4120--Mobile Chiller 36C24825Q1093
Summary
AI-generated · Aug 27, 2025A mobile chiller system is being sought to provide backup cooling for the James A. Haley VA Healthcare System, interchangeable between Building 100 Bed Tower and Building 39 Central Energy Plant. Due to space limitations, two 500-ton chillers are not acceptable. The package must include design and engineering analyses, modification of a 40 ft by 9 ft-6 in container to house the chiller, and a 48-step deck trailer. It requires delivery of a 1000-ton Dunham Bush modular magnetic bearing chiller (refrigerant 513A, 460V/3/60, five magnetic bearing compressors) with non-OEM/non-proprietary onboard controls, BACnet compatibility, isolation valves, and a five-year compressor warranty (parts only) plus a one-year warranty on all parts and labor; plus a 100 HP base-mount chilled-water pump and a 100 HP base-mount condenser-water pump (both 460V/3 with 100 ft head), two 100 HP VFDs for pumps, and the installation of a packaged air conditioning unit on a closed container.
Purpose is to ensure a reliable backup cooling capability to prevent water-temperature excursions that could disrupt hospital operations and patient care. The vendor must provide personnel who are qualified and able to furnish documentation on request, deliver to the hospital, and supply a standard manufacturer warranty (no extended warranty paid in advance). Responses should include company information, capability statement, prior similar projects with references, approximate lead time for delivery and installation, relevant certifications, a letter authorizing product distribution, and country of origin, all submitted electronically in PDF format as part of a market research response.
Sources Sought Notice Title: Mobile Chiller for James A. Haley VA Healthcare System Synopsis: This is a Sources Sought notice seeking information and capabilities from qualified vendors for the procurement of a mobile chiller system for the James A. Haley VA Healthcare System. Due to spatial constraints, the use of two 500-ton chillers is not acceptable. This notice is issued for market research purposes only and does not constitute a solicitation or a promise to issue a solicitation in the future. Background: With the expansion at the James A. Haley VA Healthcare System (JAHVA), the current number of chillers is running at maximum capacity. If one chiller goes down for repairs, it will impact water temperatures to critical levels in areas of the hospital, causing major disruptions to hospital operations and patient care, potentially resulting in the need for patient relocation. Scope: The Facility Management Section requires a mobile chiller that can be used interchangeably at Building 100 Bed Tower and Building 39 Central Energy Plant (CEP). The contractor is expected to deliver the necessary components to build a mobile chiller package that meets or exceeds the salient characteristics provided. The solution must accommodate the following specifications: Design and engineering services, including mechanical and electrical analysis. Modification and insulation of a 40 long by 9 6 high shipping container to house the new chiller package. Provision of a 48 step deck trailer. Delivery of a 1000 Ton Dunham Bush modular magnetic bearing chiller with refrigerant 513A, 460V/3/60, 5 magnetic bearing compressors, electrical line reactors, internal variable speed drives, onboard controls (non-OEM and non-proprietary), BACnet compatibility, chiller isolation valves, and a five-year warranty on compressors (parts only) plus a one-year warranty on all parts and labor. Provision of a 100 HP base mount chilled water pump and a 100 HP base mount condenser water pump (both 460V/3 with 100 of head). Delivery of two 100 HP VFDs for pumps. Provision and installation of a package air conditioning unit to be mounted on a closed container. Purpose: The purpose of this requirement is to ensure backup chiller capability in case of failure, thereby maintaining continuous patient care. Warranty: The government requires a standard manufacturer industry warranty term. No extended warranty requiring advance payment will be accepted. Delivery Schedule: All deliveries to be made to 13000 Bruce B Downs Blvd, Tampa, Florida 33612. Place of Delivery: James A. Haley Veterans Hospital, Facility Maintenance Central Energy Plant Building 39, Tampa, FL 33612. Personnel Qualifications: Contractor personnel must be competent, dependable, knowledgeable, trained, certified, licensed, and experienced. The government reserves the right to request copies of personnel qualifications during performance. The contractor must provide the requested information within five (5) business days of the request. Submission Instructions: Interested vendors are requested to provide the following information in their response: Company Name, Address, and Point of Contact Information Capability Statement demonstrating the ability to meet the requirements Previous experience with similar projects, including contract numbers and points of contact Approximate lead time for delivery and installation of the chiller system Any relevant certifications or industry standards held by the company Letter of Authorization to distribute product. Origin of country Responses to this Sources Sought notice should be submitted electronically to [Marcus Lewis] by [9/3/2025]. All responses should be submitted via email only in PDF format hyperlinks will not be accepted. Disclaimer: This notice is for informational purposes only and does not oblige James A. Haley VA Healthcare System to award a contract or pay for any information solicited. Respondents will not be notified of the results of the market research. All information received in response to this notice will be used for planning purposes only. Contact Information: For any questions or further information, please contact: [Marcus.Lewis2@va.gov] We appreciate your interest and look forward to receiving your submission.
From Sources Sought posted on Aug 26, 2025James A. Haley VA Healthcare System Mobile Chiller for B39 and B100 GENERAL: James A Haley VA Hospital, 13000 Bruce B Downs Blvd. FL. 33612, has a need for a Mobile Chiller for CEP BACKGROUND: With the expansion at JAHVA, the current number of chillers is running at maximum compacity. If one chiller goes down for repairs, it will impact water temperatures to critical levels in areas of the hospital. Causing a major devastation to hospital operations and patient care. Possible relocation of patients. SCOPE: The Facility Management Section requires a Mobile Chiller that can be used where needed B100 or B39. The connections will be located at Building 100 Bed Tower and building 39 Central Energy Plant (CEP). The contractor shall provide and deliver major components to build mobile chiller packages that meets or exceeds the salient characteristics provided.
From Combined Synopsis/Solicitation posted on Sep 09, 2025STATEMENT OF NEED James A. Haley VA Healthcare System Mobile Chiller for B39 and B100 GENERAL: The James A. Haley Veterans Hospital (JAHVH) Facilities Management Service (FMS), Maintenance and Operations Team, has identified a critical need for this requirement to ensure uninterrupted climate control in both B39 and B100 buildings. To address this need, the Engineering team proposes the purchase of a Mobile Chiller that offers the flexibility to be deployed at either location as needed. This mobile chiller will serve as a backup to mitigate the risk posed by faulty or broken chillers, ensuring the hospital's climate control system remains operational during repairs to the main chillers. The mobile unit can be rapidly relocated to any building experiencing chiller failure, thereby preventing any disruption in climate control and maintaining a comfortable and safe environment for patients and staff BACKGROUND: With the expansion at JAHVA, the current number of chillers is running at maximum compacity. If one chiller goes down for repairs, it will impact water temperatures to critical levels in areas of the hospital. Causing a major devastation to hospital operations and patient care. Possible relocation of patients.
From Combined Synopsis/Solicitation posted on Sep 15, 2025STATEMENT OF NEED James A. Haley VA Healthcare System Mobile Chiller for B39 and B100 GENERAL: James A Haley VA Hospital, 13000 Bruce B Downs Blvd. FL. 33612, has a need for a Mobile Chiller for CEP BACKGROUND: With the expansion at JAHVA, the current number of chillers is running at maximum compacity. If one chiller goes down for repairs, it will impact water temperatures to critical levels in areas of the hospital. Causing a major devastation to hospital operations and patient care. Possible relocation of patients.
From Combined Synopsis/Solicitation posted on Sep 18, 2025STATEMENT OF NEED James A. Haley VA Healthcare System Mobile Chiller for B39 and B100 GENERAL: The James A. Haley Veterans Hospital (JAHVH) Facilities Management Service (FMS), Maintenance and Operations Team, has identified a critical need for this requirement to ensure uninterrupted climate control in both B39 and B100 buildings. To address this need, the Engineering team proposes the purchase of a Mobile Chiller that offers the flexibility to be deployed at either location as needed. This mobile chiller will serve as a backup to mitigate the risk posed by faulty or broken chillers, ensuring the hospital's climate control system remains operational during repairs to the main chillers. The mobile unit can be rapidly relocated to any building experiencing chiller failure, thereby preventing any disruption in climate control and maintaining a comfortable and safe environment for patients and staff BACKGROUND: With the expansion at JAHVA, the current number of chillers is running at maximum compacity. If one chiller goes down for repairs, it will impact water temperatures to critical levels in areas of the hospital. Causing a major devastation to hospital operations and patient care. Possible relocation of patients.
From Combined Synopsis/Solicitation posted on Sep 22, 2025STATEMENT OF NEED James A. Haley VA Healthcare System Mobile Chiller for B39 and B100 GENERAL: The James A. Haley Veterans Hospital (JAHVH) Facilities Management Service (FMS), Maintenance and Operations Team, has identified a critical need for this requirement to ensure uninterrupted climate control in both B39 and B100 buildings. To address this need, the Engineering team proposes the purchase of a Mobile Chiller that offers the flexibility to be deployed at either location as needed. This mobile chiller will serve as a backup to mitigate the risk posed by faulty or broken chillers, ensuring the hospital's climate control system remains operational during repairs to the main chillers. The mobile unit can be rapidly relocated to any building experiencing chiller failure, thereby preventing any disruption in climate control and maintaining a comfortable and safe environment for patients and staff BACKGROUND: With the expansion at JAHVA, the current number of chillers is running at maximum compacity. If one chiller goes down for repairs, it will impact water temperatures to critical levels in areas of the hospital. Causing a major devastation to hospital operations and patient care. Possible relocation of patients.
From Combined Synopsis/Solicitation posted on Sep 23, 2025Notice history
7-
Sources Sought Posted Aug 26, 2025
-
Combined Synopsis/Solicitation Posted Sep 09, 2025View changes (3)
- Description: Description was updated
- Notice Type: Sources Sought → Combined Synopsis/Solicitation
- Response Deadline: Aug 29, 2025 → Sep 24, 2025
-
Combined Synopsis/Solicitation Posted Sep 15, 2025View changes (1)
- Description: Description was updated
-
Combined Synopsis/Solicitation Posted Sep 18, 2025View changes (1)
- Description: Description was updated
-
Combined Synopsis/Solicitation Posted Sep 22, 2025View changes (1)
- Description: Description was updated
-
Combined Synopsis/Solicitation Posted Sep 23, 2025No changes from previous notice
-
Award Notice LATEST Posted Sep 26, 2025
Details
Award Information
Awardees
| Company Name | UEI | CAGE Code | Location |
|---|---|---|---|
| OST SERVICES, LLC | MUPCLDFAHJK5 | 7TX86 | TAMPA |
Contacts
Contracting Officer
Phone
Agency
Place of Performance
13000 Bruce B. Down Blvd
Tampa, Florida 33579
USA