Contacts, documents and full notice history are available with a subscription.
Solicitation Expired 3 notices 2 documents

26-SIMACQ-E50-0001 -Missile Restraint System Control Console N6339426Q4005

Solicitation N6339426Q4005 Copied Notice ID be9c2c66b38244e19f2f2b94c287dda9 Copied DEPT OF DEFENSE — COMMANDING OFFICER
SAM.gov
Posted
Nov 21, 2025
Deadline
Dec 02, 2025
Set-aside
None
NAICS
335314
PSC
6110

Summary

AI-generated · Nov 22, 2025

Fabricate a Missile Restraint System Control Console with interfaces to detect PIN-to-SOCKET alignment via CR Adapter photo sensors, using green/red lights to indicate go/no-go; and to engage/disengage SOCKETS and PINS via CR Adapter pneumatic actuators, with green/red push-buttons for go/no-go, while monitoring limit switches during extend/retract operations.

Provide onsite installation support at the Missile-Intermediate Level Maintenance Facility (M-ILMF) to verify connections to the facility-provided electrical power receptacle, including the power supply, photo sensors, limit switches, and pneumatic actuators solenoid valves; connect the pneumatic actuators to the facility-provided compressed air drop; and ensure satisfactory performance of the completed control system after installation. Drawings are available upon request and approval.

Sources Sought Only Drawings are available upon request and approval. Fabricate a Control Console to include interfaces to perform the following: o Detect and indicate PIN-to-SOCKET proper alignment (performed by CR Adapter s Photo Sensors). This can be accomplished by using green/red LIGHTS for a go/no-go condition, respectively. o Engage/disengage SOCKETS and PINS (performed by the CR Adapter s pneumatic actuators). This can be accomplished by using green/red PUSH-BUTTONS for a go/no-go condition, respectively. The actuators limit switches need to be monitored during extend/retract operations. Provide support during the onsite installation at Missile-Intermediate Level Maintenance Facility (M-ILMF) to monitor the following: o Connection of the Control Console to the facility-provided Electrical Power Receptacle, including connections to the Power Supply, Photo Sensors, Limit Switches and Pneumatic Actuators Solenoid Valves o Connection of the Pneumatic Actuators to the facility-provided Compressed Air Drop o Ensure satisfactory performance of the completed Control System after installation

From Sources Sought posted on Nov 21, 2025

Sole Source Solicitation Documents attached for review.

From Solicitation posted on Dec 29, 2025

Sole Source Solicitation Documents attached for review.

From Solicitation posted on Jan 12, 2026

Notice history

3
  1. Sources Sought Posted Nov 21, 2025
  2. Solicitation Posted Dec 29, 2025
    • Description: Description was updated
    • Notice Type: Sources SoughtSolicitation
    • Response Deadline: Dec 02, 2025Jan 12, 2026
  3. Solicitation LATEST Posted Jan 12, 2026
    • Response Deadline: Jan 12, 2026Jan 16, 2026

Details

Solicitation number N6339426Q4005
Notice ID be9c2c66b38244e19f2f2b94c287dda9
Notice type Sources Sought
Product / Service (PSC) 6110
NAICS 335314
Place of performance Port Hueneme CBC Base, California
Archive date Dec 17, 2025

Award Information

Not yet awarded

Contacts

primary
Marvin Colato

Email

Phone

secondary
ARTHUR WYNN

Email

Agency

DEPT OF DEFENSE
DEPT OF THE NAVY
NAVSEA
NAVSEA WARFARE CENTER
COMMANDING OFFICER

Place of Performance

Port Hueneme CBC Base, California 93043
USA

Dates

Posted Nov 21, 2025 8 months ago
Last Updated Aug 06, 2026 2 days ago
Due Dec 02, 2025 8 months ago