show $0.00), so there is no change in scope or new information between them.
DESCRIPTION THIS IS A REQUEST FOR INFORMATION ONLY. This is not a solicitation for bids, proposals, proposal abstracts, or quotations. The purpose of this sources sought to obtain information regarding the availability and capability of all qualified sources to perform a potential requirement. The responses received from interested contractors will assist the Government in determining the appropriate acquisition method. The Department of Veterans Affairs (VA), Network Contracting Office (NCO) 20, is conducting market research to identify potential sources which can provide the following services: Proposed NAICS Code 333415. Any questions or concerns may be directed to Derek Crockett via e-mail at derek.crockett@va.gov. RESPONSES SHOULD INCLUDE THE FOLLOWING INFORMATION AND RESPONSES TO THE FOLLOWING QUESTIONS: 1.) Company name, address, and business size; point of contact name, phone number, and e-mail address. 2.) Is your firm eligible for participation in one of the following small business programs? If so, please indicate the program and the anticipated North American Industry Classification System (NAICS) code. [ ] yes [ ] no Small Business (SB) [ ] yes [ ] no HUBZone [ ] yes [ ] no Small Business 8(a) [ ] yes [ ] no Small Disadvantaged Business (SDB) [ ] yes [ ] no Women-Owned (WO) Small Business [ ] yes [ ] no Service Disabled Veteran Owned Small Business (SDVOSB) [ ] yes [ ] no Veteran Owned Small Business (VOSB) [ ] yes [ ] no Other (please specify) 3.) Are you a manufacturer or authorized distributor of Computer Room Air Conditioning (CRAC) units? Is yes, what manufacturer(s) and model(s) are you authorized to distribute, and what length of warranty length and terms come with a unit? 4.) What are you estimated lead times for ordering and delivery of QTY1EA CRAC unit? 5.) Does your firm have any existing contracts with the federal government or specific government agencies? (GSA, FSS, ect). If yes, please list the contract number(s) and agency contracts. 6.) Based on the Draft Statement of Work (SOW) and scope of services stated below, what additional information would you need to accurately estimate the effort for this requirement? 7.) Please provide a capability statement (not to exceed 5 pages) detailing any current or historical projects for similar requirements. DRAFT STATEMENT OF WORK (SOW): DRAFT Statement of Work (SOW) - Procurement of CRAC Unit Precision Cooling 1.0 General This Statement of Work (SOW) outlines the requirements for the procurement and delivery of Computer Room Air Conditioning (CRAC) unit. The CRAC unit is required by MANN GRANDSTAFF VA Medical Center Spokane, WA. to replace an aged 25-year-old unit obsolete unit. 2.0 Scope of Work The Vendor shall furnish the latest model CRAC unit, compliant with the specifications outlined in Section 3.0. The scope of work includes, but is not limited to: Procurement: Supply of the specified CRAC units as detailed in the Equipment List (Section 3.1). Delivery: Delivery of the CRAC unit to 4815 N. Assembly Street, Spokane, WA. 99208. Required Delivery Date: 10/01/25. Documentation: Providing all necessary documentation, including but not limited to: Manufacturer's technical data sheets Installation, operation, and maintenance manuals Warranty information 3.0 Equipment List Location Quantity Specifications Design Basis Telecomm Room Building 1 Room B0114A-CRAC 1 2800 CFM, 63 KBTU/HR, at Approx 75F-45%RH 208/60V-3Ph-60Hz, 76.5 FLA., 81.5 WSA,90 OPD, Up flow VERTIV PX018UA1CB 3.1 General Requirements Compliance: The CRAC units shall comply with all applicable ASHRAE, ASME, and UL standards. Systems Details: Up flow with front air return ICOM control with high-definition display ICOM based comms BACnet Variable speed EC plug fans digital scroll variable capacity compressor utilizing environmental approved refrigerant. Evaporator type tilted-slab, cooper tubes, aluminum fins with hydrophilic coating infrared humidification 65,000Amp, rms short circuit current rating locking disconnect switch Dual-float CONDENSATE PUMP FACTORY MOUNTED INTERNAL TO UNIT Filter rating MERV 13 per ASHRAE Supply air sensor Smoke sensor Temperature/humidity sensors internal for return air sensing one remote shut down contact three alarm contacts discharge grill plenum-3 way discharge Point LEAK DETECTION SENSOR Air cooled microchannel condenser/ 208 v/3 PHASE. 60Hz, 2.3FLA,209WSA,15OPD Dimensions: Height: no more than 77 9/16 Width: 34 Depth:34 5/8 4.0 Deliverables The Contractor shall deliver the following: CRAC units as specified in Section 3.0. All required documentation as outlined in Section 2.0. Equipment shall be secured & packaged for outdoor, uncovered storage until installation. Delivery shall take place at: Delivery of the CRAC unit to 4815 N. Assembly Street, Spokane, WA. 99208. Required Delivery Date: 10/01/25. 5.0 Warranty The CRAC units shall be covered by a comprehensive manufacturer's warranty.
From Sources Sought posted on Jun 30, 2025DESCRIPTION THIS IS A REQUEST FOR INFORMATION ONLY. This is not a solicitation for bids, proposals, proposal abstracts, or quotations. The purpose of this sources sought to obtain information regarding the availability and capability of all qualified sources to perform a potential requirement. The responses received from interested contractors will assist the Government in determining the appropriate acquisition method. The Department of Veterans Affairs (VA), Network Contracting Office (NCO) 20, is conducting market research to identify potential sources which can provide the following services: Proposed NAICS Code 333415. Any questions or concerns may be directed to Derek Crockett via e-mail at derek.crockett@va.gov. RESPONSES SHOULD INCLUDE THE FOLLOWING INFORMATION AND RESPONSES TO THE FOLLOWING QUESTIONS: 1.) Company name, address, and business size; point of contact name, phone number, and e-mail address. 2.) Is your firm eligible for participation in one of the following small business programs? If so, please indicate the program and the anticipated North American Industry Classification System (NAICS) code. [ ] yes [ ] no Small Business (SB) [ ] yes [ ] no HUBZone [ ] yes [ ] no Small Business 8(a) [ ] yes [ ] no Small Disadvantaged Business (SDB) [ ] yes [ ] no Women-Owned (WO) Small Business [ ] yes [ ] no Service Disabled Veteran Owned Small Business (SDVOSB) [ ] yes [ ] no Veteran Owned Small Business (VOSB) [ ] yes [ ] no Other (please specify) 3.) Are you a manufacturer or authorized distributor of Computer Room Air Conditioning (CRAC) units? Is yes, what manufacturer(s) and model(s) are you authorized to distribute, and what length of warranty length and terms come with a unit? 4.) What are you estimated lead times for ordering and delivery of QTY1EA CRAC unit? 5.) Does your firm have any existing contracts with the federal government or specific government agencies? (GSA, FSS, ect). If yes, please list the contract number(s) and agency contracts. 6.) Based on the Draft Statement of Work (SOW) and scope of services stated below, what additional information would you need to accurately estimate the effort for this requirement? 7.) Please provide a capability statement (not to exceed 5 pages) detailing any current or historical projects for similar requirements. DRAFT STATEMENT OF WORK (SOW): DRAFT Statement of Work (SOW) - Procurement of CRAC Unit Precision Cooling 1.0 General This Statement of Work (SOW) outlines the requirements for the procurement and delivery of Computer Room Air Conditioning (CRAC) unit. The CRAC unit is required by MANN GRANDSTAFF VA Medical Center Spokane, WA. to replace an aged 25-year-old unit obsolete unit. 2.0 Scope of Work The Vendor shall furnish the latest model CRAC unit, compliant with the specifications outlined in Section 3.0. The scope of work includes, but is not limited to: Procurement: Supply of the specified CRAC units as detailed in the Equipment List (Section 3.1). Delivery: Delivery of the CRAC unit to 4815 N. Assembly Street, Spokane, WA. 99208. Required Delivery Date: 10/01/25. Documentation: Providing all necessary documentation, including but not limited to: Manufacturer's technical data sheets Installation, operation, and maintenance manuals Warranty information 3.0 Equipment List Location Quantity Specifications Design Basis Telecomm Room Building 1 Room B0114A-CRAC 1 2800 CFM, 63 KBTU/HR, at Approx 75F-45%RH 208/60V-3Ph-60Hz, 76.5 FLA., 81.5 WSA,90 OPD, Up flow VERTIV PX018UA1CB 3.1 General Requirements Compliance: The CRAC units shall comply with all applicable ASHRAE, ASME, and UL standards. Systems Details: Up flow with front air return ICOM control with high-definition display ICOM based comms BACnet Variable speed EC plug fans digital scroll variable capacity compressor utilizing environmental approved refrigerant. Evaporator type tilted-slab, cooper tubes, aluminum fins with hydrophilic coating infrared humidification 65,000Amp, rms short circuit current rating locking disconnect switch Dual-float CONDENSATE PUMP FACTORY MOUNTED INTERNAL TO UNIT Filter rating MERV 13 per ASHRAE Supply air sensor Smoke sensor Temperature/humidity sensors internal for return air sensing one remote shut down contact three alarm contacts discharge grill plenum-3 way discharge Point LEAK DETECTION SENSOR Air cooled microchannel condenser/ 208 v/3 PHASE. 60Hz, 2.3FLA,209WSA,15OPD Dimensions: Height: no more than 77 9/16 Width: 34 Depth:34 5/8 4.0 Deliverables The Contractor shall deliver the following: CRAC units as specified in Section 3.0. All required documentation as outlined in Section 2.0. Equipment shall be secured & packaged for outdoor, uncovered storage until installation. Delivery shall take place at: Delivery of the CRAC unit to 4815 N. Assembly Street, Spokane, WA. 99208. Required Delivery Date: 10/01/25. 5.0 Warranty The CRAC units shall be covered by a comprehensive manufacturer's warranty.
From Sources Sought posted on Jul 10, 2025Notice history
2-
-
Sources Sought LATEST Posted Jul 10, 2025View changes (1)
- Response Deadline: Jul 10, 2025 → Jul 18, 2025
Details
Award Information
Contacts
Contract Specialist
Phone
Agency
Place of Performance
4815 N Assembly St,
Spokane, Washington 99205