20 SF Armory's IDS Upgrades FA480325R0027
Summary
AI-generated · Aug 23, 2025Upgrade the Honeywell Vindicator Intrusion Detection System at Buildings 825, 1843, and 1865 Armories by replacing the existing panels (two AES-1500s and one ACS V5) with upgraded devices running Windows 10/VR 22 firmware. All sensors, keypads, and duress buttons must be replaced with the newest approved devices per the Non-Nuclear Configuration Management Database Equipment Approval letter from AFSFC/FP (CMD); each device must include a tamper switch and be programmed as an alarm point. All alarm points must be a single alarm point with no daisy chaining. The upgraded IDS must be integrated into the current Security Forces Head End IDS system that reports to BDOC and the Alternate BDOC. All network/IDS cabling must be replaced and run in conduit where needed, and all junction boxes or splice points must have tamper and alarm features.
Both records are identical; there is no change in scope or new information between notices.
The 20 Security Forces Squadron is replacing the current Honeywell Vindicator Intrusion Detection System (IDS) in Bldg. 825, 1843, and 1865 Armory s. The Panels (two AES-1500 s and one ACS V5) need to be replaced with upgraded devices with Windows 10/VR 22 firmware. All sensors/keypads/duress buttons need to be upgraded to the newest approved device as specified in the Non-Nuclear Configuration Management Database Equipment Approval letter from AFSFC/FP (CMD) and must have tampers on the individual devices and the tamper programmed as an alarm point. All alarm points will be a single alarm point with no daisy chaining of alarms. These upgraded systems will need to be integrated into the current Security Forces Head end IDS system that reports to Base Defense Operations Center (BDOC) and the Alt BDOC. All Network/IDS cabling will need to be replaced and run in conduit (if not already), and all Junction Boxes or Splice Points will need to have a tamper and alarm.
From Solicitation posted on Jun 26, 2025The 20 Security Forces Squadron is replacing the current Honeywell Vindicator Intrusion Detection System (IDS) in Bldg. 825, 1843, and 1865 Armory s. The Panels (two AES-1500 s and one ACS V5) need to be replaced with upgraded devices with Windows 10/VR 22 firmware. All sensors/keypads/duress buttons need to be upgraded to the newest approved device as specified in the Non-Nuclear Configuration Management Database Equipment Approval letter from AFSFC/FP (CMD) and must have tampers on the individual devices and the tamper programmed as an alarm point. All alarm points will be a single alarm point with no daisy chaining of alarms. These upgraded systems will need to be integrated into the current Security Forces Head end IDS system that reports to Base Defense Operations Center (BDOC) and the Alt BDOC. All Network/IDS cabling will need to be replaced and run in conduit (if not already), and all Junction Boxes or Splice Points will need to have a tamper and alarm.
From Solicitation posted on Jul 21, 2025Notice history
2-
-
Solicitation LATEST Posted Jul 21, 2025No changes from previous notice